Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
WARNING! Ensure Health & Safety, local authority, general
workshop practice regulations are adhered to when using
this equipment.
WARNING! Installation site must be equipped with
suitable fire extinguishers (water must not be used) and
escape routes.
WARNING! Disconnect the air supply from the tank before
changing accessories, servicing or performing any
maintenance.
Maintain the tank in good condition (use an authorised service
agent).
Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the
warranty.
locate the tank in a suitable work area. ensure the tank
stands on a firm, level surface. Keep area clean and tidy and
free from unrelated materials. ensure the area is well
ventilated and has adequate lighting.
WARNING! Ensure specified air pressure is maintained
and not exceeded.
Keep air hose away from heat, oil and sharp edges. Check air
hose for wear before each use, and ensure that all
connections are secure.
WARNING! This tank is recommended for use only with
degreasing solvents suitable for air operated tanks.
Ensure you follow makers instructions for solvent use.
ensure solvent flash point is above 140°F. We recommend
you use Sealey solvent - contact your local dealer for details.
Keep the tank clean. Remove and clean the suction filter
regularly for best performance.
WARNING! DO NOT SMOKE and keep sources of ignition,
such as heaters, lamps, etc., away from the unit, together
with flammable or combustible materials, as there is an
explosion risk.
DO NOT modify or jam the parts washer lid open, as this will
make the fusible fire link inoperative which is dangerous
practice and will invalidate the warranty and your insurance.
When cleaning parts ensure that nothing in the tank,
including any parts basket, is in a position that would
prevent the lid from closing fully if and when the fusible
link activates.
WARNING! Wear approved safety eye protection, mask
and gloves. If solvent gets on skin or in eyes wash
thoroughly with water and take any other action as
required by the solvent instructions.
Remove ill fitting clothing, ties, watches, rings and other loose
jewellery, contain long hair and wear appropriate protective
clothing.
Maintain correct balance and footing. ensure the floor is not
slippery and wear non-slip shoes.
Keep non-essential persons away from the working area.
In case of fire in tank, do not attempt to move unit or remove
parts from tank. The lid is fusible and will automatically close
extinguishing fire.
Avoid accidental starting of the washer by ensuring the unit is
disconnected from the air supply when not in use.
DO NOT use the tank for any purpose other than for which it is
designed.
DO NOT operate the tank if any parts are missing or damaged
as this may cause failure and/or personal injury.
DO NOT over-fill the tank.
DO NOT use air line to blow dry components in tank. Only use
air gun supplied. dO NOT direct air gun at yourself or others.
DO NOT leave the parts washer operating unattended.
INSTRUCTIONS FOR:
AIR OPERATED PARTS CLEANING TANK
MOdel Nos:
and properly maintained, give you years of trouble free performance.
Original Language Version
SM221 & SM223
When cleaning is complete, ensure all controls are in the 'off'
position and that the air supply is disconnected.
WARNING! It is operator's responsibility to ensure that
there is no uncontrolled discharge of any fluids used with
this unit and that appropriate arrangements have been
made for correct disposal of waste in accordance with
government/local authority regulations.
2. INTRODUCTION & SPECIFICATION
The heavy duty steel tank is made in one piece and is fitted with a
fully sealed, air operated, magnetic drive pump unit. The tank is
suitable for cleaning large engine components. Included is an air
blow gun for fast drying of workpiece. The lid of tank is fitted with
fusible link hinge which automatically snaps lid shut in the event of a
fire. Supplied with removable shelf and parts basket.
SPECIFICATION Model SM221
Minimum working capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45ltr
Maximum working capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70ltr
Pump output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300l/h
Operating pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-125psi
Air consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tank width x length x height. . . . . . . . . . . . . . . . . 510 x 890 x 265mm
Overall height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890mm
Air inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BSP
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35kg
SPECIFICATION Model SM223
Minimum working capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55ltr
Maximum working capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85ltr
Pump output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300l/h
Operating pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-125psi
Air consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10cfm
Tank width x length x height. . . . . . . . . . . . . . . . 510 x 1070 x 265mm
Overall height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890mm
Air inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BSP
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42kg
3. ASSEMBLY
As you unpack the product, check contents. Should there be
any damaged or missing parts contact your supplier immediately.
3.1.
Remove all parts from the carton and from inside the tank.
3.2
IMPORTANT! You must remove the transit bolt from the
lid stay as indicated in fig.1 as the fire safety mechanism
will not work if the bolt remains in place.
3.3.
lay clean cardboard on the floor to protect the tank paint
work and carefully turn the tank upside down whilst holding
the lid closed.
3.4.
Assemble legs to the brackets on the bottom of the tank with
screws and hex nuts, (hand tight only).
3.5.
Set the lower shelf among the four legs and fix with screws
and hex nuts.
level the
shelf and
tighten
screws.
3.6.
Now tighten
the leg screws
and carefully
turn assembled
unit up correct
way onto it's
legs whilst
holding the lid
closed.
8-10cfm
fig.1
SM221, SM223
Issue: 5 - 05/11/09

Advertisement

loading

Summary of Contents for Sealey POWER PRODUCTS SM221

  • Page 1 SM221 & SM223 MOdel Nos: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 5.2. Fill the tank to appropriate capacity (See specifications) with (fig 3.6) regularly for best and safest performance. Sealey solvent, or a general purpose degreaser (contact your 7.2. Regularly check and top up the oil in the air supply oiler.
  • Page 3 INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. ������� ������������������ ������������ ������������ ������������� �������������������������� Sole UK Distributor, Sealey Group, www.sealey.co.uk 01284 757500 Kempson Way, Suffolk Business Park, ������������������������� Bury St. edmunds, Suffolk, 01284 703534 sales@sealey.co.uk...

This manual is also suitable for:

Power products sm223