thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear
instructions
protective
gloves
1. Safety
1.1.
eleCtriCal Safety
Warning! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. sealey recommend that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
electrical safety information, it is important that the following information is read and understood.
1.1.1.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3.
important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
Do not pull or carry the appliance by the power cable.
8
Do not pull the plug from the socket by the cable.
8
Do not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
Warning! Before starting any repair, maintenance or cleaning always disconnect the power.
1.1.4.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
Working HeigHt
Warning! Must only be used correct height. log splitter must be securely mounted so that the hold-to-run two-hand control device
shall be located so that the height control actuators shall be between 850 mm to 1650 mm from the ground.
1.3.
Safety anD maintenanCe
Keep the log splitter clean for best and safest performance.
9
Maintain the log splitter in good condition (use an authorised service agent).
9
Prior to every use check all electrical connections, hydraulic pipes, hoses and safety / stopping devices.
9
Use a qualified person to lubricate and maintain the log splitter.
9
Do not use brake fluid to top up hydraulic unit.
8
Do not operate the log splitter if damaged.
8
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
1.4.
WorkSHop/enVironmental Safety
locate the log splitter on dry, level and solid ground in a suitable work area with adequate lighting. Fix securely in place using anchor
9
bolts.
Keep the area clean and tidy and free from unrelated materials. Do not leave tools, logs or other items lying around where they could
9
become a tripping hazard.
Do not operate the log splitter in wet or damp areas or expose it to rain.
8
Do not operate the log splitter in areas where fumes from paint, solvents, or flammable liquids pose a potential hazard.
8
1.5.
operator Safety
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.
9
Wear protective, electrically non conductive gloves.
9
Always wear safety goggles. everyday spectacles are not sufficient protection.
9
Maintain correct balance and footing, Do not over-reach. ensure the floor is not slippery and wear non-slip, protective footwear.
9
Do not allow untrained persons to operate the log splitter.
8
Do not operate the log splitter with the guards or guides removed.
8
© Jack sealey limited
4tonne Horizontal log Splitter 370mm CapaCity
5tonne log Splitter 520mm CapaCity
Model no's:
Wear eye
Wear ear
protection
protection
Original Language Version
lS370H.V2 & lS520H.V2
lS520HSt.V2
Wear
Wear safety
protective
footwear
clothing
lS370H.V2 LS520H.V2 Issue 2 (3) 02/10/19
Warning!
Warning!: No
reaching in.
area protect
recommended fuse rating
13 amp
Keep in dry
from rain

Advertisement

Table of Contents
loading

Summary of Contents for Sealey LS370H.V2

  • Page 1 Model no’s: lS520HSt.V2 thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    4tonne ls370H.V2 and 5tonnes ls520H.V2 of pressure. splits logs almost instantly upon contact, keeping labour and work time to a minimum. Features a two hand safety operation push-button and lever.
  • Page 3: Front Side

    Original Language Version © Jack sealey limited lS370H.V2 LS520H.V2 Issue 2 (3) 02/10/19...
  • Page 4: Operation

    Max pressure was set before the log splitter ex work and the max pressure limiting screw is sealed with glue to ensure the log splitter works under pressure no more than 4 tonnes (LS370H.V2) and 5tonnes (LS520H.V2). The setting was done by qualified mechanic with professional instruments.
  • Page 5: Maintenance

    6.1. replaCing HyDrauliC oil Replace the Hydraulic oil in the log splitter after every 150 hours of use with a good quality oil such as sealey HJo5ls. Take the following steps to replace it. Warning! Make sure all moving parts stop and the log splitter is unplugged.
  • Page 6: Troubleshooting

    9. introDuCtion Powder coated steel frame for added corrosion resistance. suitable for attaching Model no. ls520H.V2 and ls370H.V2 Horizontal log splitter. labour and work time are kept to a minimum by creating a suitable working height. Attaching the wheels from Model no. ls520H and ls370H enables easy and efficient movement of the stand.
  • Page 7 When assembling the frame you will be supplied with two different spacer bars use the one that is labelled for your splitter. Wheel Axle fig.27 fig.26 Original Language Version © Jack sealey limited lS370H.V2 LS520H.V2 Issue 2 (3) 02/10/19...
  • Page 8 Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey group, kempson Way, Suffolk business park, bury St edmunds, Suffolk. ip32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...