HYDROSTATIC DRIVE SYSTEM
Hydrostatic Drive Transmission (Cont.)
Installation (Right side shown) (Cont.)
14. Add hydraulic oil to the proper level using the vent plugs (Figure 21).
Vent Plug
Figure 21
see "Purging Procedure," chapter 7, page
15. Follow the purging procedure to remove all air from the system,
7-8.
16. Adjust the neutral setting if necessary,
see "Hydrostatic Drive Belt Installation," chapter 7, page 7-11.
17. Lower the unit and verify proper function.
18. Adjust the tracking if necessary,
see "Tracking Adjustment," chapter 7, page 7-6.
19. Connect the battery terminals and verify proper function.