E Maintenance
www.honeywellsafety.com
E1.
A fall arrester which has arrested a person's fall from a height must
not be used again until a competent person has agreed on its further
use. If no competent person is available, the fall arrester must be
returned to the manufacturer or authorized dealer for inspection
together with these instructions.
E2.
Depending on use requirements and operational conditions, the fall
arrester must be inspected by a competent person for unimpaired
condition to ensure it is in perfect working condition as required, but at
least once a year. For reasons of safety the fall arrester may only be
repaired by the manufacturer.
Competent person is a:
person who due to his training and experience in the field of personal
protective equipment against falls from height has sufficient
knowledge about applicable state and local safety regulations,
applicable standards (e.g. EN-standards) and is thus capable and thus
authorized by Söll of judging the correct status and use of systems
and products against falls from height.
Warning!
E3.
The gap between the slider (2) and the shuttle casing must not be
more than 6 mm. If this value is exceeded, the fall arrester must be sent
back to the manufacturer for revision.
Fig. E1
page 17 of 24