3. MODEL NAME SETTING METHOD WHEN ENGINE IS REPLACED
Required equipment:
• Remote controller (RMT-D251O/D251P)
• Service remote controller (Part code: J-6090-203-A)
• Monitor
Model name delete method
1.
Turn the main POWER ON.
2.
Press the following buttons on the service remote controller in this order.:
"ESC" k "CHAP" k "1"
* Confirm that the above operation is performed in the state that the screen has exited all settings such as "Home Menu" or "Simple
Setting".
3.
Turn the main POWER OFF.
4.
Turn the main POWER ON.
5.
Find out the tentative model name from the Correspondence Table (Table 1) for the client machine. Then, enter the 4-digit "Input No."
on the screen using the service remote controller.
6.
The model name setting method is complete. (Screen disappears.)
* Upon completion of the model name setting, be sure to press both "ENTER" and "3" simultaneously on the service remote controll er
without fail. It sets the remote control code "3".
Table1 Correspondence table between tentative model name and final product name
Model name
RDR-HXD790
RDR-HXD795
RDR-HXD890
RDR-HXD895
RDR-HXD990
RDR-HXD995
RDR-HXD1090
RDR-HXD1095
[Symptom]
If the following operation is performed, set won' t be able to be restored.
[Remedy]
Must not be performed the following operation using service remote.
If it is performed, set won't be able to be restored.
And if set is broken by the operation, we can't guarantee the set when
pressing in order of the following button.
* [ESC]--> [STEREO]
([ESC]--> [Any button which is not described in SM])
AEP1
AEP2
MRX-1740/EC1
—
—
MRX-1745/EC2
MRX-1760/EC1
—
—
MRX-1765/EC2
MRX-1770/EC1
—
—
MRX-1775/EC2
MRX-1780/EC1
—
—
MRX-1785/EC2
Tentative model name
AEP3
MRX-1740/EC1
MRX-1740/CEK
—
MRX-1760/EC1
MRX-1760/CEK MRX-1760/AU2
—
MRX-1770/EC1
—
MRX-1775/CEK
—
—
MRX-1785/CEK
Service remote controller
(Part code: J-6090-203-A)
1-2
UK
AUS
—
—
—
—
—
—
MRX-1770/AU2
—
—
—
—