Overview of Cisco MDS 9124V-K9 Switch
Indicator
STATUS:
Status LED
(front panel of
the chassis)
FAN: Fan
status
(front panel of
the chassis)
PSU Voltage
Status LED
(faceplate of
each PSU)
Function
Color
System
Green
Status
Orange
Red
Fan Health
Green
Red
Voltage
Green
Status
Status
State
Solid On
All diagnostics have passed, Cisco NX-OS
is running and the system is operational.
Solid On
Any of the following conditions exists:
• The system is running bootup
diagnostics.
• The system is booting.
• A minor temperature threshold is
exceeded.
Blinking
Mismatched airflow direction in one of the
following modules:
• Fan modules—The switch will shut
down in 10-15 seconds.
• PSUs—The switch will shut down
after 10 minutes.
• Fan modules and PSUs—The switch
will shut down after 10 minutes.
Solid On
One of the following conditions exists:
• A diagnostic test failed or another fault
occurred during bootup.
• A major temperature threshold is
exceeded.
Solid on
All chassis fan modules are operational.
Solid on
A chassis fan module had failed.
Off
No input to the PSU.
Solid on
PSU output is OK.
Blinking
PSU output is not OK, but input is OK.