Sony ECM-MS2 - Electret Condenser Microphone Manual

Features

  • MS stereo for natural sound tone and localization
    MS stereo captures the surrounding sound field reliably with natural sound tone and localization.
  • Monaural recording support
    Monaural recording is supported simply by not connecting the R channel cable.
  • Strong wind screen attached for strong winds
    Reduces noise caused by strong winds in outdoor and other affected environments.
  • Compact and lightweight
    Length of 137 mm and mass of 160 g, making it easy to use and carry.
  • External power supply type
    Supports 40 V to 52 V DC external power supply.

Names and Functions of Parts

Names and Functions of Parts

  1. Microphone
    When mounting the microphone on a camcorder, make sure that the "UP" mark on the microphone's label is facing up.
  2. Output connectors (XLR-3-12C type) (white: L channel, red: R channel)
    Outputs the sound captured by the microphone. It also supplies power from the external power supply.
  3. Wind screen
    Attach to the microphone to reduce wind and breathing noise.
  4. Cable tie
    Use this to bundle and fasten the microphone cable.

Sound Pickup Mode

The sound pickup mode is determined by the power supply status from an external device to the L and R channels, or by the sound pickup mode configured on the camcorder, as shown in the following table. If the R channel connector is not connected, sound pickup will be in monaural mode.

Sound pickup mode Power supply to L and R channels / camcorder setting
Stereo L: ON; R: ON / Stereo
Monaural L: ON; R: OFF / Mono

Stereo mode

Stereo mode - Directivity
Directivity

Stereo mode - Frequency response diagram
Frequency response diagram

Monaural mode

Monaural mode - Directivity
Directivity

Monaural mode - Frequency response diagram
Frequency response diagram

For details on menu operations on the camcorder, refer to the operation manual supplied with the camcorder.

Power Supply

This microphone is powered only from an external supply. Connect the output connector of the microphone to an external power supply device, such as a Sony AC power supply or equivalent device, or the microphone connector of an audio mixer or camcorder.

Notes

  • Before connecting the microphone to a camcorder or other device, check that it is equipped with a 40 V to 52 V microphone input connector.
  • An unbalanced cable cannot be used with this microphone. Be sure to use a balanced microphone cable.

Notes on Use

  • Microphones are delicate. Do not drop, hit, or subject it to excessive shock.
  • Avoid extended usage or storage in high humidity or temperatures above 60°C (140°F).
  • If acoustic feedback occurs during use (a howling sound is heard from the speakers), point the microphone away from the speakers or increase the distance between the microphone and the speakers.

Specifications

Type Electret condenser microphone
Stereo type MS (Mid-Side) stereo microphone
Power supply External power supply 40 V to 52 V DC (IEC 61938 P48)
Current consumption Stereo: 3 mA or less × 2 channels Monaural: 3 mA or less
Output connector XLR-3-12C type (2)
Dimensions ø24 × 137 mm (ø31/32 × 5 1/2 in.)
Mass Approx. 160 g (5.6 oz.)
Supplied accessories W ind screen (1), cable tie (1), Operating Instructions (1), warranty booklet (1)
Frequency response Stereo: 80 Hz to 20,000 Hz
Monaural: 70 Hz to 20,000 Hz
Directivity Unidirectional
Output impedance 30 Ω ± 20% (1 kHz), balanced
Sensitivity (typ) Stereo: −32 dB1) (25.1 mV)
Monaural: −36 dB1) (15.8 mV)
Signal-to-noise ratio 69 dB (typ) (IEC 179 A-weighted, 1 kHz, 1 Pa)
Inherent noise 2 5 dB SPL (typ)2)
Wind noise3) 45 dB SPL or less (with wind screen)
65 dB SPL or less (without wind screen)
Maximum input sound pressure level 125 dB SPL (typ) (input level for 1% output signal waveform distortion at 1 kHz, converted into equivalent sound pressure level)2)
Dynamic range 100 dB (typ)
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature −20°C to +60°C (−4°F to +140°F)

1) 0 dB = 1 V/Pa, 1 kHz
2) 0 dB SPL = 2 × 10−5 Pa
3) Wind noise is the value measured by applying a wind velocity of 2 m/s (6.6 ft/s) to the microphone from all directions. The noise output mean value is converted to the equivalent input sound pressure level (0 dB SPL = 2 × 10−5 Pa).

Design and specifications are subject to change without notice.

Note
Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Sony ECM-MS2 - Electret Condenser Microphone Manual

Advertisement

Need Assistance?

Do you have a question about the ECM-MS2 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents