Page 2
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Introduction The IS220 is a dual optic bench scanning engine with scan lines optimized for orthogonal orientation of 1D bar codes. IS220 is a completely self-contained scan engine. Base Kit Part Number Description IS220-16 IS220 OEM Engine ( RS232 ) 00-02029 IS220 Installation and User’s Guide *...
Case Dimensions Figure 1. Case Dimensions Specifications subject to change without notice. Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the horizontal or vertical output windows require cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non-abrasive cleaning cloth then gently wipe the window clean.
Indicators Audible Indicators When the IS220 is in operation, it provides audible feedback. These sounds indicate the status of the scan engine. One Beep The scan engine will beep once when it first receives power, the red LED will flash and the scanner will beep once.
Visual Indicators Steady Green When the laser is active the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated. During the power save mode, the laser will turn on and turn off. During this period, the green LED will remain illuminated. Steady Green and a Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once.
Diagnostic Indicator Display There is a two-digit error code display located on the center printed circuit board (see illustration below). The following is a list of possible error codes and their meanings. Some errors will require immediate scanner maintenance. Error Description Code Reserved...
Page 12
MOTOR #1 (left) ERROR – The motor in the left scanning subsystem denotes a failure. The scanner will try three times to correct the motor operation. If the motor error persists, the left scanning subsystem will be shut down and error code 31 will remain on the diagnostic indicator display.
No power is being No LEDs, Some host systems cannot supply enough current to power an supplied to the IS220. Use the power supply included with the scanner. No beep. scanner from host. The unit beeps There has been a...
Page 16
POSSIBLE SYMPTOMS SOLUTION CAUSE(S) The unit is scanning a particular UPC/EAN is enabled by default. symbology that is not Verify that the type of bar code being read has been enabled. enabled. The scanner has The unit powers been configured for a up, but does not Verify that the bar code being scanned falls into the configured character length lock,...
Page 17
POSSIBLE SYMPTOMS SOLUTION CAUSE(S) The bar code may have been printed Check if it is a check digit/character/or border problem. incorrectly. The unit beeps for The scanner is not some bar codes configured correctly and NOT for Check if the check digits are set properly. for the type of bar others of the same code.
Upgrading the Flash ROM Firmware The IS220 is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires, a new firmware file supplied to the customer by a customer service representative and MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade.
Default Settings Communication Parameters Many functions of the scanner can be "configured" - that is, enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages.
Page 24
Parameter Default RS232 GS1 DataBar ID “]e0” GS1 DataBar App ID “01” GS1 DataBar Check Digit GS1 DataBar Expanded Enable Expanded ID “]e0” GS1 DataBar Limited Enable GS1 DataBar Limited ID “]e0” GS1 DataBar Limited App ID “01”...
Page 25
Parameter Default RS232 Convert EAN-8 to EAN-13 EAN-13 Enable Transmit EAN-13 Check Digit UPC-A Enable Convert UPC-A to EAN-13 Transmit UPC-A Check Digit Transmit UPC-A Number System Transmit UPC-A Manufacturers ID. Transmit UPC-A Item ID ...
Page 26
Parameter Default RS232 Message RTS Character RTS ACK / NAK O / N Handshaking Host Bell / Cancel Xon / Xoff No Transmit Without DTR Present French PC Terminal Emulation “D/E” Disable Command ...
Page 27
Parameter Default RS232 Programmable Prefix for Code Types Programmable Suffix for Code Types Programmable Code Lengths 7 avail Code Selects 7 avail Code Select Timeout 0.1 to 25.5 seconds 5 sec Replace 1 Character in Transmission ...
Scanner and Cable Terminations Scanner Pinout Connections Standard 15-pin, Male D-Sub Function Shield GND External LED Earth Ground External Beeper Cable Connector Configurations 52-52548 and 52-52547 Communication/Power Cable Standard 15-pin, Female D- Standard 9-pin, Female D-Sub Function Function Shield GND...
These warranties are non-transferable. The duration of the limited warranty for the IS220 is two (2) year(s). The accessories have a 90 day limited warranty from the date of manufacture.
Laser and Product Safety Cautions Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device.
Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
Page 38
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
Page 40
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02029 Rev C 5/11...