1.
SAFETY INSTRUCTIONS
" Familiarise yourself with the application and limitations of the air hose reel, as well as the specific hazards.
! WARNING! Disconnect the air hose reel from the air supply before changing accessories, servicing or performing any maintenance.
" Maintain the air hose reel in good condition (use an authorised service agent).
" Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
" Locate and fix the air hose reel in a suitable working area. Do not position the hose in direct sunlight, or in areas of extreme heat or
cold. Ensure there is adequate lighting.
! WARNING! Ensure maximum air pressure is not exceeded.
" Keep extended air hose away from heat, oil and sharp edges. Check hose for wear before each use, and ensure all connections are secure.
" Keep the unwound air hose at a safe distance from the working area and free from wet, damp, oily surfaces.
! WARNING! Always wear approved eye or face protection when operating the air hose reel.
" Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
" Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery and contain and/or tie back long hair.
" Keep children and unauthorised persons away from the working area.
# DO NOT operate the air hose reel if any parts are damaged or missing as this may cause failure and/or personal injury.
# DO NOT exceed the rated capacity of the air hose reel.
# DO NOT use the air hose reel for any purpose other than that for which it is designed.
# DO NOT operate the air hose reel when you are tired or under the influence of alcohol, drugs or intoxicating medication.
# DO NOT direct air from the air hose at yourself or others.
" When not in use ensure the air supply is turned off and tools disconnected. Disconnect from the air supply and retract the hose into case.
! WARNING! DO NOT dismantle the hose reel casing, or attempt to remove the screws and covers on the sides. To do so may result in
damage to the appliance and/or personal injury and will invalidate the warranty. Internal maintenance, which will require the opening of the
casing, must only be undertaken by an authorised service agent.
2.
INTRODUCTION & SPECIFICATIONS
Tough, impact resistant, durable, composite case with wall/ceiling
mounting bracket. SA88.V4 fitted with 20mtr high quality TPR hose
with 1/4"BSP outlet. Solid brass full flow 3/8"BSP inlet swivel
connector. SA8812 fitted with 15mtr high quality TPR hose with
½
"BSP outlet. Solid brass full flow
3.
INSTALLATION
! WARNING! Ensure the hose is disconnected from the air supply. Do not position the reel in areas of extreme heat or cold.
NOTE: Prolonged exposure to direct and intense sunlight may affect the integrity of the polymers within the moulded components.
Avoid, if possible, positioning the reel in direct sunlight.
3.1
MOUNTING THE REEL
3.1.1
Due to the way the retractable hose operates, the reel should only be mounted in one of two positions shown below. The brackets
supplied will enable you to mount the reel in either position.
3.1.2
Ensure the wall, ceiling or other structure, to which the air hose reel is to be fixed, is of sound construction and that the securing
points will hold the working strain of the hose when in use.
3.1.3
Using the mounting holes template (cut from box lid), drill appropriate holes for the desired mounting or see diagram below.
3.1.4
When wall mounted the hose exit point should not be more than 2.4 mtrs above floor level. Above this height ceiling mounting is
recommended. See diagrams below.
3.1.5
Screw fix one bracket to the chosen surface using fixings that are appropriate to the substrate and strong enough to carry the weight
of the reel plus the working strain exerted on it when in use. Position the hose reel onto the first bracket, then proceed to fix the
second bracket into place and ensure the reel is secure.
3.1.6
Connect the air supply to the reel using a flexible hose sufficiently long to allow the reel to swivel 180° from side to side.
1. WALL MOUNTING
½
" BSP inlet swivel connector.
INSTRUCTIONS FOR:
RETRACTING AIR HOSE REEL
SA88.V4 &
MODEL NO:
Hose Length:
- - - - - - - - - - -20mtr
- - - - - - - - - - -
Hose Size (ID):
- - - - - - - - - -10mm
- - - - - - - - - -
Max. Pressure:
- - - - - - - - - -250psi
- - - - - - - - - -
Hose Type:
- - - - - - - - - - - - -TPR
- - - - - - - - - - - - -
Inlet - Outlet:
- - - - - -3/8" - 1/4"BSP
- - - - - -
2. CEILING MOUNTING
SA8812
SA88.V4
SA8812
- - - - - - - - - - - -15mtr
- - - - - - - - - - - -
- - - - - - - - - - - -13mm
- - - - - - - - - - - -
- - - - - - - - - - -250psi
- - - - - - - - - - -
- - - - - - - - - - - - -TPR
- - - - - - - - - - - - -
½
- - - - - - - -
" -
- - - - - - - -
SA88.V4 & SA8812 - 1 - 100106
½
"BSP

Advertisement

loading

Summary of Contents for Sealey POWER PRODUCTS SA88.V4

  • Page 1 SA8812 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 98/37/EC Machinery Directive 93/68/EEC CE Marking Directive For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

This manual is also suitable for:

Power products sa8812