Replace Power Supply Components
Step 12
Verify that the Fabric LED for the slot that you specified turns on. Also, you can verify that the module is in
power on state by running the show platform command to verify the status of the module to be
POWERED_ON.
Since the Fan trays are blocking the view, fabric module LEDs might not be visible. Therefore, you can verify
the fabric module LEDs status using show led location 0/FClocation command.
Replace Power Supply Components
The Cisco Nexus 9800 series switches support OIR of power modules. If you are replacing a redundant power
module, you can replace the power module while the system remains powered on without any electrical hazard
or damage to the system. This feature enables you to replace a power module while the system maintains all
routing information and ensures session preservation.
However, to maintain operational redundancy and proper cooling, and to meet EMI compliance standards,
you must have at least one working redundant power module that is installed. When you remove a failed
power module with the switch in operation, perform the replacement as quickly as possible. Make sure you
have the replacement power module ready before beginning the removal and installation procedure.
Note
This section contains procedures on how to replace the power modules.
Caution
Install Power Shelf Bezel
Follow these steps to install a power shelf bezel on a chassis:
Procedure
Place the power supply bezel as shown in the below figure and secure it with the provided jackscrews.
Cisco Nexus 9808 NX-OS Mode Switch Hardware Installation Guide
92
For the RP to communicate properly to a power module in a power tray, input power to at least one of the
power modules in the power tray should be present.
Do not turn off the switch on the power tray to remove individual power modules. Power modules support
OIR, so they can be removed and replaced with the power on and the system operating.
Replace Chassis Components