Operation Manual / 4 Product description / A100-M axial
8 Disassembly and assembly / 8.11 Installing the compressor casing
Turning and moving in wall insert
Fig. 56: Turning and moving in wall insert
1. Secure the lifting device (90190 / 90195) and the fixing segment (90192) to the flange of
the wall insert (77000) using the screws (90197) and washers (90198).
Carefully turn wall insert (77000) with fitted diffuser over the support angle (90025) and
pull up vertically.
2. Remove support angle (90025), screws and nuts.
3. Fit guide studs (90319).
4. Carefully install the wall insert (77000) in the compressor casing. Make sure both mark-
ings are in the correct position.
© Copyright 2020 ABB. All rights reserved.
HZTL4033_EN
Rev.F
August 2020