2.

Description and Operation

2.1

Overview

This chapter contains terms and concepts related to safety and the application of the FF-LS Series miniature safety light
curtain. The importance of the installer's role in the set-up and installation of the machine guarding systems is discussed.
This section also contains device identification and specification information.
2.2

Description

2.2.1 Control and Sensing Unit

The FF-LS Series safety light curtain is an infrared multi-beam device designed to protect operators working on
dangerous machines. Entering the invisible sensing field causes the light curtain output contacts to open.
emergency stop condition is then sent to the machine control circuitry. Detection of the operator body parts will lead to
the immediate stoppage of the moving parts of the machine.
The FF-LS Series device consists of a control unit connected to a pair of sensing units. Each sensing unit is made
up of a row of emitting circuits alternating with receiving circuits. These circuits are contained in an extremely small
aluminum housing. The 1.18 in (30 mm) resolution device has a housing cross section of 0.47 x 0.78 in (12 x 19.7
mm); the 0.55 in (14 mm) resolution has a cross section of 1.38 x 0.91 in (35 x 23 mm).
The control unit supplies power to the sensing units, monitors correct system operation and transmits the stop signal to the
machine control circuitry via its two output relays.
The light curtain may be operated in one of two different modes.
automatically after powering up or after any intrusion into the sensing field. In the start/restart interlock mode (manual),
the operator must press an external push button connected to the terminal strip of the control unit to restart the light
curtain. The mode of operation is selected via an internal selector switch located in the control unit.
The control unit has a test input that is used to trigger the output relay switching and check the correct operation of the final
switching devices. For troubleshooting, the control unit provides optical and acoustic signals to help perform diagnostics.
Permanent self-checking is based on microprocessor technology and meets the requirements of EN 61496 (replaces EN 50
100) - part 1 & 2 European standards for type 4 electrosensitive protective equipment. This technique has been examined
by TÜV of Hannover who granted the EC-type examination certificate.
The FF-LS Series safety light curtains are ideal for the protection of workstations on small machines such as paper-cutting
machines or pick-and-place robots.

2.2.2 Unit Compatibility

INCOMPATIBILITY OF FF-LS SERIES SAFETY LIGHT CURTAIN UNITS
• The control unit and the sensing units (A and B) are delivered as a set and are preset (same number of beams). Each of
the units in a set has a red label on its housing with the same number that specifies the number of beams in the sensing
field.
• Ensure the number on the red label is the same for each of the three units in a set.
• Ensure the serial numbers on the sensing units A and B are the same.
Failure to comply with these instructions could result in death or serious injury.
The two sensing units A/B are matched to each other by individual coding. Therefore, only connect a matched pair of
sensing units A/B (each has the same serial number) to a control unit. Failure to comply with these instructions will result in
improper product performance.
107022-14 EN FR26 GLO 0100 Printed in Germany
In the automatic mode, the device restarts