Summary of Contents for Siemens SINUMERIK 840D sl Series
Page 1
Overview of System Error Alarms Overview of Alarms SINUMERIK 840D sl/840D/840Di/810D List of Action Numbers Error Codes of Alarm 300500 System Reactions on Alarms Diagnostics Guide Appendix Valid for Control SINUMERIK 840D pl/840D sl SINUMERIK 840DE pl/840D sl (export version) SINUMERIK 840Di SINUMERIK 840DiE (export version) SINUMERIK 810D powerline...
Page 2
08.05 6FC5298-7AA20-0BP2 Trademarks SIMATIC®, SIMATIC HMI®, SIMATIC NET®, SIROTEC®, SINUMERIK® and SIMODRIVE® are Siemens trademarks. Other product names used in this documentation may be trademarks which, if used by third parties, could infringe the rights of their owners. More information is available on the Internet at: Other functions not described in this documentation may be execut- http://www.siemens.com/motioncontrol...
• General documentation • User documentation • Manufacturer/service documentation Please contact your local Siemens office for more detailed information about other SINUMERIK 840D sl/840D/840Di/810D publications and publications that apply to all SINUMERIK controls (e.g. universal interface, measuring cycles, etc.). An overview of publications, which is updated monthly and also provides informa- tion about the language versions available, can be found on the Internet at: http://www.siemens.com/motioncontrol...
- Interface signals are set. - Alarm display. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Page 14
Reactions: - Alarm display. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Clear alarm with the Delete key or NC START.
Page 15
- Interface signals are set. - Alarm display. - NC Stop on alarm. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Switch control OFF - ON. tinuation:...
Page 16
- Interface signals are set. - Alarm display. - NC Stop on alarm. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Clear alarm with the RESET key. Restart part program...
Page 17
- Interface signals are set. - Alarm display. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Page 18
- NC Stop on alarm. - Alarm reaction delay is canceled. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Page 19
No memory card or memory card without valid firmware (license) inserted. Reactions: - Alarm display. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000) Program Con- Switch control OFF - ON.
Page 62
The alarm is only a notice. There is no interference with any NCK functions. It shows that the NCK has less free user memory available than specified by Siemens for this control variant. The value of the actually available free user memory can also be taken from the machine data $MN_INFO_FREE_MEM_DYNAMIC, $MN_INFO_FREE_MEM_STATIC.
Page 80
- Alarm display. Remedy: Apart from reducing the number of CC alarms, no remedial measures are possible at the present time. (contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm 1000) Program Con- Clear alarm with the Delete key or NC START.
Page 81
%1 = (string) name of the specific .elf file %2 = (int) required option bit (hex) Definitions: Alarm for SIEMENS compile cycles. This alarm appears when the option bit required for a SIEMENS compile cycle is not set. Reactions: - NC not ready.
Page 82
- Alarm display. Remedy: Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UAC- CESS_ DEF. Please see the Siemens Programming Guide or the OEM documentation for the language commands permissible for the relevant system configurations. Program Con- Clear alarm with the RESET key. Restart part program...
Page 86
- Alarm display. Remedy: Please inform the authorized personnel/service department. For retrofitting the option, please refer to your machine manufacturer or to a sales representative of SIEMENS AG, A&D MC. Program Con- Clear alarm with the Delete key or NC START.
Page 174
Definitions: The programmed language element is not allowed or unknown in external language mode. Only the language elements from Siemens mode which are used for subprogram calls (except for Lxx) and the language constructs for program repetition with REPEAT (UNTIL) are allowed.
Page 180
- Interface signals are set. - Alarm display. Remedy: Modify parts program. Please see the Siemens Progamming Guide or OEM documenta- tion for the language commands permissible for the relevant system configuration. Program Con- Clear alarm with NC START or RESET key and continue the program.
Page 225
OEM application) error-free execution is possible on repeating the program or operator action. Otherwise, the A&D MC system support should be contacted with a precise description of the error situation: (contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:see alarm 1000) Program Con- Switch control OFF - ON.
Page 367
Typical reasons of display are present, if the operator works with the function 'definite D numbers', which can be displayed on Siemens MMC in a definite form only, if exactly one tool from a tool group has the status 'active'.
Page 465
08/2005 Overview of Alarms - Interface signals are set. - Alarm display. Remedy: Please contact the responsible Siemens regional office. Program Con- Clear alarm with the RESET key. Restart part program tinuation: 61239 Channel %1 Block %2: Tool change point lies within retraction area!
Page 537
- NC Start disable in this channel. - Interface signals are set. - Alarm display. Remedy: If this error occurs, please contact us on the SINUMERIK Hotline of the SIEMENS AG, specifying the error number. Program Con- Clear alarm with the RESET key. Restart part program...
Page 589
Velocity/Speed is negative Definitions: The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindel start/stop. Reactions: - Alarm display. Remedy: Inform the sevice department. Please contact the responsible Siemens regional office. Program Con- Internal tinuation: 111111 Setpoint speed is zero Definitions: The programmed spindle speed setpoint is zero.
Page 590
Definitions: The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindel start/stop. Reactions: - Alarm display. Remedy: Inform the sevice department. Please contact the responsible Siemens regional office. Program Con- Internal tinuation: 111127 Absolute value plus not possible Definitions: The alarms 111110, 111115, 111126, 111127 and 111200 can occur at spindel start/stop.
Page 595
While the contour pocket was being calculated, an error occurred. The contour pocket cannot be calculated. The program cannot be started. Reactions: - Alarm display. Remedy: Make a note of the error text and contact the Siemens AG, A&D MC hotline. Program Con- Internal tinuation: 112100 Error on renumbering.%nInitial state restored.
Page 601
Definitions: A system error has occurred. Reactions: - Alarm display. Remedy: Please contact the hotline of Siemens AG, A&D MC and provide with the error message. Program Con- Clear alarm with the Delete key or NC START. tinuation: 112504 File does not exist or is faulty%n%1...
Page 602
Definitions: A system error has occurred. Reactions: - Alarm display. Remedy: Please contact the hotline of Siemens AG, A&D MC and provide with the error message. Program Con- Clear alarm with the Delete key or NC START. tinuation: 112604 Connection to PLC aborted...
Page 617
The files are stored in sub-directory "SEditor" of the "TMP" directory in HMI Advanced. Remedy: Follow the instructions in log file "ITSx.LOG" or contact the Siemens hotline. 142000 Operator at the machine is waiting for support via remote diagnostics! %1 %2 %3...
Page 621
Remedy: - check the selected component number (p7828). - check the DRIVE-CLiQ connection. - save suitable firmware file for download in the directory /siemens/sinamics/code/sac/. - after POWER ON has been carried-out again for the DRIVE-CLiQ component, download the firmware again.
Page 622
<location>CF card corrupt Reaction: NONE Acknowledge: NONE Cause: At least one file in the directory /SIEMENS/SINAMICS has been illegally changed with respect to the state when originally supplied. Alarm values: 0: MD5 checksum incorrect 1: File missing 2: Too many files...
Page 623
The value for xxx depends on p0977 with which the save operation was started: p0977 = 1, 10, 11, 12 --> xxx = 0, 10, 11, 12 The two most significant bytes are used for internal Siemens troubleshooting. Remedy: Check whether one of the files to be overwritten has the attribute "read only" and change this file attribute into "writable".
Page 701
Acknowledge: IMMEDIATELY Cause: No rated data are stored in the power module EEPROM. See also: r0206, r0207, r0208, r0209 Remedy: Replace the power module or inform Siemens Customer Service. 207815 <location>Drive: Power module has been changed Reaction: NONE Acknowledge: IMMEDIATELY Cause: The code number of the actual power module does not match the saved number.
Page 711
6: The current measurement must be re-calibrated. 7x: The sensor module does not support the pole position identification routine. 70 ... 79: Only for internal Siemens troubleshooting. 8: The pole position identification routine current required is greater than the maximum current.
Page 824
• Other hardware faults. If the remedial measures given above do not lead to a change in the behaviour when starting, please contact the system support for the A&D MC products of SIEMENS AG through the Hotline (tel.: see alarm 1000).
Page 825
Please inform the authorized personnel/service department. If the alarm has occurred in conjunction with a power failure, this cause of failure must be eliminated. Otherwise, please contact the system support for A&D MC products, SIEMENS AG, through the Hot- line (tel.: see alarm 1000).
Page 826
The search for the precise cause of error can only be performed by the development team. The displayed status code is always needed for this. (contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm 1000).
Page 827
- Interface signals are set. - Alarm display. - NC Stop on alarm. Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000). Program Con- Switch control OFF - ON. tinuation:...
Page 828
The search for the precise cause of error can only be performed by the development team. The displayed error codes are always needed for this. (contact SIEMENS AG, Sys- tem Support for A&D MC products, Hotline (Tel.: see alarm 1000).
Page 829
Please inform the authorized personnel/service department. The alarm can be sup- pressed with ENABLE_ALARM_MASK bit 1 == 0 SIEMENS AG, System Support for A&D MC products, Hotline (Phone: see alarm 1000) Program Con- Clear alarm with the Delete key or NC START.
Page 831
Any further search for the precise cause of error can only be performed by the develop- ment team. The displayed error codes are always needed for this. Reinitialization of the drive required. Please inform the authorized personnel/service department. System Support, SIEMENS A&D MC, Hotline (Tel.: see alarm 1000). Program Con- Switch control OFF - ON.
Page 833
• Check the shield connection of the front plate of the closed-loop control module (top screw). • Use original, preassembled encoder cable from Siemens (high degree of shielding). • If necessary, replace the motor, encoder and/or cables. • With linear motor, check the signal level; possibly, the measuring scale of the open mea- suring system is polluted.
Page 836
- Channel not ready. Remedy: • Use original Siemens encoder cables (they have a higher degree of screening). • Check the encoder, encoder cables and screen connection for damage. • Check the shield connection on the front plate of the controller module (top screw).
Page 860
• Modify MD 1400: $MD_MOTOR_RATED_SPEED (rated motor speed) • Modify MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weak- ening) • Modify MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current). • Call the SIEMENS AG, SIMODRIVE Hotline. Program Con- Switch control OFF - ON. tinuation:...
Page 861
• Modify MD 1144: $MD_LH_CURVE_GAIN (Lh curve gain) • Modify MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weak- ening) should be checked and, if necessary corrected. • Call the SIEMENS AG, SIMODRIVE Hotline. Program Con- Switch control OFF - ON.
Page 869
Overview of Alarms Remedy: The current set in MD1019: $MD_CURRENT_ROTORPOS_IDENT (rotor position identi- fication current) that is not smaller the permissible minimum value (40% for non-Siemens synchronous linear motor (SLM)). Possibly, a larger power section must be used. If allowed with the motor used, hide the error by setting bit 5 in MD 1012: $MD_FUNCTION_SWITCH (function switch).
Page 878
- Channel not ready. Remedy: Please inform the authorized personnel/service department. Change the filter setting. The Hotline provides support for accurate troubleshooting. Call the SIEMENS AG, SIMO- DRIVE Hotline. Program Con- Clear alarm with the RESET key in all channels. Restart part program.
Page 883
• For standard motors: Execute a general drive reset (delete the boot file) and repeat the startup. • For non-Siemens motors: Check and, if necessary, refer to the motor data sheet to cor- rect machine data MD 1103: $MD_MOTOR_NOMINAL_CURRENT (nominal motor cur- rent) and MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
Page 885
For standard motors: Execute a general drive reset (delete the boot file) and repeat the startup. For non-Siemens motors: Check and, if necessary, correct the following machine data with reference to the data sheet: • Modify MD 1132: $MD_MOTOR_NOMINAL_VOLTAGE (nominal motor voltage) •...
Page 999
Suggestions Siemens AG Corrections For Publication: A&D MC BMS Postfach 3180 SINUMERIK 840D sl/840D/840Di/810D 91050 ERLANGEN, GERMANY Diagnostics Guide Phone ++49-(0)180-5050-222 [Hotline] Fax ++49-(0)9131-98-63315 [Documentation] User Documentation Email: motioncontrol.docu@siemens.com User Manual From Order No.: 6FC5298-7AA20-0BP2 Name: 08/2005 Edition Company/Dept.: Should you come across any printing errors...