LED FLAT LIGHT
53W/60W
User Manual
• Please read the 「Safety
Precautions」
prior to use for your safety.
•Thismanualisintendedtopreventproductdamageandprotecttheuser'ssafety.
•Placethemanualataplacewhereitcanbeeasilylocatedbyallpotentialusers.
WARNING
Turn power off before installation.
Do not randomly connect the power
polarities.
• R iskofelectricshock.
• R iskofproductdamageandaccidents.
Do not store in a humid area.
Must use woodscrews provided by
LG Electronics during installation.
• R iskofproductmalfunctioning.
• R iskofproductfallingandinjuryto
user.
Do not install near potential
Do not use the product if impurities
sources of fire or inflammable
are present in the product or if the
objects, such as paper or cloth.
product is submerged.
• R iskofproductmalfunctioningand
• R iskofaccidentssuchaselectricshock
accidents.
and product damage.
Must fix the product properly
Must have at least two or more
on the ceiling.
people working during installation.
• R iskofproductdroppingandcausing
• R iskofproductdroppingandcausing
injury to the user.
injury to the user.
Do not disassemble or arbitrarily
If the lamp turns off by itself, do not
remodel the product. Do not use for
disassemble the product. Contact
underwater lighting purposes.
your local LGE sales representative
(Underwater landscape, searchlight,
for repair.
fishing, events, etc.)
• R iskofelectricshockandproduct
• R iskoffireandelectricshocks.
malfunctioning.
LED FLAT LIGHT
LED FLAT LIGHT is a product with enhanced efficiency and user convenience achieved through its energy
management and control technology and ultra-thin design. It is high-efficiency lighting capable of
replacing existing lighting devices such as fluorescent lamps, etc.
Advantages
High efficiency reduces energy costs
Replacing existing lighting devices with the LED FLAT LIGHT can reduce energy costs by 30% or more.
70%
34% -
increase in energy e ciency
LG's test standards
※
Dimming control provides additional energy reduction costs
Dimming control utilizing an illumination intensity sensor reduces electricity usage, thereby
providing approximately 70% energy reduction.
Reduction in electric energy usage
Dimming control system
Light control application provides energy reduction
Electricity 80W
Electricity 53W
Electricity 24W
Existing lamp
LED
LED (Dimming control)
This function is provided as an optional part.
※
There may be differences depending on the
conditions of use.
WARNING
Do not stare directly at the lamp
Do not expose the product to water
when turned on.
when cleaning it.
• S tronglightmaycausevisual
• R iskoffireandelectricshock.
impairment.
Do not use for purposes other than
Never disassemble the product.
lighting.
• R iskofaccidentssuchaselectricshock
(Heating food, drying clothes, etc.)
and product damage.
• R iskoffire.
Do not use if the product has been
dropped or exposed to shock.
• R iskofproductmalfunctioning.
If the external flexible cable or cord of this Luminaire is damaged, it shall be exclusively replaced by the
manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
CAUTION
Do not install where it may be
Do not clean the product with
exposed to direct sunlight, humidity,
inflammable substances such as
or dust.
alcohol, benzene, and acetone that
may alter the surface.
Low carbon emissions allows environmentally-friendly lighting
Product is mercury-free, presenting no harm to the environment or human body. Its annual CO
emissions have been dramatically reduced, making it an environment-friendly product.
Comparison of CO
emissions
(unit: kgCO
)
2
2
Has the equivalent e ect
of planting 17 trees
Existing lamp
LG FLAT 53W
If used 12 hours each day for a year
※
Conversion constant 0.573 kgCO
/Kwh, 3.86kgCO
/tree)
※
2
2
Natural light prevents glare
It provides the lowest and best glare level in the industry by producing pleasant, healthy, and
natural light without the use of a louver.
Existing light
LED FLAT LIGHT
Long life expectancy provides low maintenance cost
If used for 12 hours a day, the product can be used for 10 or more years without replacement.
Thus, maintenance costs are low, making it an economically sound option.
Product Configuration and Size
1. Product Configuration
LED FLAT LIGHT is a product with enhanced efficiency and user convenience achieved through
its energy management and control technology and ultra-thin design. It is high-efficiency
lighting capable of replacing existing lighting devices such as fluorescent lamps, etc.
Top Cover
Di user Plate
Bottom Cover
Converter
< 600 x 600 Type >
< 300 x 1200 Type >
2. Product Size
*Unit: mm
Safety Precautions
The meanings of the signs displayed on the product and user manual are as follows:
▶
•
This sign means use caution for dangerous items and operations. For parts with this sign,
2
user must read the manual carefully and follow instructions in order to avoid risks.
This sign is for displaying risks involving electric shock under certain conditions.
•
WARNING
Violation of warnings may lead to serious injury or death.
●
CAUTION
Violation of precautions may lead to light injury or product damage.
●
WARNING
Product is heavy. Use a trolley when
transporting the product.
• D roppingtheproductmaycause
product damage and malfunction.
Do not install product in places
exposed to dampness.
• Riskoffire.
Do not install in areas that have risks
of flooding.
• Riskofelectricshock.
Do not install on un-leveled ceilings.
• R iskofproductfalling,whichmaylead
to product damage and injury to the
user.
Installation
1. T-BAR
•Makesuretoturnoffthemainpowerswitchoftheinstallationspacebeforeconnection.
• C onnectsothatthecolorsofthe3powercablesmatch.
(LIVE: BROWN, NEUTRAL: BLUE, P.E.: GREEN/YELLOW)
Interior wiring
NEUTRAL
of the building
LIVE
P.E.
Product's
power cables
1
2
Drill and prepare the ceiling
Connect the 3 product cables
so the hole is smaller than the
to the interior wiring of the
product.
building. For finishing cap,
use standardized products.
4
5
Place the horizontal product
Ensure the inserted product
into the T-bar.
is horizontal.
T : T -BAR
M : M-BAR
Use with proper rated voltage.
• Riskoffireandproductdamage.
Install a circuit breaker.
• Riskoffireandelectricshock.
Perform grounding work.
• Riskofelectricshock.
Electric work must be performed by a
certified technician according to the
installation manual.
• Inadequate power capacity and faulty electric
work may lead to fire or electric shock.
3
Rotate the connected
product by 20 degrees.
Then insert it into the T-bar
insertion space.
• M akesurethatall4sidesof
the product match the T-bar.
6
Once installation is complete,
turn on the power switch to
check it is operating properly.
• A ftertheinstallationis
complete, remove the