hit counter script
Download Print this page
Honeywell C7110C1001A Quick Start Manual

Honeywell C7110C1001A Quick Start Manual

Excel 5000 open system wall modules

Advertisement

Quick Links

HONEYWELL EXCEL 5000 OPEN SYSTEM
GENERAL
The C7110C1001A and C7110D1009A are combined CO
temperature wall modules designed for applications in indoor
ventilation and air conditioning systems. In conjunction with
the Honeywell's Excel 5000 controllers, they can be used to
control the flow of incoming fresh air, thus improving air
quality while reducing energy consumption. During high-
occupancy periods, fresh air can be supplied to rooms in
order to maintain acceptable air quality, while during low-
occupancy periods, the unnecessary conditioning of outdoor
air can be avoided or reduced.
FEATURES
Fully compatible with the Excel 5000 controllers.
CO
sensor employing state-of-the-art Non-Dispersion
2
Infrared (NDIR) technology.
Selectable CO
measurement range of 400...2000/3000
2
ppm.
Self-calibrating: automatic drift correction (ABC
algorithm) based on long-term evaluation.
External LED (C7110C1001A: CO
C7110D1009A: auxiliary)
Internal Service LED (visible after removing cover and
setpoint wheel).
® U.S. Registered Trademark
Copyright © 2017 Honeywell Inc.  All Rights Reserved
C7110C1001A / C7110D1009A
MODELS
order no.
C7110C1001A
C7110D1009A
/
2
DIMENSIONS
level indication;
2
WALL MODULES
description
 0...10 VDC CO
 0...10 VDC temperature output
 CO
level indication LED
2
 Service LED
 0...10 VDC CO
 NTC20kΩ temp. sensor (passive)
 Temp. setpoint wheel (rel./abs. scale)
 Occupancy bypass button
 Auxiliary LED
 Service LED
External LED
CO2 LEVEL INDICATION LED (C7110C1001A)
AUX. LED (C7110D1009A)
OCCUPANCY BYPASS
BUTTON (C7110D1009A)
99
Fig. 1. Dimensions in mm
PRODUCT DATA
sensor output
2
sensor output
2
30
EN0B-0735GE51 R0317

Advertisement

loading

Summary of Contents for Honeywell C7110C1001A

  • Page 1 In conjunction with External LED the Honeywell's Excel 5000 controllers, they can be used to CO2 LEVEL INDICATION LED (C7110C1001A) control the flow of incoming fresh air, thus improving air AUX.
  • Page 2: Technical Data

    C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA TECHNICAL DATA MOUNTING General WARNING Power supply (terminals 24 VAC ± 20%; 50/60 Hz or 1+3) 24 VDC ± 30%; 1.5 W Risk of electric shock or equipment damage! Power-up time ≤ 60 sec (incl. self-diagnostics) Do not touch any live parts.
  • Page 3 "2000" ppm (see Fig. 9) – or to any other position except "3000" ppm (see Fig. 6) – the CO measuring range is 400…2000 ppm. LINE LINE VOLTAGE VOLTAGE Fig. 4. Wiring C7110C1001A to controller and separate safety transformer EN0B-0735GE51 R0317...
  • Page 4 C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA "3000" ppm Fast Background Calibration ("CAL400") Fig. 6. Jumper set to 3000 ppm Fig. 8. Jumper set to CAL400 When the configuration jumper is set to position "3000" ppm When the configuration jumper is set to position "CAL400"...
  • Page 5: Service Led

    C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA (i.e., far below 400 ppm) may prevail, especially in Configuration Potentiometer new, poorly ventilated areas. To prevent sensor The wall module features a configuration potentiometer malfunctions in such situations, it is recommended (accessible only after removing the top cover and, in the case that ABC be switched OFF.
  • Page 6 C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA The "Sensor Output" Mode The "Relay Output" Mode In the "Sensor Output" mode (analog), the Service LED (see In the "Relay Output" mode (digital), the Service LED (see Fig. 12) is always dark.
  • Page 7 C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA TEMPERATURE SENSOR (C7110D1009A, ONLY) Table 1. Temperature sensor accuracy ambient nominal max. error temperature resistance (Ω) 15.5 °C (60 °F) ±0.29 °C (±0.52 °F) 31543 18.3 °C (65 °F) ±0.27 °C (±0.49 °F) 27511 21.1 °C (70 °F)
  • Page 8 C7110C1001A, C7110D1009A WALL MODULES – PRODUCT DATA OCCUPANCY BYPASS BUTTON AND Example LED Behaviors AUXILIARY LED (C7110D1009A, ONLY) Auxiliary LED Indicating Override When the auxiliary LED of the C7110D1009A has been NOTE: The functionality of the occupancy bypass button configured to indicate an override, it can display various and the corresponding behavior of the auxiliary LED different behaviors, e.g.:...
  • Page 9: Connection Terminals

    1 2 3 4 5 6 7 CONNECTION Fig. 17. Mounting the T7460-LONJACK Manufactured for and on behalf of the Environmental & Energy Solutions Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Home and Building Technologies Honeywell GmbH Böblinger Strasse 17...

This manual is also suitable for:

C7110d1009a