Chapter 11 FXYBX/SXYBX
The ground terminal for the Whipover cable type is provided on the end face of
the X-axis wiring box. (Refer to Fig. 11-5.)
2-2
Ground wire
Use an AWG14 (2.0mm
Crimp an M4 ring-tongue terminal on the end of the wire connected to the robot.
2-3
Wiring methods (Cable carrier type)
!
Accurately insert the lock washer between the ring-tongue terminal and robot.
Proper continuity may not be secured if the lock washer is dislocated.
!
Take care not to catch the harness and ground wire from the X-axis with the
cover of X-axis wiring box when installing the cover.
Fig. 11-5 Whipover cable type
2
) or larger ground wire with a total length of 1m or less.
CAUTION
CAUTION
Get other manuals https://www.bkmanuals.com
11-4
Ground terminal