Basic dismantle/assembly

The steps described below are the basic steps that must be carried out before any other service or repair
work or final assembly is possible.

6.1 Battery

Press in the catches and remove the battery. See
figure 1.
Put the battery back once assembly has been
completed.
WARNING!
The battery must always be removed
for service/repair work and may only
be put back once the pole saw has
been fully assembled again!
NOTE!
Note how wires, components, etc., are posi-
tioned before dismantling.
Make sure to position them correctly to avoid
pinching when the pole saw is reassembled.

6.2 Trigger guard

Remove the screws and push the guard forward.
See figure 2.

6.3 Battery housing skidplate

Undo the screws and remove the skidplate from
the battery housing.
Assemble in the reverse order.
See figure 3.