8 Measurements and Adjustments
8.1.
Driver Set-up
8.1.1.
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Dynamic
PNR: OFF
Aspect: 16:9
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-149V, Voltage of Vscn is -4V ±4V.
8.1.2.
Adjustments
Adjust driver section voltages referring the panel data on the
panel data label.
Check or adjust the following voltages with the multimeter.
Name
Test Point
Vsus
TPVSUS
(SS)
Ve
TPVE (SS)
Vset
TPVSET
(SC)
Vad
TPVAD (SC) -149V ± 1V
Vscn
TPVSCN
(SC)
Vda
TPVDA (SS) 75V ± 1V, -2V
*See the Panel label.
26
Voltage
Volume
Vsus ± 2V
R628 (P)
Ve ± 1V
VR16000 (SS) *
320V +7V, -9V Fixed
VR16600 (SC)
Vad+145V ± 4V Fixed
Fixed
Remarks
*