hit counter script
Download Print this page
Hide thumbs Also See for NCS 1004:

Advertisement

Install Cisco NCS 1004
Figure 11: Four Post Slider Identification
1
Slide and adjust the length of the slider arm.
Step 2
Integrate the four post slider with the rack. The procedure for the 23" and 19" rack is discussed here:
• 19" rack - the slider can be directly fitted on to a 19" rack. On the front side, insert only the top most screw of the
slider (48-101524-01) and tighten it to a torque value of 4.65 N-m. On the rear side, insert five screws (48-101524-01)
and tighten them to a torque value of 4.65 N-m.
• 23" rack - the slider is fitted on to a 23" rack using an adapter (refer the following image). The formed surface must
always face the inner side of the rack post. On the front side (towards the chassis), insert only the top most screw
of the slider (48-101524-01) and tighten it to a torque value of 4.65 N-m. On the rear side (towards the chassis),
insert five screws (48-101524-01) and tighten them to a torque value of 4.65 N-m. For the adapter portion which is
towards the rack, all the six screws are fitted on the front and rear side.
Install Four Post Slider into an EIA/ ANSI Rack
Install Cisco NCS 1004
9

Advertisement

loading