Installation Test (Duct Check)
Once you have completed the installation of the
dryer, use this test to make sure the condition of the
exhaust system is adequate for proper operation of
the dryer. This test should be performed to alert you
to any serious problems in the exhaust system of
your home.
• This dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces
energy use.
NOTE
The dryer should be cool before starting this test.
If the dryer was warmed up during installation, run
the AIR DRY cycle for a few minutes to reduce
the interior temperature.
To activate the installation test:
1
Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this test, as
in may affect the accuracy of the results.
2
Press and hold the POWER, Temp., and
Wrinkle Care buttons until
count alternate in the display. (The usage count
indicates the number of cycles run with no load
during the last 5 cycles.)
3
Press the START/PAUSE button.
The dryer will start the test, which will last about
2 minutes. The heat will be turned on and the
temperatures in the drum will be measured and
displayed. A chime sounds when the test portion
of the cycle is complete.
4
5
• Check the error code before you call for service
Error
Code
and a usage
or PF
or nP
gAS
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If the Flow Sense™
LED is not turned on, when the cycle ends,
the exhaust system is adequate. If the exhaust
system is severely restricted, the Flow Sense™
LED will be turned on. Other problems may also
be shown with error codes. See the chart below
for error code details and solutions.
LED; turned on :
RESTRICTED
The Flow Sense™ LED indicates that the exhaust
system is severely restricted. Have the system
checked immediately, as performance will be poor.
End of cycle.
At the end of the test cycle,
The test cycle will end and the dryer will shut off
automatically after a short delay.
Possible
Causes
tE1
• Temperature
or
sensor
tE2
failure.
• Humidity
HS
sensor failure.
• Electric
dryer power
cord is not
connected
correctly, or
house power
supply is
incorrect.
PS
• House fuse is
blown, circuit
breaker
has tripped,
or power
outage has
occurred.
• Gas supply or
service turned
off. (Gas
Model only.)
INSTALLATION
25
will display.
Solutions
• Turn off the dryer and
call for service.
• Turn off the dryer and
call for service.
• Check the power
supply or the
connection of the
power cord to the
terminal block. Refer
to the Connecting
Electric Dryers
section of this
manual for complete
instructions.
• Reset circuit breaker
or replace fuse. Do
not increase the
fuse capacity. If the
problem is a circuit
overload, have
it corrected by a
qualified electrician.
• Confirm that house
gas shutoff and the
dryer gas shutoff are
both fully open.