Huawei Servers
Troubleshooting
Example: Administrator@SMM:/#ipmcset -l swi2 -d ipaddr -v 172.200.2.153
255.255.0.0 172.200.0.1
----End
4.4.1.2 Querying the Software Version of the Ethernet Switching Plane
Query the software version of the switching plane before upgrading a switch
module.
Prerequisites
●
●
●
●
Procedure
Step 1 Connect the PC to the Ethernet switching plane.
For details, see
Step 2 Log in to the CLI of the Ethernet switching plane by using the SOL function of the
MM910.
For details about SOL login, see
Passthrough Module, or Switch Module by Using the SOL Function of the
MM910.
Step 3 Run the following command to query the version of the Ethernet switching plane:
display version
●
Issue 20 (2020-09-25)
The switch modules have been powered on.
For logging in to the Ethernet switching plane over SSH, the default username
is root and the default password is Huawei12#$.
By default, the MM910 username is root and the password is Huawei12#$.
You are familiar with the parameters required for this operation.
Table 4-3 Parameter description
Parameter
IP address and subnet mask of the
management network port on the
Ethernet switching plane
Floating IP address, subnet mask,
and gateway of the MM910
4.4.1.1 Connecting a PC to the Ethernet Switching
Information similar to the following is displayed:
BoardName
: CX910
CPLD Version
: 003
PCB Version
: VER.A
Bootrom Version
: 008
Creation Time
: Sep 17 2012, 09:53:25
Backup Bootrom Version : 008
Copyright © Huawei Technologies Co., Ltd.
Example Value
● IP address of the management
network port: 192.168.9.61
● Subnet mask: 255.255.255.0
● IP address: 10.85.4.77
● Subnet mask: 255.255.255.0
● Gateway: 10.85.4.1
8.17 Logging In to a Compute Node,
4 Collecting Information
Plane.
17