Page 3
Item Unit Mono Bloc Unit Starting Current 13.0 Cooling: 13.0 Cooling: - Running Current Heating: 9.9 Heating: 10.8 Maximum Current For Mono Bloc Unit 22.9 Cooling: 96 Cooling: - Power Factor Heating: 95 Heating: 95 Power factor means total figure of compressor and outdoor fan motor. Number of core Power Cord Length...
Page 4
3. Features Inverter Technology - Energy saving High Efficiency Compact Design Environment Protection - Non-ozone depletion substances refrigerant (R410A) Easy to use remote control Weekly Timer setting Quality Improvement - Random auto restart after power failure for safety restart operation - Gas leakage protection - Prevent compressor reverse cycle - Inner protector to protect compressor...
4. Location of Controls and Components Mono Bloc Unit Air inlet (rear) Top Plate Air inlet (side) Cabinet Front Plate Air outlet Handle (2 pieces front and 2 pieces behind)
Page 6
4.1.1 Main Components (VIEW WITHOUT COVER) (VIEW WITHOUT PCB) DETAIL B DETAIL A View without cabinet top plate Component name Connector name Water inlet Cabinet top plate Pressure relief valve Overload protector Water outlet Flow switch Heater assembly Pressure gauge Expansion vessel Water pump Cover...
6. Refrigeration and Water Cycle Diagram Outdoor Side Mono bloc Unit Water Pressure Gauge Expansion Vessel Water Capillary Flow Expansion Liquid Side Tube Switch Valve Strainer Strainer (3-Way Valve) Water Inlet (Connect Receiver Water Pipe Pump Sanitary Temp. Tank) Sensor Pipe Temp.
Before adjust the water flow rate, make sure that the total water volume in the installation is 30 litres minimum for heating side. The default setting is SPEED 3 (Only for WH-MDC06G3E5) and SPEED 6 for WH-MDC09G3E5. Please ensure the minimum flow rate is not less than 9 l/min and not more than 35 l/min.
Page 12
18.1.2 WH-MDC09G3E5 Heating Characteristics at Different Outdoor Air Temperature Condition Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C 10.500 9.500 8.500 7.500 6.500 5.500 Outdoor Temperature (°C) 5.000 4.000 3.000 2.000 1.000 0.000 Outdoor Temperature (°C)
Page 13
Cooling Characteristics at Different Outdoor Air Temperature Condition Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C 8.500 7.500 6.500 5.500 4.500 3.500 Outdoor Temperature (°C) 3.500 3.000 2.500 2.000 1.500 1.000 Outdoor Temperature (°C)
Page 14
Cooling Characteristics at Different Outdoor Air Temperature Condition Indoor water inlet temperature : 19°C Indoor water outlet temperature : 14°C 11.000 10.000 9.000 8.000 7.000 6.000 Outdoor Temperature (°C) 3.500 3.000 2.500 2.000 1.500 1.000 Outdoor Temperature (°C)
Page 15
Cooling Characteristics at Different Outdoor Air Temperature Condition Indoor water inlet temperature : 23°C Indoor water outlet temperature : 18°C 11.500 10.500 9.500 8.500 7.500 6.500 Outdoor Temperature (°C) 3.500 3.000 2.500 2.000 1.500 1.000 Outdoor Temperature (°C)
9550 1730 9810 1680 5500 2030 6700 2060 7300 2050 4560 2340 6310 2470 7140 2450 18.3.2 WH-MDC09G3E5 Water In (°C) Water Out (°C) Capacity Input Power Capacity Input Power Capacity Input Power °C 5360 1050 6120 1080 7020 1080...