v If your system has four power supplies, plug E1 and E2 to PDU A and E3 and E4 to PDU
B.
Note: Confirm that the system is in standby mode. The green power status indicator on the
front control panel is flashing, and the dc out indicator lights on the power supplies are
flashing. If none of the indicators are flashing, check the power cord connections.
3. Wait for the green light on the control panel to start flashing.
4. Ensure that your ASCII terminal is set to the following general attributes.
These attributes are the default settings for the diagnostic programs. Be sure that your terminal is set
according to these attributes before proceeding to the next step.
Table 2. Default settings for the diagnostic programs
General setup attributes
Line speed
Word length (bits)
Parity
Stop bit
5. Press a key on the ASCII terminal to allow the service processor to confirm the presence of the ASCII
terminal.
6. When the login display appears for the ASMI, enter admin for the user ID and password.
7. Change the default password when you are prompted.
8. Press Enter until the server information appears. You have completed the setup for an ASCII terminal,
and have started the ASMI.
9. Continue with "Completing the server setup" on page 18.

Cabling the server to the HMC:

The Hardware Management Console (HMC) controls managed systems, including the management of
logical partitions, the creation of a virtual environment, and the use of capacity on demand. Using service
applications, the HMC can also communicate with managed systems to detect, consolidate, and forward
information to IBM service for analysis.
Before you begin
If you have not installed and configured your HMC, do so now. For instructions, see Installation and
configuration tasks(http://www.ibm.com/support/knowledgecenter/POWER9/p9hai/
p9hai_taskflow.htm).
To manage POWER9 processor-based systems, the HMC must be at version 9 release 1 or later. To view
the HMC version and release, complete the following steps:
1. In the navigation area, click Updates.
2. In the work area, view and record the information that appears in the HMC Code Level section,
including the HMC version, release, Service Pack, build level, and base versions.
To cable the server to the HMC, complete the following steps:
12
Power Systems: Installing the IBM Power System S922L (9008-22L)
3151 /11/31/41
3151 /51/61
settings
settings
19,200
19,200
8
8
No
No
1
1
3161 /64
settings
Description
19,200
Uses the 19,200 (bits per second) line
speed to communicate with the system
unit.
8
Selects 8 bits as a data word length
(byte).
No
Does not add a parity bit and is used
together with the word length attribute
to form the 8–bit data word (byte).
1
Places a bit after a data word (byte).