Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Industrial Ethernet network. You can find the system manual at the following link: (https://support.industry.siemens.com/cs/us/en/ps/25277) Trademarks The following and possibly other names not identified by the registered trademark sign ® registered trademarks of Siemens AG: SIMATIC RTLS SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Page 6
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions form one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
Page 7
Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity). Security recommendations General Note the following security recommendations to prevent unauthorized access: • Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://new.siemens.com/global/en/company/topic-areas/future-of-...
Device description Characteristics SIMATIC RTLS4460T Characteristics Design ① Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage, CAN bus and digital inputs and outputs General The transponder is the mobile device for locali- zation in the RTLS localization system. It sends position data to gateways which transmit the data to the Locating Manager server.
Digital input 3 Digital input 1 CAN high Digital output 1 24 V DC Connector Description not applicable Digital input 8 Digital input 6 Digital input 4 Digital input 2 CAN low Digital output 2 SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Page 11
Input 8 is different in that the impedance can be switched off. The input impedance is 110 kOhm in this case. ANT1 - Antenna - RP-SMA plug-in connector Use only the accessories specified in section "Order data RTLS4460T (Page 9)". SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Off when the transponder is not sending or receiving any data via the CAN bus Lights up for 1 second on system start Flashes yellow once per second if data was transferred via the CAN bus in the previous second SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Supply voltage When the supply voltage is connected, all LEDs light up for 1 second. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications (Page 17)". SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Technical specifications Table 4- 1 Technical specifications of the transponder RTLS4460T 6GT2700-6CE02 Product name SIMATIC RTLS4460T Wireless frequencies Wireless method IEEE 802.15.4a Chirp Spread Spectrum (CSS) Transmission speed 1 Mbit/s Frequency range 2400 ... 2480 MHz Transmit power Maximum 100 mW (configurable)
Page 18
4 mounting holes for M4 countersunk head screws and 1 oblong hole each on the front sides Plug-in connector (X1) 16-pin plug-in connector WR-MPC4 Würth-Elektronik, for single wires from 0.33 mm² to 1.31mm² Antenna connector RP-SMA Fuses Mini blade-type fuse, 2 A SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
You can check which of the following approvals have been granted for your product by the markings on the type plate. You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products?dtp=Certificate&mfn=ps&pnid=14970&lc=...
Page 20
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments • EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments SIMATIC RTLS4460T Operating Instructions, 05/2021, C79000-G8976-C522-04...
Page 21
ISM band and using wide band modulation techniques. Harmonized standard covering the essential requirements of article 3.2 of the EU Directive 2014/53/EU FCC information Siemens SIMATIC RTLS4460T (MLFB 6GT2700-6CE02); Contains FCC ID SIFNANOPAN5375V1 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 22
Approvals ISED information Siemens SIMATIC RTLS4460T (MLFB 6GT2700-6CE02); Contains IC ID 10971A_NANOPAN5375 This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.