This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50%
*
Particulate Class l
85%
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg /L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Asbestos
99.0%**
‡
Cysts
99.95%
Turbidity
0.5 NTU
Endrin
0.002
O-Dichlorobenzene
0.60
Toxaphene
0.003
Ethyl Benzene
0.70
1,2,4- trichlorobenzene 0.07
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NLC120V: Change the water filter cartridge every
6-9 months. Use replacement cartridge NLC120V, part
#4396701. 2004 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
†
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
††
Fibers greater than 10 um in length
‡
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
Base Grille Water Filtration System
Model WF-NLC120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene, Cysts, Turbidity, Asbestos, Endrin,
O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene
and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste
and Odor and Particulate Class I.
Average
Influent Challenge
Influent
Concentration
1.9 mg/L
2.0 mg/L ± 10%
5,300,000/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
†
0.14 mg/L
0.15 mg/L ± 10%
†
0.15 mg /L
0.15 mg /L ± 10%
0.0058 mg/L
0.006 mg/L ± 10%
0.0055 mg/L
0.006 mg /L ± 10%
0.0153 mg/L
0.015 mg/L ± 10%
0.215 mg/L
0.225 mg/L ± 10%
842 x 10
7
10
7
to 10
165,500/mL
50,000/L min.
11.75 NTU
11 ± 1 NTU
0.0056
0.006 ± 10%
1.84
1.8 ± 10%
0.0143
0.015 ± 10%
2.00
2.1 ± 10%
0.232
0.21 ± 10%
Maximum
Effluent
0.12 mg/L
50,000/mL**
Maximum
Effluent
0.001 mg/L
0.001 mg/L
0.0005 mg/L
0.0013 mg /L
0.0036 mg/L
0.0037 mg/L
††
8
fibers/L
1.6 x 10
7
mg/L 1.6 x 10
1 mg/L
0.38 NTU
0.0007
0.33
0.001
0.60
0.0025
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
0.08 mg/L
>75%
15,725/mL
99.0%
Average
Minimum %
Effluent
Reduction
0.001 mg/L
99.29%
0.001 mg/L
99.32%
0.0003 mg/L
91.37%
0.0005 mg/L
76.36%
0.0014 mg/L
76.47%
0.0010 mg/L
98.27%
7
mg/L
99.81
1 mg/L
99.99%
0.22 NTU
96.76%
0.0004
87.50
0.071
82.06
0.001
93.00
0.169
70.00
0.0007
98.92
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.89 L/min.) @ 60 psi.
Average %
Reduction
>75%
99.7%
Average %
Reduction
99.29%
99.32%
94.82%
90.90%
90.84%
99.52%
99.81%
99.99%
98.12%
92.85
96.14
93.00
91.55
99.69
19