Thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear a mask
instruction
manual
1. SAFETY
1.1.
ELECTRiCAL SAFETY
WARninG! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
DO nOT pull or carry the appliance by the power cable.
8
DO nOT pull the plug from the socket by the cable.
8
DO nOT use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or is replaced
8
immediately by a qualified electrician.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GEnERAL SAFETY
WARninG! Compressor must only be serviced by an authorised agent.
Familiarise yourself with the application and limitations of the compressor.
9
ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and
9
contact an electrician / service agent.
Before moving, or maintaining the compressor, ensure it is unplugged from the mains supply and that the air brush is disconnected.
9
DO nOT attach anything other than an air brush to the compressor.
8
ensure the safe working pressure of any air brush used, exceeds the units output pressure.
9
ensure the area selected for spraying is provided with suitable ventilation.
9
ensure the compressor is turned off before disconnecting the air brush.
9
To move the compressor use the handle only.
9
ensure it is placed on a firm surface.
9
Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.
9
ensure the air brush supply hose is not tangled, twisted, or pinched.
9
Keep children and unauthorised persons away from the working area.
9
DO nOT disassemble compressor for any reason. The unit must be checked and serviced by an approved service agent.
8
DO nOT use the compressor outdoors, or in damp, or wet locations.
8
DO nOT operate within the vicinity of flammable liquids, gases or solids.
8
DO nOT touch compressor cylinder head as it may be hot and will remain so for some time after shutdown.
8
DO nOT attempt to move the compressor by pulling the air brush supply hose. only move the compressor by its handle.
8
DO nOT use this product to perform a task for which it has not been designed.
8
DAnGER! DO nOT direct the output jet of air towards people or animals.
When not in use, store the compressor carefully in a safe, dry, childproof location.
9
© Jack Sealey limited
mini AiR BRUSH COmPRESSOR
model no:
Wear eye
Warning!
Indoor use only
protection
Hot surface
Original Language Version
AB900.V4
Recommended fuse rating
13 Amp
AB900.V4 | Issue:1
23/09/19

Advertisement

loading

Summary of Contents for Sealey AB900.V4

  • Page 1 AB900.V4 model no: Thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Quiet running piston pump, powered by a 122W motor - suitable for most air brushes. Requires no lubrication and the air supply from the unit is oil free. Supplied with an air filter regulator and pressure gauge. 3. SPECiFiCATiOn model no: ............... AB900.V4 Power: ................122W Supply: ................230V Free air delivery: ............
  • Page 3 Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...