Burner controls for the supervision of 1- or 2-stage gas or gas / oil burners of
small to medium capacity, operation, with or without fan in intermittent (26 pages)
Burner management system for forced draft burners with the main functions (39 pages)
Summary of Contents for Siemens LOGO! 8
Page 1
Application Example 07/2015 Street light control with LOGO! 8 and LOGO! CMR LOGO Set 1 https://support.industry.siemens.com/cs/ww/en/view/109063024...
If there are any deviations between the recommendations provided in this Application Example and other Siemens publications – e.g. Catalogs – the contents of the other documents shall have priority. We do not accept any liability for the information contained in this document.
Mode change via SMS ............... 8 Configuration and Settings ................9 Configuring LOGO! CMR for sending/receiving SMS messages ..9 Monitoring of signals/process values of LOGO! 8 with LOGO! CMR ....................13 Configuring time-of-day synchronization from LOGO! CMR via NTP server ..................15 Installation and Commissioning ..............
Time-of-day synchronization NTP server In the automation solution, the street light is controlled with a LOGO! 8 connected to a LOGO! CMR. Setting a manual street light control (user-defined mode) or an automatic control (astro clock mode) can be performed via SMS or LOGO! TDE.
Cost-efficient remote access for setting the switch-on time of the street lights via SMS. Hardware and software components 2.2.1 Validity This application is valid for LOGO! 8 LOGO! Soft Comfort V8 2.2.2 Components used The application was created with the following components: Hardware components...
3 Mode of Operation 3.1 Switching on the street lights by entering the time manually (user-defined mode) Software components Table 2-2 Component Article number Note LOGO!Soft Comfort 6ED1058-0BA08-0YA1 Version 8 Sample files and projects The following list includes all files and projects that are used in this example. Table 2-3 Component Note...
3 Mode of Operation 3.2 Function mechanism of the user-defined time of day input Note Please note that for the time of day value “00:00” h, the analog value “2400” must be entered. Entering the value “0000” as analog value prompts a warning message stating that the time format is wrong.
3 Mode of Operation 3.3 Automatic street light control (astro clock mode) Automatic street light control (astro clock mode) When setting the astro clock mode for controlling the street lights, street lighting is automatically switched off at sunrise and switched on at sunset. Changeover between astro clock mode/ user-defined mode: Changing between user-defined and astro clock mode is possible at any time via...
PC network, and that a SIM card has been inserted. Please ensure that the IP address of the network connection of your PC (or USB Ethernet adapter) used for connecting to LOGO! 8 is located in the same subnet as the LOGO! device and the LOGO! TDE. An instruction...
Page 10
4 Configuration and Settings 4.1 Configuring LOGO! CMR for sending/receiving SMS messages Action When initially logging on, you enter the Login “admin” and the Password “admin” (factory setting). Then you need to assign your own password. Navigate to “WAN > Mobile wireless settings” and make the following settings: Activate the “Activate mobile wireless interface”...
Page 11
4 Configuration and Settings 4.1 Configuring LOGO! CMR for sending/receiving SMS messages Action Navigate to “User/groups > User” and make the following settings: Enter a name (in this case, not the user login) and a description for the user who is to gain access to operating the application.
Page 12
4 Configuration and Settings 4.1 Configuring LOGO! CMR for sending/receiving SMS messages Action Navigate to “User/groups > Recipient groups”) and make the following settings: Click on “Add”. Enter a name and a description of your user group. Select which of the users you entered shall be added to the recipient group, by activating the respective checkbox next to the user name.
LOGO! CMR, as described in Chapter 4.1, you can, in the web interface (WBM) of LOGO! CMR, specify which signals and process values of LOGO! 8 shall be able to be monitored via SMS or changed at any time. Table 4-2 Action In the web interface (WBM) of LOGO! CMR you navigate to “Monitoring”...
Page 14
4.2 Monitoring of signals/process values of LOGO! 8 with LOGO! CMR Action In “Message texts” you can enter possible SMS message texts. All signals of LOGO! 8 to be changed or monitored via SMS, need to be entered at “Signal definitions”. Note: Please ensure that analog values from LOGO! 8, to be monitored or changed with LOGO! CMR must previously be entered in LOGO! Soft Comfort V8 at “Tools >...
To complete the configuration for monitoring the signals or process values of LOGO! 8 with the LOGO! CMR, all possible “Events” defined for the signals of LOGO! 8 need to be linked with the “Action” to be performed in “Assignments”.
Page 16
Select the “NTP” procedure as “Time-of-day synchronization method”. Enter the address of the NTP server (DNS name or IP address) Activate the “Forward time of day to LOGO! BM” checkbox so the time of day of LOGO! 8 is synchronized.
Page 17
4 Configuration and Settings 4.3 Configuring time-of-day synchronization from LOGO! CMR via NTP server Action Navigate to “WAN > mobile wireless settings” and activate the “Activate data connection via the mobile wireless network” checkbox. Enter the access details of your mobile network operator if you are able to use the mobile data services (internet) of the mobile network operator.
Commissioning 5.3.1 Assigning IP addresses and subnet masks to devices For LOGO! 8 and LOGO! TDE, one IP address and one subnet mask each must be assigned so they are located in the same subnet. LOGO! Set 1 Entry ID: 109063024, V1.0,...
5 Installation and Commissioning 5.3 Commissioning LOGO! 8 Information on how to assign an IP address and a subnet for LOGO! 8 is available in the LOGO! manual in Chapter “Configuring network settings”. LOGO! TDE Information on how to assign an IP address for the LOGO! TDE is available in the LOGO! manual in Chapter “LOGO! TDE settings menu”.
Page 20
5 Installation and Commissioning 5.3 Commissioning Table 5-2 Action In the web interface (WBM) you navigate from LOGO! CMR to “Maintenance > Configuration”. Click “Browse” and select the storage location of the downloaded configuration file. If you have saved the downloaded configuration file on a micro SD card, you can also download the configuration directly via the micro SD card.
Page 21
5 Installation and Commissioning 5.3 Commissioning Action Now go to “WAN > Mobile wireless settings” and make the following settings: Enter the PIN of the SIM card inserted in the LOGO! CMR. If necessary, enter the phone number of the SMS service center of your provider. To be able to use the time-of-day synchronization via NTP server, the data connection via mobile radio network must be activated.
5.3.3 Downloading a program into LOGO! 8 Note It is assumed that LOGO! 8 has been connected to a power supply and a PC network. In this application example a completed LOGO! program for LOGO! 8 is offered for download. The table below contains a description on how to load the completed LOGO! program into LOGO! 8.
“SMSwrite;LOGO=VM6,2200,WORD”. Note: The command for writing a value to LOGO! 8 follows a defined structure <Password>;LOGO=VM<address>,value>,<data_type>. In the SMS command at the top, the following values were entered according to this structure: password “SMSwrite”...
LOGO! TDE Table 6-2 Action On LOGO! 8 or LOGO! TDE you press the ESC button for at least one second The parameter for changing the time of day is marked black (at present, time of day “15:24” is still set).
6 Operating the Application 6.3 Changing between user-defined mode/astro clock mode via SMS Action Use the keys to move the curser to the parameter you wish to change. Use the curser keys to change the parameter. Note: When editing the parameters for the time via LOGO! or LOGO! TDE, please note that you need to leave a blank for the first digit.
Product No.: LOGO! MTS Internet link specifications Table 7-2 Topic Link Siemens Industry https://support.industry.siemens.com Online Support Download page of the https://support.industry.siemens.com/cs/ww/en/view/109063024 entry LOGO! 8 Manual https://support.industry.siemens.com/cs/ww/en/view/100761780/67518106635 LOGO! CMR Manual https://support.industry.siemens.com/cs/ww/en/view/103657268/78256255755 FW Update 1.1 for https://support.industry.siemens.com/cs/ww/en/view/109475356 LOGO! CMR2020 History Table 8-1 Version Date Modifications V1.0...