Dear customer, Congratulations on your choice and thank you for purchasing one of our appliances. This practical, modern and functional appliance is manufactured using materials of the highest quality which are subject to strict quality control checks throughout the entire manufacturing process.
Safety considerations For your safety If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store articles on or against this appliance. Do not store flammable material near this appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation.
Page 5
Important. When using a very large pot, leave a gap of at least 50 mm (2”) to avoid damaging any parts in bench top wood, plastic or other non-heat resistant materials. Never leave oil or hot fat unattended. The surfaces on heating and cooking appliances get hot when in use.
Installation Statutory This installation must conform with the following: requirements Manufacturer’s Installation instructions Ø Local Gas Fitting Regulations Ø Municipal Building Codes, Ø Refer to AS/NZS 5601.1 for Gas Installations. Ø S.A.A. Wiring Code Ø Local Electrical Regulations Ø Any other statutory regulations Ø...
Before connecting the unit, check whether the local connection conditions (type of gas) are compatible with the unit’s setting. Observe any special conditions imposed by local suppliers (utilities). The specifications of this cooktop are stated on the data label located on the bottom of the cooktop base.
Installation of cooktop Installation procedure: Side clearances: If the distance measured from the into the kitchen bench periphery of the nearest burner to any vertical surface is less than 200 mm, the surface shall be protected in accordance with clauses 6.10.1.2 of AS/NZS 5601.1 1.
Page 9
The cooktop must be connected to the gas supply with upstream connection of an isolation valve in accordance with the respectively valid regulations. We recommend that the isolation valve be fitted prior to the cooktop to enable isolation of cooktop from gas supply. The valve must be easily accessible at all times.
fittings must be used and all connections tested for gas leaks. The supply connection point shall be accessible with the appliance installed. WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an underbench oven. Before Leaving- Check all connections for gas leaks with soap and water.
Changing the nozzles - Remove the pan supports, burner covers and diffusers.Fig. 7. of the burners on the Fig. 7 cooktop - Change the nozzles using the spanner provided by our Service Centre (code 340847, for double and triple flame burners code 340808), taking special care to ensure that the nozzle does not fall when it is removed from the burner or when fitted.
Page 12
and back a few times. To adjust the minimum flame position for ULPG the screw must be fully tightened down clockwise. If the by-pass screw cannot be accessed, disassemble the grease splash tray, which is fixed to the rest of the hob using a clip and screw mounting system.
Operating instructions Burner locations Pan supports Control knobs Auxiliary burner (up to 1 kW) Semi-rapid burner (up to 1,75 kW) Rapid burner (up to 3 kW) Dual double-flame wok burner (up to 5 kW) The gas burners There are indications to show which burner each control knob operates.
Switching on If your cooktop can be switched on automatically (ignition sparkers): automatically 1. Press the chosen burner control knob and turn it anticlockwise to the maximum power setting. While the control knob is still pressed down, sparks are produced on all burners. The flame ignites (it is no longer necessary to press down the control knob).
Outer flame on minimum, inner flame on full power. Inner flame on full power. Inner flame on minimum power. Warnings It is normal to hear a slight whistling noise while the burner is operating. When it is first used, it is normal for the burner to give off odours;...
Important: The use of a cooktop leads to the production of heat and moisture in the kitchen. For this reason make sure that the room is properly ventilated. Keep natural ventilation openings, such as windows, open or provide a mechanical ventilation device (e.g. a range hood or overhead exhaust fan).
Cooking recommendation Very high, high Medium Wok burner Boiling, grilling, Reheating and keeping things hot: browning and cooked and pre-cooked dishes. Asian food (wok). Rapid burner Steaks, omelettes, Rice, white sauce Steaming and frying. and ragout. vegetables. Semi-rapid burner Steaming potatoes, Reheating, keeping things hot and fresh vegetables, making tasty casseroles.
Precautions for use The following advice is intended to help you save energy and prevent pan damage: Use pans which are the right size for each burner. Do not use small pans on large burners. The flame should not touch the sides of the pan. Do not use damaged pans, which do not sit evenly on the cooktop.
Cleaning and maintenance Cleaning Once the appliance is cool, use a sponge to clean it with soap and water. After each use, clean the surface of the respective burner parts once they have cooled down. If any residue is left (baked-on food, drops of grease etc.), however little, it will become stuck to the surface and more difficult to remove later.
Service DO NOT MODIFY THIS APPLIANCE. Only authorized personnel from the Service Centre are qualified to work on the appliance. Sometimes certain faults detected can be easily resolved. Before calling the Service Centre, bear in mind the following advice: Fault Possible cause Solution The general electrical...
Wiring diagram A. Switch B. Blue wire C. Brown wire D. Terminal E. Ignition module www.siemens-home.com CIF: A-28-893550 Siemens-Electrogeräte GmbH E-Nr: EC945RB91A UL PG Gas type Test point pressure (kPa) 2,75 Injectors marks Centre 85/140 46/71 45,40 43,50 HGC (MJ)