hit counter script

Technical Data And Characteristics; Explanations; Explanations Of The Formula Abbreviations - Siemens SIMOTICS T-1FW6 Series Configuration Manual

High speed built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Technical data and characteristics

The technical data and characteristics for the 1FW6 High Speed built-in torque motors are
stated in this chapter. This data collection provides the motor data required for configuration
and contains a number of additional data for more detailed calculations for detailed analyses
and problem analyses. Technical data subject to change.
Note
System-specific data refer to the combination of 1FW6 High Speed built-in torque motors
with SINAMICS S120 drive systems.
Unless otherwise specified, the following boundary conditions apply here:
• The DC link voltage U
• The motor is water-cooled with the recommended minimum volume flow rate according to
the data sheet and a water flow temperature T
• The rated temperature of the motor winding T
• Voltages and currents are specified as rms values.
• Installation altitude of the motors up to 2000 m above sea level.
• For motors with integrated cooling that are equipped with main and precision coolers, the
power/performance data has been determined with the use of a cooling connection
adapter.
6.1

Explanations

6.1.1

Explanations of the formula abbreviations

Content of the data sheet
The data specified on the data sheets is explained in the following section. It is categorized
as follows:
● Boundary conditions
● Data at the rated operating point
● Limit data
● Physical constants
● Data for the motor cooler
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
is 600 V, the converter output voltage U
DC
a max
of 20 °C
VORL
is 130 °C
N
6
is 425 V
139

Advertisement

Table of Contents
loading