Quick Start Guide
AC Power
Adapter
Control Center
1 2 3 4
1
2
3
4
Armed Power
Zone
4 "AAA" Batteries
+
+
+
+
(Not Included)
Recommended
for back-up
situations
-
-
-
-
Zones 1,2, & 3 - Activating HOME or AWAY Mode
Armed/Alarm Mode
Alarm System
- Only Sensors in Zones 1, 2, 3 will trigger alarm
- Arm/HOME - Instant alarm
- Arm/AWAY - Delay ALARM allows for exit
and re-entry
Note: Motion Sensor will only trigger
alarm in AWAY Mode
1 2 3 4
Arm
1
2
3
4
Armed
Power
Zone
Zones
Armed
Zone 1, 2, & 3 Visual/Audio Alert
Notification Mode
- Only Sensors in Zones 1, 2, 3
will activate notifications
- Select from visual alert, single chime or
continuous alert (beeping) when Sensor
is activated
Example
Three Mode settings
Zone 1 - Front door
"Alert" - Continuous Tone
Zone 2 - All windows
"Chime" - Single Tone
Zone 3 - Gates & sheds
"Off" - Lights only
1 2 3 4
Arm
1
2
3
4
Armed Power
Zone
Zones
Silent Alert
Adding a Silent Alert
Install batteries
Step 1 - Press and hold the "Learn"
button on inside of the Silent Alert.
The LED's will begin to flash
Step 1
Step 2 - Press and hold the "Mute"
button on the Control Center for
three seconds. The Control Center
will sound 5 beeps, release "Mute" button
If the Silent Alert is in range, the LED's will
stop flashing. This indicates the Silent Alert
has been added to the Control Center.
Creating a new security code
Step 1 - On the Control Center press and hold
the "Learn" button, then press and hold the
"Arm" button together until a long beep sounds.
Release buttons, the green power button will
begin to flash.
Step 2 - Enter the current code (default is 1234)
Step 3 - Enter new code
Step 4 - Re-enter new code to confirm
Arm
1
2
Zone
HOME Mode
Step 1 - Enter four digit Security Code
Step 2 - Press and Hold "Arm " button
button until the Armed LED indicator turns on
Note: Motion Sensors do not operate in
HOME Mode
To disarm Alarm, enter four digit
Security Code. The Armed LED
indicator will turn off.
1
Zone
Zones
Zone 4 - Alert Only
Dedicated Alert Mode
Zone 4 is designed to continuously monitor
select areas. Sensors assigned to Zone 4 will
immediately and automatically start
monitoring. No special settings are required.
Note: Zone 4 is not controlled by Notification Mode
switch, and does not activate alarm
& back door
Examples - water heater, garage door, back gate
Input DC 12V
-
+
Mute
Learn
Notification
Alert
Chime
switches
1
2
Off
Zone
Alarm Siren
Adding an Alarm Siren
Plug-in AC Adapter
Step 1 - Press and hold the "Learn"
Step 2
button on inside of the Alarm Siren.
The LED's will begin to flash
Bottom of
Alarm Siren
Input DC 12V
-
+
Mute
Mute
Learn
Alert
Chime
Off
Input DC 12V
-
+
Mute
Mute
Learn
Alert
Chime
Off
The Control Center operates in three ways:
Armed/Alarm Mode | Notification Mode | Dedicated Alert Mode
Step 2
Step 3
Step 4
Input DC 12V
-
+
Mute
Learn
1 2 3 4
Arm
Alert
Chime
3
4
Armed Power
Off
Step 1
Step 2
1 2 3 4
Arm
2
3
4
Armed Power
1 2 3 4
Arm
3
4
Armed Power
Zone
On/Off
Learn
AC Adapter
Step 2 - Press and hold the
"Mute" button on the Control
Center for three seconds. The
Control Center will sound 5
beeps, release "Mute" button
If the Alarm Siren is in range
the LED's will stop flashing.
This indicates the Alarm Siren
has been added to the
Control Center.
Add a Sensor to any Zone
Step 1 - Press and hold the "Learn" button,
for three seconds, the Control Center will
sound a long beep. Release the button.
Step 2 - Select the Zone number, the
Zone LED will begin to flash.
Step 2
1 2 3 4
Step 1
1
2
3
4
Zone
Learn
Step 3 - Activate the Sensor
AWAY mode
Step 1 - Enter four digit Security Code
Step 2 - Press "Arm" button twice. The Armed
LED indicator begins flashing. You have 45
seconds to exit before Alarm is active
To disarm Alarm, enter four digit
Security Code. The Armed LED
indicator will turn off.
1 2 3 4
1
2
3
4
Zone
Zones
Sensors in Zone 4
- When a Sensor is activated, the amber
LED will flash and a continuous 4 beeps
will sound.
- To temporarily stop Alert (beeping) once
Sensor has been activated, press "Mute"
button on Control Center.
- Sensor must be closed (i.e. door closed,
water leak stopped) to discontinue Zone
4 notification
1 2 3 4
1
2
3
4
Zone
Zone
Zone indicators - Each number indicates a unique
zone. Each Zone can hold up to four Sensors. Any
combination of Sensors types can be assigned to
any of the four Zones.
Learn Button - Used to link Sensors and
Accessories to the Control Cneter. Also sed to
Step 1
change the Security Code.
Number Buttons - Used to assign Sensors to Zone,
bypass Zones, and Arm/Disarm Alarm.
Mute Button - Used to silence the Notification Alert.
Also used to send test signals to accessories.
ARM Button - Used to ARM/DISARM. Also used for.
Also used for changing the Security Code.
See User's Manual for more information.
Choice
Choice
ALERT
ALERT
45129
Step 1
Input DC 12V
-
+
Mute
Learn
Learn
Arm
Step 3
Alert
Chime
Armed Power
Off
Garage Door
Sensor
Window/Door
Sensor
Step 1
Step 2
Arm
Armed
Power
Armed
Input DC 12V
-
+
Mute
Mute
Learn
Arm
Alert
Chime
Off
Armed Power
Easy wireless
alert products
for any budget!

Advertisement

loading

This manual is also suitable for:

Choice alert 45129