Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETy
WARNING! ensure Health & Safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
WARNING! disconnect the extractor from the air supply before changing accessories, servicing or performing any maintenance.
WARNING! ensure that you wear protective clothing, gloves, goggles, face mask as appropriate for the fluid being extracted.
Keep the extractor clean and maintain it in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Check extractor connections and fittings before use. When the extractor is turned on check that there are no leaks.
9
ensure that the extractor's tank capacity exceeds the amount of fluid to be collected.
9
Avoid unintentional starting of the extractor and ensure that the end of the suction tube is fully submerged in the fluid before operating.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
dispose of waste fluids in accordance with local authority regulations.
9
Use only to extract engine or transmission oils, or similar non-corrosive fluids. Unit may also be used for the transfer of water.
9
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.
DO NOT pull or yank any pipes or hoses and DO NOT attempt to move the extractor by pulling the hose.
8
DO NOT leave the extractor operating unattended.
8
DO NOT use to extract hazardous or harmful chemicals, solvents, petrol, diesel, kerosene, alkaline or acids. If by chance such fluids
8
are used in the unit, it must be immediately drained and thoroughly cleaned. Use with prohibited fluids will invalidate your warranty.
DO NOT store fluids in the extractor's tank. After extracting fluid, it must be emptied into an approved receptacle as soon as possible.
8
DO NOT dismantle, tamper or adapt the extractor for any purpose other than for which it is designed.
8
DO NOT store in areas of high temperature, direct sunlight, rain or snow.
8
DO NOT leave the unit in a pressurised state.
8
WARNING! When the extractor's tank contains liquid that is under pressure DO NOT remove or insert the extension tube connector into
the inlet/outlet fitting as this may result in a sudden discharge of liquid that could be dangerous.
Always press the pressure relief button before connecting or disconnecting the extension tube.
9
dO NOT direct the air line at yourself or others.
2. INTRODUCTION
9l Capacity device constructed from composite materials. Uses manual pump or compressed air supply to generate vacuum.
Suitable for the extraction of all types of engine, transmission and lubricating oil from cars, motorcycles, marine engines, stationary
engines and industrial machinery. Also suitable for low viscosity fluids such as water. Supplied with Ø4, Ø6, Ø8 x 1000mm suction
probes, Ø10 x 1000mm extension tube and 1200mm brake bleed tube. Uses probes to extract engine oil through the dipstick tube.
3. SpECIFICATION
Model: ........................................................................ S01168
Capacity: ........................................................................... 9 l
Suction probes: Ø 4x1000, Ø6x1000, Ø8x1000mm, 1200mm Brake bleed tube
extension hose: .............................................Ø10 x 1000mm
Supply: ................................................................ 90psi(5cfm)
4. AIR SUppLy
When using a workshop air supply, the recommended hook-up is shown below.
4.1.
ensure that the air valve (see fig.3) is in the "off" position before connecting to the air supply.
4.1.1.
You will require an air pressure and an air flow (cfm) according to the specification.
WARNING! ensure the air supply is clean and does not exceed the pressure quoted.
WARNING! Too high an air pressure and/or unclean air will shorten the life of the extractor due to excessive wear and may be
dangerous, causing damage and/or personal injury.
© Jack Sealey limited
9L MANUAL/AIR VACUUM OIL & FLUID
EXTRACTOR
Model no:
Wear protective
gloves
Original Language Version
S01168
S01168 Issue 1 25/10/19

Advertisement

loading

Summary of Contents for Sealey Siegen Tools S01168

  • Page 1 S01168 Model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Connect the extracting probe to the extension tube using its black plastic adaptor. The tubes are a push fit into the adaptor. 5.2.5. Position the extractor unit close to the front or side of the vehicle. Press fit the 10mm diameter suction tube adaptor to the inlet coupling (fig.3). WARNING! Ensure oil temperature does not exceed 70°C. ‰ Original Language Version S01168 Issue 1 25/10/19 © Jack Sealey limited...
  • Page 3 Apply copper grease to the brake bleed nipples before and after the brake bleeding procedure to eliminate the possibility of seized or broken nipples when the brakes are next bled (See fig.7). fig.5 fig.6 fig.7 7. MAINTENANCE 7.1. Keep the unit clean, wipe off any fluid spillage. Keep the suction tubes clean and clear of blockages. Check that all tubes, hoses and connections are in good condition. Original Language Version S01168 Issue 1 25/10/19 © Jack Sealey limited...
  • Page 4 Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, kempson Way, Suffolk business park, bury St Edmunds, Suffolk. Ip32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk...