Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instruction
Wear Protective
Gloves
Manual
1. SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when building this shed.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the working area.
DO NOT use the shed for any purpose other than that for which it is designed.
Use appropriate safety clothing including eye protection.
Note! The assembly of this product will require assistance.
2. INTRODUCTION
Galvanized steel panels easily assembled to form rigid and secure structure with pent (sloping) roof. Doors are secured by cross bolt and
eyelet which will accept a padlock (not included) for additional security. Supplied with bolt down fixing kits.
3. SPECIFICATION
Model no: . . . . . . . . . . . . . . . . . . . . . . . GSS1515.V2 . . . . . . . . . . . . . . . . . . . . . . . . . . . GSS1515G.V2
Colour: . . . . . . . . . . . . . . . . . . . . . . . . . . Silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Green
Roof: . . . . . . . . . . . . . . . . . . . . . . . . . . . Pent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pent
Doors: . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overall Size (W x D x H*) . . . . . . . . . . . 1510 x 1510 x 1900mm . . . . . . . . . . . 1510 x 1510 x 1900mm
*Minimum Wall Height:
© Jack Sealey Limited
INSTRUCTIONS FOR:
GALVANIZED STEEL SHED 1510 x 1510 x 1900mm
GSS1515.V2, GSS1515G.V2
:
MODEL No's
Wear Eye
Wear Safety
Protection
Footwear
Original Language Version
GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17

Advertisement

loading

Summary of Contents for Sealey GSS1515.V2

  • Page 1 Model no: ..... . . GSS1515.V2 ....
  • Page 2 This will allow for a 50mm edge around your shed. We recommend that you slope the 50mm edges downward by 10mm so that rain water can drain away from your shed. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 3 Side wall Sheet 1900-1980x770 Sheet Sheet1600x770 Roof Sheet Sheet 1900x708 Front Door Sheet Sheet 1845x770 Door Channel Channel 1843 Door Channel Channel 1843 Door Channel Channel 768 Door Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 4 Channel Channel 674 Front Jamb Jamb 1898 Front � Jamb Jamb 1898 Front � � Jamb Jamb 775 Front � Brace Corner brace 1898 Corner Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 5 5/16 x 19mm Hexagonal bolt 5/16 Hexagonal Nut Mid wall brace bracket ® Channel safety cover Self tapper safety cover �� (L type) ® Channel safety cover Plastic stopper (R type) Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 6 In the unlikely event that you find you are missing a part, please contact Pinnacle at 1800 349 776. A copy of proof of purchase may be requested. Shed overview: Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 7 Make sure the small lip of the channel is always facing out. This ensures rainwater cannot build up inside your shed. ROOF TOP EDGE RIDGES FACING UP Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 8 Position the top and bottom channels with self-tapping screws as well. NOTE: All screws marked with a cross should not be fixed at this stage. RIDGES FACING DOWN Tip: If panel and screw holes do not line up, try pulling panel to match up holes. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 9 fixed at this stage. RIDGES FACING UP ROOF TOP EDGE ROOF TOP EDGE RIDGES FACING UP Note: Channel 31 should face down. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 10 Now tap or slide in 2 x part 20A (channels) onto the sheeting and fix them to the top and bottom with the self-tapping screws provided. Make sure that the small lips on channels 20A are always facing out. This ensures rainwater cannot build up inside your shed. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 11 Step 4: Assemble the roof panel (continued) Now fit 2 x part 51 (side lips) to the sheeting and fix them with the self-tapping screws provided. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 12 Fit part 41A (jamb), part 42 (jamb) and part 23 (bottom channel) and fix them with the self tapping screws (except those marked with a cross). Make sure both joins (diagrams A and B) are fixed the same followed by diagrams C and D. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 13 FIXW ITH3 .0*10MMR IVET FIX WITH 3.0MM RIVETS RIDGES FACING UP FIXW ITH3 .0*10MMR IVET FIX WITH 3.0MM RIVETS FIXW ITH3 .0*10MMR IVET FIX WITH 3.0MM RIVETS Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 14 Once channels are fitted to both doors, align 2 x part U12 (brace) and part W (joining brace) with holes on the back of the door and position temporarily with some tape or simply hold in place. BACK Turn door over so the ridges are facing down. Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 15 FIXW ITH3 .0*10MMR IVET through the front panel with ridges facing up. RIDGES FACING DOWN WHITE PLASTIC STOPPER WHITEP LASTIC STOPPER WHITE PLASTIC WHITEP LASTIC STOPPER STOPPER Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 16 FIX DOOR HINGES WITH 4.0 X 10MM RIVETS FIX PAD BOLT WITH 3.0 X 10MM RIVETS Original Language Version Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 1 - 07/12/16 GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited © Jack Sealey Limited...
  • Page 17 FIX PAD BOLT KEEPER FIXP ADBOLT KEEPER WITH 16MM SCREWS WITH 16mm SCREWS FIX PAD BOLT KEEPER FIXP ADBOLT KEEPER WITH 3.0 X 10MM RIVETS WITH 3.0*10MM RIVET Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 18 WALL SHEET BOLT & NUT BOLT & NUT WALL SHEET STEEL ANGLE STEELA NGLE SLAB SLEEVE ANCHOR BOLT SLEEVEA NCHORB OLT DOOR DOOR Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 19 Original Language Version Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 1 - 07/12/16 GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited...
  • Page 20 fill them with rivets. Perform the same procedure for the pad bolt. Original Language Version Original Language Version GSS1515.V2, GSS1515G.V2 Issue: 1 - 07/12/16 GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17 © Jack Sealey Limited © Jack Sealey Limited...
  • Page 21: Environmental Protection

    Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal of it according to local regulation NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without prior notice.