hit counter script
Siemens SIMATIC HMI Series Operating Instructions Manual

Siemens SIMATIC HMI Series Operating Instructions Manual

Industrial flat panels v2
Hide thumbs Also See for SIMATIC HMI Series:
Table of Contents

Advertisement

IFP V2, IFP V2 PRO
SIMATIC HMI
Industrial Flat Panels V2
IFP V2, IFP V2 PRO
Operating Instructions
08/2019
A5E46641410-AA
Preface
Overview
Safety information
Installing and connecting the
device
Commissioning the IFP
Operating the IFP
Maintaining and servicing
your device
Technical information
Technical Support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC HMI Series

  • Page 1 IFP V2, IFP V2 PRO Preface Overview SIMATIC HMI Safety information Installing and connecting the device Industrial Flat Panels V2 IFP V2, IFP V2 PRO Commissioning the IFP Operating the IFP Operating Instructions Maintaining and servicing your device Technical information Technical Support Markings and symbols List of abbreviations...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface These operating instructions contain all the information you need for commissioning and using the Industrial Flat Panel SIMATIC IFP V2 and the Transceiver Unit. These operating instructions are intended both for programming and testing personnel who commission the devices and connect them to other units (automation systems, programming devices), and for service and maintenance technicians who carry out maintenance work or fault analyses.
  • Page 4 Preface Conventions The following conventions apply in these operating instructions: ● The term "device" is used for all SIMATIC IFP V2 devices, SIMATIC IFP V2 PRO devices and the Transceiver Unit. ● The term "IFP" is also used for all SIMATIC IFP V2 devices and SIMATIC IFP V2 PRO devices.
  • Page 5: Table Of Contents

    Table of contents Preface ............................3 Overview ............................9 Product description ......................9 Scope of delivery of the IFPs ..................... 11 Structure of the built-in devices ..................12 Design of the PRO devices ....................14 1.4.1 PRO devices for support arm (not extendable, flange top) ..........14 1.4.2 PRO devices for pedestal (extendable, flange bottom) ............
  • Page 6 Table of contents Mounting the PRO device ....................49 3.3.1 Notes on mounting ......................49 3.3.2 PRO devices for support arm (not extendable, flange top) and for pedestal (extendable, flange bottom) ....................51 3.3.3 PRO devices for support arm (extendable, round tube) ............53 Installing Transceiver Unit ....................56 Connecting the device ......................58 3.5.1...
  • Page 7 Table of contents Information on insulation tests, protection class and degree of protection ......93 Dimension drawings ......................95 7.6.1 Dimension drawing of the IFP1500 V2 and IFP1500 V2 extended ........95 7.6.2 Dimension drawing of the IFP1900 V2 and IFP1900 V2 extended ........96 7.6.3 Dimension drawing of the IFP2200 V2 and IFP2200 V2 extended ........
  • Page 8 Table of contents IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 9: Overview

    Overview Product description SIMATIC IFPs are industrial LCD monitors with a brilliant TFT display that can be connected to SIMATIC IPCs and to almost all commercially available PCs. Features of the built-in units ● Rugged front in different design versions ●...
  • Page 10 Overview 1.1 Product description Features of the PRO devices The PRO devices are connected to a 24 V DC power supply and have the following features in addition to the extended versions: ● All-round dust-proof and splash-proof with degree of protection IP65 and Enclosure Type 4X/12 (indoor use only) ●...
  • Page 11: Scope Of Delivery Of The Ifps

    Overview 1.2 Scope of delivery of the IFPs Scope of delivery of the IFPs The product package includes the following components: Name Figure Number Installation instructions (Quick Install Guide) Accessory kit "Mounting clips power supply connector" Strain relief plate Including 3 screws T10, M3x8 Base adapter Including 4 screws T20,...
  • Page 12: Structure Of The Built-In Devices

    Overview 1.3 Structure of the built-in devices Structure of the built-in devices This section describes the structure of the built-in devices using the example of the IFP1900 V2 extended. Front view and side view ① Display and capacitive multi-touch screen ②...
  • Page 13 Overview 1.3 Structure of the built-in devices Rear view ① Position of rating plate ② Threaded holes for fastening the strain relief plate IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 14: Design Of The Pro Devices

    Overview 1.4 Design of the PRO devices Design of the PRO devices 1.4.1 PRO devices for support arm (not extendable, flange top) This section describes the structure of the PRO devices for support arm (not extendable, flange top) using the example of the IFP1900 PRO for support arm (not extendable, flange top).
  • Page 15: Pro Devices For Pedestal (Extendable, Flange Bottom)

    Overview 1.4 Design of the PRO devices Rear view ① Mechanical interface for fastening ② Rating plate ③ Enclosure ④ Backplane cover 1.4.2 PRO devices for pedestal (extendable, flange bottom) This section describes the structure of the PRO devices for pedestal (extendable, flange bottom) using the example of the IFP1900 PRO for pedestal (extendable, flange bottom).
  • Page 16 Overview 1.4 Design of the PRO devices Bottom view ① Mechanical interface for fastening Rear view ① Backplane cover ② Enclosure ③ Rating plate ④ Mechanical interface for fastening IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 17: Pro Devices For Support Arm (Extendable, Round Tube)

    Overview 1.4 Design of the PRO devices 1.4.3 PRO devices for support arm (extendable, round tube) This section describes the structure of the PRO devices for support arm (extendable, round tube) using the example of the IFP1500 PRO for support arm (extendable, round tube). Front view and side view ①...
  • Page 18: Interfaces

    Overview 1.5 Interfaces Interfaces Standard versions ① ④ Connection for functional ground X71 DVI-D interface ② ⑤ X80 connector for 24 V DC power supply X61/X62 USB Type A ③ ⑥ X70 DisplayPort interface X60 USB Type B Extended versions and PRO devices ①...
  • Page 19: System Components For Ifps

    Overview 1.6 System components and accessories 1.6.1 System components for IFPs Transceiver Unit for extended versions and PRO devices With the Transceiver Unit you can bridge a distance of up to 100 m between a PC and an extended version or a PRO device. The Transceiver Unit is mounted close to the PC. The Transceiver Unit can be attached on a DIN rail or in various positions on a wall using the fixing accessories supplied.
  • Page 20 Article number of the AC power supply unit: 6AV7860-3PA00-0AA0 You can find the documentation for the AC power supply unit with the article number on the Internet (https://support.industry.siemens.com). WARNING Do not use the power supply unit in hazardous areas.
  • Page 21: System Components For Pro Devices

    ● Adapter set VESA100 for VESA100-compatible systems, Article number 6AV7674-0KD00-0AA0 In addition, other manufacturers offer support arm or pedestal systems with mechanical interfaces or adapters for Siemens PRO devices, e.g. RITTAL, ROLEC, BERNSTEIN, HASEKE, ROSE. Observe the specifications provided by the respective manufacturer. IFP V2, IFP V2 PRO...
  • Page 22 Overview 1.6 System components and accessories Flange mount adapter A flange mount adapter is available for mounting a PRO device for support arm (extendable, round tube). ① Flange mount adapter ② Ring groove for fastening on PRO device with setscrews ③...
  • Page 23 Overview 1.6 System components and accessories Extensions for PRO devices: The following example shows a PRO device for a support arm (extendable, round tube) with Extension Unit, Extension Unit box as well as the PRO Options handles and keyboard tray with keyboard tray plate.
  • Page 24 In addition, different operator controls, such as emergency stop button, selector switch, illuminated button, keyswitch and indicator light are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. Extension Unit box The Extension Unit box offers a deep empty housing to install larger customer-specific components underneath a 16:9 SIMATIC PRO device for pedestal (extendable, flange bottom) or for support arm (extendable, round tube).
  • Page 25: Accessories

    Industry Mall on the Internet (https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10144445). Details such as the delivery quantity and technical specifications of accessories can be found in the Industry Mall under the respective article numbers.
  • Page 26 Overview 1.6 System components and accessories Accessories for extended versions and PRO devices Name Specification Article number Cat. 6A Ethernet cable 10 m long 6AV7860-0EH01-0AA0 15 m long 6AV7860-0EH01-5AA0 20 m long 6AV7860-0EH02-0AA0 30 m long 6AV7860-0EH03-0AA0 Cable set, consisting of 10 m long 6AV7860-1EX21-0AB1 15 m long...
  • Page 27: Safety Information

    Safety information General safety instructions The device is designed for use in the industrial sector for operating and monitoring plant processes. Machinery Directive WARNING The device may only be used in machines which comply with the Machinery Directive The Machinery Directive specifies precautions to be taken when commissioning and operating machinery within the European Economic Area.
  • Page 28 Safety information 2.1 General safety instructions Additional notes for built-in units WARNING The built-in device is an open equipment at the rear The built-in device is an open equipment at the rear. This means that you have to integrate the built-in device into an enclosure or a cabinet, where the built-in device is operated via the front panel.
  • Page 29 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to...
  • Page 30: Notes About Usage

    Safety information 2.2 Notes about usage Notes about usage NOTICE Device approved for indoor use only The device may be damaged if operated outdoors. Operate the device indoors only ("Indoor use only"). Note Operate the device only in a normal atmospheric environment The technical characteristics of the device described in the operating instructions are guaranteed if you operate the device in normal ambient air conditions with usual air composition.
  • Page 31 Safety information 2.2 Notes about usage Use in residential areas Note Device not intended for use in residential area The device is not suitable for use in residential areas. Operation of the device in residential areas can affect radio or TV reception. Use with additional measures The device should not be used at the following locations unless additional measures are taken:...
  • Page 32 • The device may not be used in harsh operating environments, such as areas subject to acidic vapors or gases, without additional protective measures (e.g. a clean air supply). • Only use suitable detergents. For IFPs, read the information about chemical resistance on the Internet (https://support.industry.siemens.com/cs/ww/en/view/39718396). TFT displays NOTICE Burn-in effect A permanently displayed two-color or multi-color picture can cause a burn-in effect, i.e.
  • Page 33: Use In Hazardous Areas

    Safety information 2.3 Use in hazardous areas Defective pixels in the display The manufacturing process of modern displays does not currently guarantee that all pixels of the display are perfect. It is therefore inevitable that the display will contain a small number of defective pixels.
  • Page 34 Safety information 2.3 Use in hazardous areas IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 35: Installing And Connecting The Device

    Installing and connecting the device Preparing for installation 3.1.1 Checking the delivery package Procedure 1. When accepting a delivery, please check the packaging for visible transport damage. 2. If any transport damage is present at the time of delivery, lodge a complaint at the shipping company in charge.
  • Page 36 Installing and connecting the device 3.1 Preparing for installation 6. Please inform the delivery service immediately if the package contents are incomplete or damaged or do not correspond with your order. Fax the enclosed form "SIMATIC IPC/PG Quality Control Report". WARNING Electric shock and fire hazard due to damaged device A damaged device can be under hazardous voltage and trigger a fire in the machine or...
  • Page 37: Built-In Devices

    Installing and connecting the device 3.1 Preparing for installation 3.1.2 Built-in devices 3.1.2.1 Permitted mounting positions The built-in device is intended for installation in: ● Mounting cabinets ● Control cabinets ● Switchboards ● Consoles In the following, all of these mounting options are referred to by the general term "cabinet". The built-in device is self-ventilated and approved for inclined mounting at angles up to +/-35°...
  • Page 38 Installing and connecting the device 3.1 Preparing for installation Mounting in landscape format Mounting in portrait format Note Portrait format must also be supported by the software Only install the built-in device in portrait format if the software used supports portrait format. IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 39: Required Clearance

    Installing and connecting the device 3.1 Preparing for installation 3.1.2.2 Required clearance The following clearance is required for sufficient self-ventilation around the built-in device: ● At least 15 mm to the right and left of the mounting cutout (in x direction) to allow for insertion of the mounting clips during installation ●...
  • Page 40: Preparing The Mounting Cutout

    Installing and connecting the device 3.1 Preparing for installation 3.1.2.3 Preparing the mounting cutout Note Stability of the mounting cutout The material in the area of the mounting cutout must be sturdy enough to ensure permanent safe mounting of the device. To achieve the degrees of protection described below, it must be ensured that deformation of the material cannot occur due to the force of the mounting clips or operation of the device.
  • Page 41: Installing A Strain Relief

    Installing and connecting the device 3.1 Preparing for installation 3.1.2.4 Installing a strain relief Requirements For mounting of the strain relief plate you need: ● The built-in device ● The strain relief plate from the scope of delivery ● Three M3 screws from the scope of delivery ●...
  • Page 42: Pro Devices

    Installing and connecting the device 3.1 Preparing for installation 3.1.3 PRO devices 3.1.3.1 Permitted mounting positions The device is intended for mounting on a support arm or stand. Position the device in such a manner that safety-related devices such as a mains isolation switch remain visible, accessible and operable.
  • Page 43: Transceiver Unit

    Installing and connecting the device 3.1 Preparing for installation 3.1.4 Transceiver Unit 3.1.4.1 Permissible mounting positions The following mounting positions are permissible for the Transceiver Unit: Mounting on the rear Mounting on one side The Transceiver Unit can be mounted on a DIN rail or on a wall using screws. The interfaces of the Transceiver Unit should always point downwards.
  • Page 44: Fastening The Mounting Rail

    Installing and connecting the device 3.1 Preparing for installation 3.1.4.3 Fastening the mounting rail Requirements To attach the mounting rail to the Transceiver Unit you need: ● The supplied mounting rail ● The supplied cross-tip cylinder head screw ● A torque screwdriver with cross-tip insert Procedure For attachment on DIN rail or on the wall, fasten the mounting rail in one of the lateral or rear guides in the...
  • Page 45: Installing The Built-In Unit

    Installing and connecting the device 3.2 Installing the built-in unit Installing the built-in unit 3.2.1 Notes on installation Before installing the device, please ensure that the installation location complies with the following: NOTICE Use according to IEC 61010-2-201 requires an appropriate enclosure The rear of the built-in device is classified as "Open Equipment"...
  • Page 46 Installing and connecting the device 3.2 Installing the built-in unit To achieve degree of protection IP65 for the built-in device, the mounting clips must be installed at the positions shown below. Device Positions of the mounting clips 15" built-in devices 19"...
  • Page 47: Fasten Built-In Device Using Mounting Clips

    Installing and connecting the device 3.2 Installing the built-in unit Device Positions of the mounting clips 24" built-in devices 3.2.3 Fasten built-in device using mounting clips Requirement ● All packaging components and protective films have been removed from the device. ●...
  • Page 48 Installing and connecting the device 3.2 Installing the built-in unit 1. Insert the device into the mounting cutout from the front. 2. Make sure that all four spring locks on the top and bottom of the device fully engage. If necessary, gently press the device into the recess if it is not fully engaged.
  • Page 49: Mounting The Pro Device

    Installing and connecting the device 3.3 Mounting the PRO device Mounting the PRO device 3.3.1 Notes on mounting WARNING The device must be mounted securely. Inadequately dimensioned fasteners may cause the device to fall down. Serious physical injury may result. Make sure that fasteners are adequately dimensioned during installation.
  • Page 50 Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the HMI device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
  • Page 51: Pro Devices For Support Arm (Not Extendable, Flange Top) And For Pedestal (Extendable, Flange Bottom)

    Requirement ● All packaging components and protective films have been removed. ● Siemens base adapter with screws, included in product package of a PRO device for support arm (not extendable, flange top) or for pedestal (extendable, flange bottom). ● One of the following support arms or pedestal systems: –...
  • Page 52 A device for a support arm system cannot be used on a pedestal, and vice versa. 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 53: Pro Devices For Support Arm (Extendable, Round Tube)

    The following figures show an example of how to attach the PRO device to a support arm system using the optionally available Siemens flange mount adapter. The same approach is used to mount the PRO device to a 48.3 mm round tube.
  • Page 54 3. Attach the flange mount adapter or the 48.3 mm round tube with the two M8 threaded pins. Observe the appropriate torque: – Siemens flange mount adapter: 8 Nm – 48.3 mm steel round tube 8 Nm – 48.3 mm aluminum round tube: 5 Nm...
  • Page 55 Installing and connecting the device 3.3 Mounting the PRO device 4. When you are using an adapter plate from a Siemens VESA adapter set, attach the adapter plate to the support arm with 4 M6x12 screws. When you are using another adapter plate matching the Siemens flange mount adapter, attach the adapter plate to the support arm with the supplied mounting hardware.
  • Page 56: Installing Transceiver Unit

    Important notes for installation • The device is approved for operation in closed rooms only. • For installation in a cabinet, read the manual "Installing control systems interference-proof (https://support.industry.siemens.com/cs/ww/en/view/59193566)" as well as the relevant DIN/VDE provisions and the applicable country-specific regulations. Requirements ●...
  • Page 57 Installing and connecting the device 3.4 Installing Transceiver Unit Wall mounting Fasten the Transceiver Unit to a wall with two M4 screws via the two elongated holes of the mounting rail. NOTICE Sufficient carrying capacity of the wall is required. If the wall does not have a sufficient load-bearing capacity, the device may fall and be damaged.
  • Page 58: Connecting The Device

    Installing and connecting the device 3.5 Connecting the device Connecting the device 3.5.1 Notes on connection Requirement ● The device has been installed according to the information provided in these operating instructions. Connecting cables Note Use copper cables at connectors with terminal connections Use copper (Cu) cables for all supply lines that are connected to the device with terminals, e.g.
  • Page 59 Installing and connecting the device 3.5 Connecting the device Connection sequence Connect the device in the following sequence: 1. Equipotential bonding (Page 60) 2. Power supply (Page 62) Perform a power-up test to ensure the power supply is connected with the correct polarity.
  • Page 60: Connecting The Equipotential Bonding Circuit

    Installing and connecting the device 3.5 Connecting the device 3.5.2 Connecting the equipotential bonding circuit Differences in electrical potential Differences in electrical potential can develop between spatially separate system components. Such electrical potential differences can lead to high equalizing currents across the data cables and therefore to the destruction of their interfaces.
  • Page 61 Installing and connecting the device 3.5 Connecting the device Wiring diagram The following figure shows the connection of the equipotential bonding using IFP1500 V2 as an example and similarly applies to the all Flat Panels and the Transceiver Unit. Note Cable routing for PRO devices As the PRO device is not installed in a control cabinet but on a pedestal or support arm, the connecting cables must be routed through the support arm or the pedestal.
  • Page 62: Connecting The Power Supply

    Installing and connecting the device 3.5 Connecting the device 3.5.3 Connecting the power supply Note before connecting the device NOTICE Safe electrical isolation Use only 24 V DC power supply units with safe electrical isolation in accordance with IEC 61010-2-201 or IEC 60950-1 in accordance with the SELV/PELV standard. The supply voltage must be within the specified voltage range.
  • Page 63 Each power supply line must be routed twice through the ferrite. The distance between the ferrite and the power supply connector must not exceed 200 mm. See also Designing interference-free controllers (https://support.industry.siemens.com/cs/ww/en/view/59193566) IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 64: Connecting The Ifp To A Pc

    Installing and connecting the device 3.5 Connecting the device 3.5.4 Connecting the IFP to a PC 3.5.4.1 Important notes for connecting The IFP is connected to a PC either directly or via the Transceiver Unit. The following applies: ● The video signal of the PC is transmitted to the IFP via the DisplayPort or DVI cable. ●...
  • Page 65: Connecting The Standard Version To A Pc

    Installing and connecting the device 3.5 Connecting the device 3.5.4.2 Connecting the standard version to a PC Connect a standard version directly to a PC via the following cables: ● DVI or DisplayPort cable, maximum length 5 m ● USB cable Type B connector - Type A connector, maximum length 5 m Wiring diagram The following figure shows an example of the direct connection of an IFP1500 V2 extended to an IPC427D and is generally valid for all standard versions in connection with a...
  • Page 66: Connect Extended Version Or Pro Device To Pc

    Installing and connecting the device 3.5 Connecting the device 3.5.4.3 Connect extended version or PRO device to PC Standard operation up to distance of 5 meters You can connect an extended version or a PRO device for distances of less than 5 m to the PC directly using the following cables: ●...
  • Page 67 Installing and connecting the device 3.5 Connecting the device Extended mode from 5 m to 100 m distance Connect an extended version or a PRO device for longer distances up to 100 m to the PC via the Transceiver Unit and the following cables: Connection of extended version or PRO device for Transceiver Unit ●...
  • Page 68 Installing and connecting the device 3.5 Connecting the device Note Possible number of extended versions or PRO devices on a PC A free USB interface and a free DisplayPort interface of the PC are required for each connection of an extended version or a PRO device to a PC via the Transceiver Unit. This means that the possible number of IFPs on a PC is defined by the number of available USB and DisplayPort interfaces of the PC.
  • Page 69: Connecting The Usb Device To The Ifp

    Installing and connecting the device 3.5 Connecting the device 3.5.5 Connecting the USB device to the IFP You can connect the following industry-standard IFP to the USB ports of the IFP: ● Mouse ● Keyboard ● USB storage media Note when connecting Note Use of USB devices •...
  • Page 70: Securing The Cables

    Installing and connecting the device 3.5 Connecting the device 3.5.6 Securing the cables 3.5.6.1 Securing cables at the IFP Use cable ties to secure the connected cables to the selected fixing elements for strain relief. Make sure that the cables are not crushed by the cable tie. The following figure shows an example of the fixing elements of a built-in device.
  • Page 71: Secure Cables At The Transceiver Unit

    Installing and connecting the device 3.5 Connecting the device 3.5.6.2 Secure cables at the Transceiver Unit The USB cable and the power supply cables connected to the Transceiver Unit must be secured using the supplied fastening elements. To install the fastening elements and secure the cables, proceed as follows: 1.
  • Page 72: Securing Cables For Use In Hazardous Areas

    Installing and connecting the device 3.5 Connecting the device 3.5.6.3 Securing cables for use in hazardous areas For securing the connected cables, use the appropriate mounting elements, as described in the previous chapter. When devices with Ex approval are used in hazardous areas, note that the connectors must be secured in a captive manner at the interfaces.
  • Page 73: Removing The Device

    Installing and connecting the device 3.6 Removing the device Removing the device This section describes how to remove the devices properly, when necessary. 3.6.1 Removing the built-in unit The built-in device is generally removed in the reverse order for mounting and connecting. Procedure Proceed as follows: 1.
  • Page 74: Removing Transceiver Unit

    Installing and connecting the device 3.6 Removing the device 3. Loosen the 8 screws of the backplane cover and remove the backplane cover. 4. Remove all cable ties used for strain relief on the strain relief plate of the PRO device. 5.
  • Page 75: Commissioning The Ifp

    Commissioning the IFP When you operate the IFP exclusively as monitor and do not change the brightness, you do not need to commission the device. To use extended functions, perform the following commissioning. Requirement ● The IFP is mounted according to the documentation. ●...
  • Page 76 Commissioning the IFP IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 77: Operating The Ifp

    Operating the IFP Operator input options Depending on the connected I/O devices, the following operator input options are available: ● Touch screen CAUTION Unintentional actions with touch screen operation If you touch the touch screen while system-internal processes are running, unintended reactions of the device may be triggered.
  • Page 78: Operating The Capacitive Multi-Touch Screen

    Operating the IFP 5.2 Operating the capacitive multi-touch screen Operating the capacitive multi-touch screen You operate the capacitive multi-touch screen with one or multiple fingers. You can also operate it using gestures with up to five fingers at a time. WARNING Personal injury or property damage due to no earth connection An inadequate ground connection or the lack of one may cause malfunction of the...
  • Page 79 Operating the IFP 5.2 Operating the capacitive multi-touch screen WARNING Danger of malfunctions due to incorrect execution of gestures on the touch screen If gestures are executed incorrectly on the touch screen with multi-touch function, these gestures may not be recognized or could be recognized incorrectly. The entries made are then not implemented by the touch device or are implemented incorrectly or in an unintended manner.
  • Page 80: Extended Functions

    Operating the IFP 5.3 Extended functions Functions of the capacitive multi-touch screen General functions ● Detection of up to 5 finger touches at a time. ● Detection of gestures that are supported by the operating system or the software installed on the PC.
  • Page 81: Maintaining And Servicing Your Device

    Maintaining and servicing your device General information on maintenance and servicing Observe the following when servicing and repairing protective equipment e.g. such as ground circuits or overvoltage protection components: ● Observe the maintenance and replacement intervals. ● Replace system components, including external cables, fuses and batteries only with equivalent components approved by the respective manufacturer.
  • Page 82: Spare Parts And Repairs

    Kraftwerkstraße 25a 91056 Erlangen Germany See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) Recycling and disposal The devices described in these operating instructions can be recycled thanks to their low level of pollutants. Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old devices, and dispose of the device according to the relevant regulations in your country.
  • Page 83: Technical Information

    ● 2014/34/EU "Equipment and protective systems intended for use in potentially explosive atmospheres" (Directive for Explosion Protection) EU Declarations of Conformity The EU Declarations of Conformity are available to the relevant authorities at the following address: Siemens AG Digital Industries Factory Automation DI FA AS SYS Postfach 1963...
  • Page 84 You can download information on the EC Declaration of Conformity, here under the keyword "Declaration of Conformity": ● IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) ● IFP PRO certificates (https://support.industry.siemens.com/cs/ww/en/ps/21662/cert) UL approval See the following notes: ● The device shall be supplied from an isolating source.
  • Page 85 You can find more information about explosion protection, EC/EU declarations of conformity and other certificates on the Internet at the following addresses: ● IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) ● IFP PRO certificates (https://support.industry.siemens.com/cs/ww/en/ps/21662/cert) Ex approval For an IFP with "Ex" marking, the following approvals apply according to the following standards ●...
  • Page 86 Technical information 7.1 Certificates and approvals IECEx approval For an IFP with "IECEx" marking, the following approvals apply according to the following standards. ● Standards: – IEC 60079-0:2011 – IEC 60079-15:2010 – IEC 60079-31:2013 ● Certifications and approvals: Ex nA IIC T4 Gc Ex tc IIIC T70°C Dc FCC and Canada Federal Communications...
  • Page 87 ● KR (Korean Register of Shipping) After acceptance has been granted, you can find the corresponding certificates on the Internet at the following addresses: ● IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) ● IFP PRO certificates (https://support.industry.siemens.com/cs/ww/en/ps/21662/cert) IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 88: Electromagnetic Compatibility

    EMC-compliant mounting of the device and the use of interference-proof cables provide the bases for trouble-free operation. Observed the following manuals in addition to these operating instructions: ● Designing interference-free controllers (https://support.industry.siemens.com/cs/ww/en/view/59193566) ● Industrial Ethernet/PROFINET – Passive network components (https://support.industry.siemens.com/cs/ww/en/view/84922825) Pulse-shaped disturbance The following table shows the electromagnetic compatibility of modules with regard to pulse- shaped interference.
  • Page 89 Technical information 7.2 Electromagnetic compatibility Sinusoidal interference The following table shows the EMC behavior of the modules with respect to sinusoidal interference. This requires the device to meet the specifications and directives for electrical installation. Sinusoidal interference Test values HF radiation (electromagnetic fields) 80% amplitude modulation at 1 kHz according to IEC 61000-4-3 to 10 V/m from 80 MHz to 1 GHz...
  • Page 90: Mechanical Environmental Conditions

    Technical information 7.3 Mechanical environmental conditions Mechanical environmental conditions 7.3.1 Storage conditions The following information is for a device that is transported and stored in its original packaging. The device was tested according to IEC 60721-3-2 Class 2M4 with the following additions and restrictions: Type of condition Permitted range...
  • Page 91: Climatic Ambient Conditions

    Technical information 7.4 Climatic ambient conditions Climatic ambient conditions 7.4.1 Long-term storage The following information applies to a device that is stored in its original packaging for longer than two weeks. The device meets the requirements according to IEC 60721-3-1 Class 1K21. 7.4.2 Transport and short-term storage The following information applies to a device that is transported in the original packaging and...
  • Page 92: Operating Conditions

    Technical information 7.4 Climatic ambient conditions 7.4.3 Operating Conditions The following information applies to a device installed according to the specifications in these operating instructions. The device is designed for weatherproof and stationary operation according to IEC 60721-3-3. The device meets the requirements according to IEC 60721-3-3 Class 3K3 with the following amendments and limitations: Type of condition Mounting position...
  • Page 93: 7.5 Information On Insulation Tests, Protection Class And Degree Of Protection

    Technical information 7.5 Information on insulation tests, protection class and degree of protection Information on insulation tests, protection class and degree of protection Insulation test The insulation resistance is verified by type testing with the following test voltages: Circuit Insulation tested with (type test) Rated voltage U 24 V 707 V DC to other circuits / to ground...
  • Page 94 Technical information 7.5 Information on insulation tests, protection class and degree of protection Protection from foreign objects and water PRO devices The device meets the requirements of IEC 60529 and UL50. Device side Degree of protection All-round IP65 according to IEC 60529 •...
  • Page 95: Dimension Drawings

    Technical information 7.6 Dimension drawings Dimension drawings 7.6.1 Dimension drawing of the IFP1500 V2 and IFP1500 V2 extended The following figures show the dimensions of the SIMATIC IFP1500 V2. The specified dimensions also apply to the SIMATIC IFP1500 V2 extended. IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 96: Dimension Drawing Of The Ifp1900 V2 And Ifp1900 V2 Extended

    Technical information 7.6 Dimension drawings 7.6.2 Dimension drawing of the IFP1900 V2 and IFP1900 V2 extended The following figures show the dimensions of the SIMATIC IFP1900 V2. The specified dimensions also apply to the SIMATIC IFP1900 V2 extended. IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 97: Dimension Drawing Of The Ifp2200 V2 And Ifp2200 V2 Extended

    Technical information 7.6 Dimension drawings 7.6.3 Dimension drawing of the IFP2200 V2 and IFP2200 V2 extended The following figures show the dimensions of the SIMATIC IFP2200 V2. The specified dimensions also apply to the SIMATIC IFP2200 V2 extended. IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 98: Dimension Drawing Of The Ifp2400 V2 And Ifp2400 V2 Extended

    Technical information 7.6 Dimension drawings 7.6.4 Dimension drawing of the IFP2400 V2 and IFP2400 V2 extended The following figures show the dimensions of the SIMATIC IFP2400 V2. The specified dimensions also apply to the SIMATIC IFP2400 V2 extended. IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 99: Dimension Drawing Of The Ifp1500 V2 Pro

    Technical information 7.6 Dimension drawings 7.6.5 Dimension drawing of the IFP1500 V2 PRO IFP1500 V2 PRO for pedestal (extendable, flange bottom) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 100 Technical information 7.6 Dimension drawings IFP1500 V2 PRO for support arm (not extendable, flange top) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 101 Technical information 7.6 Dimension drawings IFP1500 V2 PRO for support arm (extendable, round tube) ① With flange mount adapter ② Without flange mount adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 102: Dimension Drawing Of The Ifp1900 V2 Pro

    Technical information 7.6 Dimension drawings 7.6.6 Dimension drawing of the IFP1900 V2 PRO IFP1900 V2 PRO for pedestal (extendable, flange bottom) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 103 Technical information 7.6 Dimension drawings IFP1900 V2 PRO for support arm (not extendable, flange top) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 104 Technical information 7.6 Dimension drawings IFP1900 V2 PRO for support arm (extendable, round tube) ① With flange mount adapter ② Without flange mount adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 105: Dimension Drawing Of The Ifp2200 V2 Pro

    Technical information 7.6 Dimension drawings 7.6.7 Dimension drawing of the IFP2200 V2 PRO IFP2200 V2 PRO for pedestal (extendable, flange bottom) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 106 Technical information 7.6 Dimension drawings IFP2200 V2 PRO for support arm (not extendable, flange top) ① Without base adapter ② With base adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 107 Technical information 7.6 Dimension drawings IFP2200 V2 PRO for support arm (extendable, round tube) ① With flange mount adapter ② Without flange mount adapter IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 108: Dimension Drawing Of The Transceiver Unit

    Technical information 7.7 Rating plate 7.6.8 Dimension drawing of the Transceiver Unit The following figures show the dimensions of the Transceiver Unit with mounting rail. Rating plate The rating plate includes information that clearly identifies your device. You need this information when you contact Customer Support.
  • Page 109: Technical Specifications Of The Ifps

    Technical information 7.8 Technical specifications of the IFPs Technical specifications of the IFPs Weight of the built-in units 15" built-in devices 19" built-in devices 22" built-in devices 24" built-in devices Weight without packaging, with 3.3 kg 4.4 kg 5.8 kg 7.2 kg strain-relief plate Weight of the PRO devices for support arm (not extendable, flange top) and for pedestal (extendable,...
  • Page 110 Technical information 7.8 Technical specifications of the IFPs Input device 15" device 19" device 22" device 24" device Touch screen Yes, projective capacitive Interfaces Standard versions Extended versions and PRO devices DVI-D DisplayPort Yes, DisplayPort V1.2 USB Type A Yes, USB hub USB Type B, host RJ45 USB type A, maximum load 500 mA, equivalent to USB standard 2.0...
  • Page 111: Technical Specifications Of The Transceiver Unit

    Technical information 7.9 Technical specifications of the Transceiver Unit Technical specifications of the Transceiver Unit Weight Weight of the Transceiver Unit including fixing accessories 0.35 kg Interfaces DisplayPort USB Type B, host RJ45 DC power supply Rated voltage 24 V DC Permitted voltage range +19.2 V to +28.8 V Rated current...
  • Page 112: Dvi-D

    Technical information 7.10 Interface description 7.10.2 DVI-D DVI-D, 25-pin socket Name Meaning TMDS data2- DVI data output 2- TMDS data2+ DVI data output 2+ TMDS Data2 shield Cable shield DVI data output 2 Not assigned Not assigned DDC clock (SCL) Display Data Channel clock, bidirectional DDC data (SDA) Display Data Channel data, bidirectional...
  • Page 113: Displayport

    Technical information 7.10 Interface description 7.10.3 DisplayPort DisplayPort, 20-pin socket Name Meaning ML_Lane0+ DP data output 0+ Ground ML_Lane0- DP data output 0- ML_Lane1+ DP data output 1+ Ground ML_Lane1- DP data output 1- ML_Lane2+ DP data output 2+ Ground ML_Lane2- DP data output 2- ML_Lane3+...
  • Page 114: Usb Type B

    Technical information 7.10 Interface description 7.10.5 USB Type B USB Type B Name Meaning VBUS +5 V, fused Data channel, bidirectional Data channel, bidirectional Ground 7.10.6 RJ45 Interface to the Transceiver Unit, RJ45 socket Name Meaning Data output + Data output - Data output + Data output - Data output +...
  • Page 115: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 116 Technical Support A.1 Service and support IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 117: Markings And Symbols

    Markings and symbols Safety-relevant symbols The following table describes symbols that can be added to your SIMATIC device, to its packaging or to an enclosed document in addition to the symbols described in the manuals. Symbol Meaning Reference General danger sign Caution / Attention ISO 7000 No.
  • Page 118 Markings and symbols B.1 Safety-relevant symbols Symbol Meaning Reference Only for industrial applications and indoor areas (control cabinet) Install in control cabinet only Devices approved for Ex Zone 2 in a control cabinet with min. IP54 Devices approved for Ex Zone 22 in a control cabinet with min. IP6x IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 119: List Of Abbreviations

    List of abbreviations Alternating current ANSI American National Standards Institute BIOS Basic Input Output System Direct Current DisplayPort Digital Versatile Disk Digital Visual Interface Components and modules endangered by electrostatic discharge Electromagnetic compatibility Ground High Frequency Human Machine Interface Hot Plug Detect Industrial Flat Panel Ingress Protection Industrial PC...
  • Page 120 List of abbreviations IFP V2, IFP V2 PRO Operating Instructions, 08/2019, A5E46641410-AA...
  • Page 121: Glossary

    Glossary Application An application is a customer-specific system structure or software that is directly based on the operating system. One application on the PC/PG is STEP 7, for example. Display Component for visualization in a display device. In an operating and display device, the display behind the touch screen is integrated into the front of the device.