4.
5.
6.
----End
4.4.2.4 Using the V8 Switch Module CLI to Collect Ethernet Switching Plane
Information
Operation Scenario
Use the CLI of an E9000 switch module to collect the following information about
the V8 platform:
●
●
●
For details about how to query the Ethernet switching plane version, see
Querying the Software Version of the Ethernet Switching
Issue 20 (2020-09-25)
<Fabric>ftp 200.1.1.126
Trying 200.1.1.126 ...
Press CTRL+K to abort
Connected to 200.1.1.126.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(200.1.1.126 none):root
331 Give me your password, please
Enter password:
230 Logged in successfull
[ftp]
NO TE
The IP address of the FTP server is configured by the user and is on the same network
segment as the management IP address of the switch module.
Convert the log file into a binary file for transfer.
[ftp]binary
Obtain the log file.
[ftp]put flash:/diag-info.txt
200 PORT command okay
150 "F:\diag-info.txt" file ready to receive in IMAGE / Binary mode
226 Transfer finished successfully.
FTP: 148848 byte(s) sent in 0.280 second(s) 531.60Kbyte(s)/sec.
[ftp]lcd flashVX:/logfile
The current local directory is flashVX:/logfile.
[ftp]mput *
Error: The file name . is invalid.
Error: The file name .. is invalid.
200 PORT command okay
150 "F:\log.dblg" file ready to receive in IMAGE / Binary mode
226 Transfer finished successfully.
FTP: 1513938 byte(s) sent in 1.160 second(s) 1305.11Kbyte(s)/sec.
200 PORT command okay
150 "F:\log.log" file ready to receive in IMAGE / Binary mode
226 Transfer finished successfully.
FTP: 2689148 byte(s) sent in 1.940 second(s) 1386.15Kbyte(s)/sec.
[ftp]quit
View the log file in the FTP directory on the PC.
Logs
Debugging information
Trap information
Copyright © Huawei Technologies Co., Ltd.
4 Collecting Information
4.4.1.2
Plane.
23