hit counter script
Download Print this page

Siemens SIMODRIVE 6SN11 Series Planning Manual page 71

Ac motors for feed and main spindle drives

Advertisement

09.00
2.2
Termination technology
AC motor connec-
The type of terminal box used, the number of terminals, cross–sections which
tion
can be connected, number of auxiliary terminals and cross–section for the PE
connection are specified in the following tables.
Table 2-2
Overview of the termination technology for 1PH4 motors
Motor
No. of
Max. cross–section
main ter-
minals
Shaft
3xM5
height100
Shaft
3xM5
35 mm
height 132
Shaft
3xM10
70 mm
height160
Table 2-3
Overview, termination technology for 1PH7
Motor
No. of
Max. cross–section
main ter-
minals
Shaft
6xM5
height 100
Shaft
6xM6
35 mm
height 132
Shaft
6xM6
50 mm
height 160
Shaft
3xM12
2 x 50 mm
height 180
Shaft
3xM12
2 x 50 mm
height 225
Caution
!
Please observe the motor current for your particular application! Please dimen-
sion the connecting cables adequately in compliance with IEC 60204-1.
1)
Cable cross–section corresponds to the supply feeder cable cross–section
 Siemens AG 2000 All rights reserved
SIMODRIVE Planning Guide Motors (PJM) – 11.00 Edition
Terminal strip for
the temperature
sensor
2
16 mm
3 terminals
2
with cable lug
3 terminals
connection
2
with cable lug
3 terminals
connection
Terminal strip for
the temperature
sensor
2
25 mm
3 terminals
2
with cable lug
3 terminals
connection
2
with cable lug
3 terminals
connection
2
with cable
4 terminals
lug connection
2
with cable
4 terminals
lug connection
6SN1197–0AA20
General Information on AC Induction Motors
2.2 Termination technology
PE connection size/cable lug width
M4/9 mm
M5/15 mm
M6/15 mm
PE connection size/cable lug width
M5/9 mm
M6/15 mm
M6/15 mm
Without cable lug, using a terminal clamp
Without cable lug, using a terminal clamp
ALA
1)
1)
ALA/2-17