Description of the motors
2.3 Derating factors
Calculate the reduced S1 line as follows:
M
S1 red
M
S1 red
M
S1
n
x
d
Figure 2-3
28
(n) = x
• M
(n / x
)
d
S1
d
reduced motor torque for S1 operation at required altitude and ambient
temperature
motor torque for S1 operation at ambient temperature of 40 °C and 1000 m
above sea level (see Chapter "Datasheets and characteristics" in Configura-
tion Manual)
motor speed
derating factor from the table above
Example for derating at ambient temperature of 50 °C and installation altitude of 1000 m
with derating factor 0.91
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 07/2021, A5E50610821B AB