hit counter script
Table of Contents

Advertisement

Quick Links

Power Systems
Installing the IBM Power System E850
(8408-E8E)
IBM
GI11-9913-01

Advertisement

Table of Contents
loading

Summary of Contents for IBM E850

  • Page 1 Power Systems Installing the IBM Power System E850 (8408-E8E) GI11-9913-01...
  • Page 3 Power Systems Installing the IBM Power System E850 (8408-E8E) GI11-9913-01...
  • Page 4 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 39, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ™...
  • Page 5: Table Of Contents

    Installing the IBM Power System E850 (8408-E8E) ....Prerequisite for installing the IBM Power System E850 (8408-E8E) Completing inventory for your server . Attaching the lift handles to the chassis .
  • Page 6 Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 7: Safety Notices

    You should also refer to the safety information documentation any time you do not clearly understand any safety information in the U.S. English publications. Replacement or additional copies of safety information documentation can be obtained by calling the IBM Hotline at 1-800-300-8751.
  • Page 8 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 9 Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 10 DANGER: Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) viii Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 11 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. (L002) (L003) Safety notices...
  • Page 12 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product. Consult the label on each part for laser certification numbers and approval information. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 13 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
  • Page 14 (C048) Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS (Network Equipment-Building System) GR-1089-CORE: The equipment is suitable for installation in the following:...
  • Page 15 Note: All Ethernet cables must be shielded and grounded at both ends. The ac-powered system does not require the use of an external surge protection device (SPD). The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground.
  • Page 16 Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 17: Installing The Ibm Power System E850 (8408-E8E)

    Use the information in this section to understand the prerequisites required for installing the IBM Power System E850 (8408-E8E) system. Note: The IBM Power System E850 (8408-E8E) requires three people to lift the system and install it into a rack.
  • Page 18: Attaching The Lift Handles To The Chassis

    Remove the following components from the front of the system chassis: v System fans v Front bezel v Disk drive backplane Remove the following components from the rear of the system: v Power supplies Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 19: Attaching The Mounting Hardware To The Rack

    3. At the front of the rack, position the left slide rail (C) between the left-side front and rear rack EIA mounting standards as shown in Figure 3 on page 4. 4. Insert the front slide flange locator studs into the front EIA mounting holes. Installing the IBM Power System E850 (8408-E8E)
  • Page 20 R identifier stamped into the inside front location. 9. Attach the two nut clips (F) to relative EIA locations 3b on both right and left front vertical EIA standards as shown in Figure 3. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 21: Removing Components From The System Chassis

    5 seconds. Removing the power supplies Learn how to remove the power supplies. To remove the power supplies, complete the following steps: Installing the IBM Power System E850 (8408-E8E)
  • Page 22: Removing The Front Cover

    To remove the front cover, complete the following steps: 1. Go to the front of the system chassis. 2. Place your fingers on the indentations (B) located on both sides of the cover. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 23: Removing The System Fans

    Learn how to remove the system fans. To remove the system fans, complete the following steps: 1. Rotate the fan handle (A) in the direction shown in Figure 7 on page 8 to unlock the fan from its slot. Installing the IBM Power System E850 (8408-E8E)
  • Page 24: Removing The Disk Drive Backplane

    Learn how to remove the disk drive backplane. To remove the disk drive backplane, complete the following steps: 1. Use the included 4mm Allen hand tool to loosen the 2 captive shipping screws on the RAID assembly. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 25 2. Turn the thumbscrews on the RAID assembly to loosen them, as shown in Figure 9. Figure 9. Removing the RAID assembly from the system 3. Pull out the latches and remove the disk drive backplane from the system. Installing the IBM Power System E850 (8408-E8E)
  • Page 26: Attaching The Lift Handles To The Chassis

    This system requires three people to install the system into the rack. To install the system into the rack, complete the following steps: 1. Extend the mounting hardware (1) as shown in Figure 11 on page 11. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 27 6. Remove the lift handles on both sides of the chassis and store them for future use. 7. Release the latches in the middle of the rails and push the system all the way into the rack, as shown in Figure 12 on page 12. Installing the IBM Power System E850 (8408-E8E)
  • Page 28: Replacing Components Into The System Chassis

    1. Move to the front of the rack. 2. Slide the disk drive backplane into the system. 3. Push the latches in and tighten the thumbscrews, as shown in Figure 13 on page 13. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 29: Replacing The System Fans

    2. Using your hand to support the bottom of the fan, align the fan with the fan slot and slide it into the system. 3. Rotate the fan handle (A) in the direction shown and then press the fan handle until the latch locks in place. See Figure 14 on page 14. Installing the IBM Power System E850 (8408-E8E)
  • Page 30: Replacing The Front Cover

    1. Move to the front of the rack. 2. Position the cover (A) on the front of the system unit so that the four pins on the system match the four holes on the rear of the cover. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 31: Replacing The Power Supplies

    3. Align the power supply (A) with the bay and slide the power supply into the system until the terracotta latch (B) locks in place, as shown in Figure 16 on page 16. Installing the IBM Power System E850 (8408-E8E)
  • Page 32: Installing The Cable-Management Arm

    Figure 17 on page 17. Then use the T25 hex tool that was included with your system to tighten the bolts further. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 33 Figure 18. Figure 18. Attaching the nut clips to the rack rail Installing the IBM Power System E850 (8408-E8E)
  • Page 34: Cabling The Server And Setting Up A Console

    HMC” on page (HMC) Integrated AIX, or Linux Serial cable / “Cabling the server Virtualization Ethernet cable for and accessing the Manager for VIOS LAN connection IVM” on page 21 Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 35: Cabling The Server With An Ascii Terminal

    Table 2. Default settings for the diagnostic programs 3151 /11/31/41 3151 /51/61 3161 /64 General setup attributes settings settings settings Description Line speed 19,200 19,200 19,200 Uses the 19,200 (bits per second) line speed to communicate with the system unit. Installing the IBM Power System E850 (8408-E8E)
  • Page 36: Cabling The Server To The Hmc

    To cable the server to the HMC, complete the following steps: 1. If you want to directly attach your HMC to the managed system, connect Ethernet Connector 1 on the HMC to the HMC1 (T4) port on the managed system. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 37: Cabling The Server And Accessing The Ivm

    Notes: v You can also have multiple systems that are attached to a switch that is then connected to the HMC. For instructions, see HMC network connections (http://www.ibm.com/support/ knowledgecenter/POWER8/p8hai/netconhmc.htm). v If you are using a switch, ensure that the speed in the switch is set to Autodetection. If the server is directly attached to the HMC, ensure the Ethernet adapter speed on the HMC is set to Autodetection.
  • Page 38: Cabling The Server With Keyboard, Video, And Mouse

    2. Connect the monitor cable to the graphics card. 3. Connect a keyboard and mouse to the USB ports. 4. Power on the console. 5. Continue with “Cabling the server and connecting expansion units” on page 23. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 39: Cabling The Server And Connecting Expansion Units

    In the Tasks area, click Operations. c. Click Change password. The Update Password window opens. d. Type the required information and click OK. If you are using an HMC Enhanced+ interface, complete the following steps: Installing the IBM Power System E850 (8408-E8E)
  • Page 40 Type the required information and click OK. For more information about setting passwords for the managed system by using the HMC Classic or HMC Enhanced interface, see Setting passwords for the managed system (http://www.ibm.com/ support/knowledgecenter/POWER8/p8hai/setpasswordsforthemanagedsystem.htm). For more information about setting passwords for the managed system by using the HMC Enhanced interface, see Setting passwords for the managed system (http://www.ibm.com/support/knowledgecenter/...
  • Page 41: Completing The Server Setup Without Using An Hmc

    If you are using system plans or you did not log in to the HMC by using the HMC Enhanced or HMC Enhanced+ login option, you can create partitions or deploy system plans. v For instructions about creating partitions, see Partitioning with the HMC (http://www.ibm.com/ support/knowledgecenter/POWER8/p8hat/p8hat_lparwithhmcp6.htm).
  • Page 42: Setting Up A Preinstalled Server

    The power-on light on the control panel stops flashing and remains on, indicating that the system is powered on. For instructions, see Starting a system that is not managed by an HMC (http://www.ibm.com/ support/knowledgecenter/POWER8/p8haj/startsysnohmc.htm). 3. Install an operating system and update the operating system.
  • Page 43: Completing Inventory For Your Preinstalled Server

    You might need to read the following documents before you begin to install the server: v Installing the IBM Power System E850 (8408-E8E) (http://www.ibm.com/support/knowledgecenter/ POWER8/p8eha/p8eha_850_kickoff.htm). v To plan your server installation, see Planning for the system (http://www.ibm.com/support/ knowledgecenter/POWER8/p8had/p8had_8xx_kickoff.htm). v If you are using a Hardware Management Console (HMC), see Obtaining and applying machine code updates for the HMC with an Internet connection (http://www.ibm.com/support/knowledgecenter/...
  • Page 44: Removing The Shipping Bracket And Connecting Power Cords And Power Distribution Unit (Pdu) For Your Preinstalled Server

    5. If you ordered a fully-populated system, there are additional tasks you must perform so that you can access the line cord. To access the line cord on a fully-populated system, perform the following tasks: Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 45: Cabling The Server And Setting Up A Console

    AIX and Linux with a null modem with an ASCII terminal” on page 30 Hardware AIX, Linux, or VIOS Ethernet (or “Cabling the server Management Console cross-over cable) to the HMC” on page (HMC) Installing the IBM Power System E850 (8408-E8E)
  • Page 46: Cabling The Server With An Ascii Terminal

    5. Change the default password when you are prompted. 6. Press Enter until the server information appears. You have completed the setup for an ASCII terminal, and have started the ASMI. Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 47: Cabling The Server To The Hmc

    HMC version, release, Service Pack, build level, and base versions. If you need to update your HMC version and release, see Obtaining and applying machine code updates for the HMC with an Internet connection (http://www.ibm.com/support/knowledgecenter/POWER8/ p8hai/area3fixeshmc.htm). To cable the server to the HMC, complete the following steps: 1.
  • Page 48: Cabling The Server And Accessing The Ivm

    3) Select Boot to SMS menu in the AIX or Linux partition mode by boot field. ® 4) If you are installing the Integrated Virtualization Manager on an IBM System i model, select AIX or Linux in the Default partition environment field.
  • Page 49: Cabling The Server With Keyboard, Video, And Mouse

    Completing the server setup Learn about the tasks you must complete to set up your managed system. Select from the following options: v “Completing the server setup by using an HMC” on page 34 Installing the IBM Power System E850 (8408-E8E)
  • Page 50: Completing The Server Setup By Using An Hmc

    Type the required information and click OK. For more information about setting passwords for the managed system by using the HMC Classic or HMC Enhanced interface, see Setting passwords for the managed system (http://www.ibm.com/ support/knowledgecenter/POWER8/p8hai/setpasswordsforthemanagedsystem.htm). For more information about setting passwords for the managed system by using the HMC Enhanced interface, see Setting passwords for the managed system (http://www.ibm.com/support/knowledgecenter/...
  • Page 51 If you want to use an existing template from another source, you can import that and use it. For more information, see Importing a partition template (http://www.ibm.com/support/ knowledgecenter/POWER8/p8efc/p8efc_import_partition_template.htm). If you are using system plans or you did not log in to the HMC by using the HMC Enhanced or HMC Enhanced+ login option, you can create partitions or deploy system plans.
  • Page 52: Completing The Server Setup Without Using An Hmc

    The power-on light on the control panel stops flashing and remains on, indicating that the system is powered on. For instructions, see Starting a system that is not managed by an HMC (http://www.ibm.com/ support/knowledgecenter/POWER8/p8haj/startsysnohmc.htm). 4. Install an operating system and update the operating system.
  • Page 53 For instructions to get firmware fixes through the AIX or Linux operating system, see Getting server firmware fixes through AIX or Linux without a management console (http://www.ibm.com/ support/knowledgecenter/POWER8/p8ha5/fix_firm_no_hmc_aix.htm). v If you are using VIOS, see Updating the Virtual I/O Server's firmware and device microcode with an Internet connection (http://www.ibm.com/support/knowledgecenter/POWER8/p8ha5/...
  • Page 54 Power Systems: Installing the IBM Power System E850 (8408-E8E)
  • Page 55: Notices

    This information was developed for products and services that are offered in the USA. This material may be available from IBM in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it.
  • Page 56: Privacy Policy Considerations

    All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary.
  • Page 57: Trademarks

    IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 58 This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to European Standard EN 55022.
  • Page 59 Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures. IBM Taiwan Contact Information: Electromagnetic Interference (EMI) Statement - Korea Notices...
  • Page 60 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 61: Class B Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 62 This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards.
  • Page 63 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 64: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 65 Notices...
  • Page 66 IBM® Part Number: 00RW900 Printed in USA GI11-9913-01...

This manual is also suitable for:

8408-e8e

Table of Contents