Dimensional drawings:
Installation:
1
4
Mounting methods
ImperLED E luminaries can be surface mounted on walls or ceilings. For these mounted installations, special
accessories are included. A recessed kit is also available.
Step 1: Place a flat blade screwdriver and pull up gently the 6 diffusor clips from both sides to remove the
diffusor.
Step 2: Place a flat blade screwdriver and pull up gently the reflector.
Step 3: Install the plastic base with the included mounting screws and plugs. If the hole that exists is not useful,
drill another hole on one of the designated positions in order to pass the cables and install the included
gasket (verify that it is not deformed).
Step 4: Always use in any case round cable, with a diameter of 5-10mm (H05RN-F type 2x1mm
type, at least equal to its mechanical and electrical properties). ATTENTION! The cable must not be
deformed in any way (this requirement is important to ensure the IP rating).
Make a hole in the center by using a small screwdriver. Pass the round cable through the gasket.
Step 5: Connect the mains cable to the respective terminal block: L for live wire, N for neutral. Power supply
cables cross section should be 0.8 – 3 mm
(optional), DALI communication (optional) or voltage-free contact (optional).
Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
ImperLED E
2
5
. The C1 and C2 terminals are used for elBus communication
2
3
or any other
2
http://www.hls-nordic.com
GB