Running Power Supply Tests
Enter the show power-supply command.
SFS-7000P# show power-supply
=====================================================================
=====================================================================
ps
---------------------------------------------------------------------
1
2
Specify the type of test (self-test is chosen by default) by entering the diag
Step 2
power-supply id command.
SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag power-supply 2
SFS-7000P(config-diag-power-supply-2)# test self-test
Start the test.
Step 3
SFS-7000P(config-diag-power-supply-2)# start
Display the progress of the test by entering the show diag fan command.
Step 4
SFS-7000P(config-diag-power-supply-2)# exit
SFS-7000P(config)# exit
SFS-7000P# show diagnostic power-supply
======================================================================
======================================================================
report : Passed=1, Failed=0, Total=1
Display any errors that appear in the result string by entering the show diag
Step 5
fru-error command.
SFS-7000P# show diag fru-error
================================================================
================================================================
Cisco SFS 7000P Hardware Installation Guide
5-8
type
admin-status
AC
up
AC
up
Diagnostic Tests For Power Supply
module-type : power-supply
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Power Supply Self Test Completed, Final
Chapter 5
Power-supply Information
oper-status
utilization
up
n/a
up
15
Fru-Error
Hardware Diagnostic Tests
voltage
48
47
OL-9167-01 Rev. A0