• Use the mounting screws to force-fit the secondary sections to the machine bed.
Note
Hole in the machine bed
The shaft of the bolts, which are used to attach the secondary section to the machine base
may not reach the thread.
• If necessary, you must lower the relevant hole in the machine bed.
The letter "N" is to be found on each secondary section. Ensure that the letter "N" on each of
the secondary sections is pointing in the same direction, as shown in the following figure.
Figure 5-7
Screw on the secondary sections in the specified sequence as shown in the following figure.
Figure 5-8
5.3.6.2

Installing the secondary section cover

Risk of cutting injuries when handling secondary section covers
Secondary section covers have sharp edges. When delivered, the rolled up cover bands for
secondary sections are secured using straps that are under spring tension.
If you cut through these straps, then the rolled up cover bands can suddenly unroll. You can
incur cutting injuries at your hands and eyes if you do not wear safety gloves and adequate eye
protection.
• Always wear safety gloves when handling secondary section covers
• Always wear suitable eye protection when unpacking cover bands
• Work in pairs where necessary
• Firmly hold the rolled up cover bands when cutting through the straps
• Allow the cover bands to slowly unroll
Naturally-Cooled 1FN3 Linear Motors
Operating Instructions, 06/2023, A5E52220465B AB
Position of the "N" mark on secondary sections of the 1FN3 product family
Screwed joint sequence of 1FN3 secondary sections
WARNING
5.3 Procedure when installing the motor