Page 2
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
Page 3
Attention-when the product is installed in Rack: For the customers in the Netherlands (For IXS-6600/IXS-6700) Voor de klanten in Nederland 1. Prevention against overloading of branch circuit Hoe u de batterijen moet verwijderen, leest u in de When this product is installed in a rack and is Onderhoudshandleiding.
Table of Contents Manual Structure 2. Service Information Purpose of this manual ..............3 2-1. Error Display ..............2-1 2-1-1. Front Panel Status ..........2-1 Related manuals ................3 2-1-2. Error Indications and Countermeasures ....2-4 Trademarks ................... 3 2-1-3. CA Board Error Display ........
This manual describes the protocol for controlling this unit. The manual below is provided for the protocol that this unit can support. If this manual is required, please contact your local Sony Sales Office/Service Center. SONY ROUTING SWITCHER SYSTEM REMOTE1 (S-BUS/ROT16) PROTOCOL and COMMAND SPECIFICATIONS Part No.: 9-977-477-xx...
Terminology . Routing Switcher Indicates the name of the product category. . Integrated Routing Switcher (IXS-6600/IXS-6700) This is the product name of IXS-6600/IXS-6700. The product category of the Integrated Routing Switcher belongs to Routing Switcher. . Routing Switcher System Indicates the configuration where multiple devices are connected to the Routing Switcher.
Section 1 Installation 1-1. Installation Procedure The following chart shows the procedure for installing the unit. For details of the following chart, refer to the relevant section or related manual. Start Selection of installation 1-2. Operating Environment place 1-3. Power Supply 1-4.
. Areas subject where is subjected to static electricity. 1-3-2. Recommended Power Cord Ventilation The inside of the IXS-6700-C/IXS-6600-C (IXS-6000 series hereafter) is cooled by a fan (both sides). . Use the approved Power Cord (3-core mains lead)/Appli- The power supply can be damaged if the exhaust vent ance Connector/Plug with earthing-contacts that conforms to the safety regulations of each country if applicable.
1-5. Installing the Options The IXS-6700-C/IXS-6600-C is shipped from the factory with the necessary option boards (refer to the following table) already installed in accordance with the specified system configuration. The usable optional board is different depending on the type of signal to handle.
Page 14
IXS-6700/IXS-6600 Option List The following options are available for the IXS-6700/IXS-6600. Model name Board configuration Plug-in board Connector board IKS-6030M MX-112 Board Matrix Board IKS-V6050M DVP-39A Board HD/SD Video Router Processor Board IKS-V6050SD DVP-39B Board SD Video Router Processor Board IKS-V6010M CNI-24A Board 16 HD/SD Digital Video Input Board...
1-5-1. Installing the Plug-in Boards Installation Procedure 1. Turn off the main power of this unit (IXS-6700 or IXS-6600) and disconnect the AC power cord from the Be sure to turn off the POWER switch before starting outlet. installation work. 2.
Page 16
4. Remove the fixing screws (IXS-6700: 7 screws, IXS- 5. While the eject levers are opened as shown in the 6600: 5 screws) and remove the Extract PWB stopper illustration, insert the plug-in board into the board assembly. guide rail. B3 x 5 Extract PWB stopper (The illustration shows...
1-5-2. Installing the Connector Board 6. While closing the eject levers in the direction of arrow 1, push in the plug-in board. 1. Remove the two screws and remove the blank panel. Store the removed blank panel in a safe place. B3 x 5 Blank panel B3 x 5...
1-5-3. Installing IKS-A6015 IXS-6700 option Name of option Name of board Slot on the rear side IKS-A6015 is used by being mounted on IKS-A6011 (CNI-26 board) or IKS-A6012 (CNI-28 board). IKS-V6010M CNI-24A board IN1 to IN8 IKS-V6060M CNO-26A board OUT1 to OUT8 1.
1-6. Rack Mounting 1-6-2. Rack Mounting Procedure This section describes the rack mounting procedure using The IXS-6700/IXS-6600 is mounted in the 19-inch standard the RMM-10 rack mount kit. rack. To mount the IXS-6700/IXS-6600 in the rack, use the specified rack mount kit and follow the procedure described 1.
Page 20
3. Loosen the screws on the rear of the right and left 7. Align the groove of the rack tools at the sides of the adapters and adjust the length of the adapter according equipment with the rail, and slide the equipment to the to the depth of the rack.
Use the following connectors and cables, or equivalents when connecting cables to the unit. Model name Panel indication Connector name Matching connector and cable Name Sony part No. IKS-6010M INPUT 1 to 16 BNC, 75 Z Belden 8281 coaxial IKS-6060M...
1-8. Input and Output Signals of ALARM (*1) : D-sub Mini 15-pin, Female Connectors The input and output signals of the connectors at the rear panel are as follows. _ EXT VIEW _ Pin No. Signal name Input/Output Function 1-8-1. IXS-6700, IXS-6600 ALARM-3 Alarm drive-3 ALARM-1...
1-8-2. IKS-A6011 REMOTE2/ALARM (* * * * * 2) : D-sub 9-pin, Female AES/EBU INPUT 1 to 12 : D-sub 37-pin, Female _ EXT VIEW _ When it is set as REMOTE2 _ EXT VIEW _ Pin No. Signal name Input/Output Function Frame ground...
Page 24
AES/EBU INPUT 13 to 24 : D-sub 37-pin, Female AES/EBU INPUT 25 to 32 : D-sub 25-pin, Female _ EXT VIEW _ _ EXT VIEW _ Pin No. Signal name Function Pin No. Signal name Function AES/EBU IN 13 (+) AES/EBU INPUT AES/EBU IN 25 (+) AES/EBU INPUT...
1-8-3. IKS-A6013 ANALOG AUDIO INPUT 5 to 8 : D-sub 25-pin, Female ANALOG AUDIO INPUT 1 to 4 : D-sub 25-pin, Female _ EXT VIEW _ Pin No. Signal name Function _ EXT VIEW _ ANALOG AUDIO ANALOG AUDIO IN 5 (+) INPUT Pin No.
Page 26
ANALOG AUDIO INPUT 9 to 12 : D-sub 25-pin, Female ANALOG AUDIO INPUT 13 to 16 : D-sub 25-pin, Female _ EXT VIEW _ _ EXT VIEW _ Pin No. Signal name Function Pin No. Signal name Function ANALOG AUDIO ANALOG AUDIO ANALOG AUDIO ANALOG AUDIO...
1-8-4. IKS-A6061 AES/EBU OUTPUT 13 to 24 : D-sub 37-pin, Female AES/EBU OUTPUT 1 to 12 : D-sub 37-pin, Female _ EXT VIEW _ _ EXT VIEW _ Pin No. Signal name Function AES/EBU OUT 13 (+) AES/EBU OUTPUT Pin No. Signal name Function AES/EBU OUT 13 (_)
AES/EBU OUTPUT 25 to 32 : D-sub 25-pin, Female Pin No. Signal name Function AES/EBU OUT 34 (+) AES/EBU OUTPUT AES/EBU OUT 34 (_) Ground _ EXT VIEW _ 1-8-5. IKS-A6063 Pin No. Signal name Function AES/EBU OUT 25 (+) AES/EBU OUTPUT ANALOG AUDIO OUTPUT 1 to 4 : D-sub 25-pin, Female AES/EBU OUT 25 (_)
Page 29
ANALOG AUDIO OUTPUT 5 to 8 : D-sub 25-pin, Female ANALOG AUDIO OUTPUT 9 to 12 : D-sub 25-pin, Female _ EXT VIEW _ _ EXT VIEW _ Pin No. Signal name Function Pin No. Signal name Function ANALOG AUDIO ANALOG AUDIO ANALOG AUDIO ANALOG AUDIO...
1-8-6. IKS-RS6010/IKS-RS6060 ANALOG AUDIO OUTPUT 13 to 16 : D-sub 25-pin, Female RS-422 INPUT 1 to 7 RS-422 OUTPUT 1 to : D-sub 9-pin, Female _ EXT VIEW _ Pin No. Signal name Function _ EXT VIEW _ ANALOG AUDIO ANALOG AUDIO When it is set as Master.
1-9. System Connection 1-9-1. S-BUS Data Link The routing switcher system is connected with the S-BUS data link using a 75 Z coaxial cable. The main equipment of the S-BUS data link is shown in the table below. Type in S-BUS Model (function name) Quantity Function/role...
Page 32
The connection example of the S-BUS data link using the IXS-6700 as the primary station is shown. The IXS-6700 does not have the control function of the monitoring S-BUS system. Maximum 16 equipment : S-BUS Terminal Terminal : Signal system line Personal computer Personal computer : Ethernet...
Page 33
Precautions for connection . For the controller and routing switcher that are used as the primary station, set the S/P selector switch on the CPU board (on the CA board for the IXS-6700/IXS-6600) to the “P” position. . For the controller and routing switcher that are used as the secondary station, set the M/S switch (S/P selector switch in the IXS-6700/IXS-6600) on the CPU board (on the CA board for the IXS-6700/IXS- 6600) to the “S”...
1-9-2. Network Connection Primary station Station ID = 1 IP(Main):192.168.0.10 IP(Backup):192.168.0.11 IP:192.168.0.5 Install the terminal emulator IXS-6700/IXS-6600 such as BZR-240R/BZR-20/ BZR-21 Ethernet REMOTE1 A NETWORK B NETWORK A Ethernet Ethernet switch Secondary station Station ID = 2 IP(Main):192.168.0.20 IP(Backup):192.168.0.21 Secondary station Ethernet NETWORK A Station ID = 4...
1-9-3. Synchronous Signal for the Audio Signal Synchronous signal to use and its setting When you are using the IKS-A6011/A6012/A6013/A6061/ A6062/A6063 (AES/EBU, ANALOG AUDIO input/output board), the synchronous signal is used in the following priority: 1. WORD SYNC IN terminal 2.
1-10. Setting the On-Board Switches and Description of LEDs The number shown in the parentheses ( ) indicates the address on the circuit board. 1. CA-65 board <IXS-6600/IXS-6700> D2215 D2214 D2208 D2201 D2217 D1801 S1201 S1204 D1102 S1202 D1103 D1104 D1315 S1203 D1203...
Page 37
D1103 (A-5): REM1 B TX D1320 (J-5) REMOTE1 connector S-BUS data send status indication Used only for production in the assembly factory. It turns Lights for a period of 0.015 seconds when the system sends off for normal operation. data to the data link through the REMOTE1 B1 or B2 D1504, D1503, D1502, D1501 (J-6): connector.
Page 38
S1201 (B-3): Station ID/ Unit ID setting switch S1202 (B-4) 8-pin DIP switch 8-pin DIP switch Factory setting (\ indicates the switch lever position.) Factory setting (\ indicates the switch lever position.) BIT1 : Virtual matrix function valid/invalid Sets the station ID of the IXS-6700/IXS-6600 when the selector switch IXS-6700/IXS-6600 is connected to the S-BUS data link as Set this switch when you want to use the virtual matrix...
Page 39
BIT4 : Unit ID/IP setting method selector switch BIT 8: USER-DEF switch Used to select the method of setting the IP address in the Used to select which setting to be enabled when the IXS- data link that is connected to the NETWORK connector. 6700/IXS-6600 is restarted.
Page 40
BIT2, BIT3: S/P selector switch S1204 (A-4) : Test rotary switch ..BIT2 : REMOTE1 A connector Run the system with 0 (default) position of this switch..BIT3 : REMOTE1 B, C (B1, B2, C) connectors Used to assign the IXS-6700/IXS-6600 either to the Be aware that if S1204 is set to 8 or 9, the information primary station or to the secondary station when the IXS-...
Page 41
IF-844 Board 6. 7 : Not used Factory use only (valid only during startup) <LED> Used for adjustment in the factory. If this mode is executed, all of the setting data are D1 (B-1): SRX deleted. Before executing this mode, implement the Lights in green about 0.015 second when it receives the backup of the setup data using the attached BZR-20 data from the S-BUS data link.
Page 43
D1100 (A-4) : FPGA2 D2003 (A-3) : + + + + + 12 +12 V power operation status indication. Operation status indication of FPGA2 (IC1100). Lights : Operation in progress. Lights : Operation in progress. Turns off : Operation not in progress. Turns off : Operation not in progress.
Page 44
3. DVP-39 Board <IKS-V6050M/SD> <LED> <Switch> D1 (A-3) : + + + + + 12 V_CTRL S1001 (A-11) : DIP SW Status indication of the +12 V power supply on the Used for production. Control CPU. Default setting when shipped from the factory is all OFF. Lights when the +12 V power on the control CPU is supplied.
Page 46
D1316 (A-5) : + + + + + 5 V +5 V power supply status indication. Lights when the +5 V power is supplied. When the +12 V power supply is not supplied either to the main or control CPU, this LED does not light. D1318 (A-4) : + + + + + 12 V_MAIN Status indication of the +12 V power supply on the main CPU.
Page 47
5. MX-112 Board S7402 D7417 D7418 D7419 S8101 S8001 D8001 D8302 D8303 D8301 D8202 D8203 D8201 S7401 CPU-DK3 <LED> D8001 (A-6) : RESET status LED D1 (A-3) : + + + + + 12 V control Indicates the RESET status on the MX-112 board. +12 V control status indication.
Page 48
D8202 (A-7) : DEBUG Ethernet LINK Lights when a link is established via CN8201 (DEBUG Ethernet). D8203 (A-7) : DEBUG Ethernet ACT Lights when transmission or reception is in progress via CN8201 (DEBUG Ethernet). D8301 (A-6) : Internal Ethernet speed 10 Mbps/100 Mbps Indicates whether the communication speed of Ethernet for unit internal communication is 10 Mbps or 100 Mbps.
1-11. Setting the IP Address 6. SG-281 Board <IXS-6600/IXS-6700> Setting the network connection (IP address) . If network setting is performed on the Main CPU board, D501 its values are automatically set in the backup CPU (CA- D502 D505 65) board. D504 .
Page 50
Setting procedure 1. Turn off the power of the IXS-6700/IXS-6600. 2. Connect the PC to the REMOTE3 connector. 3. Set the S1204 of the main CPU (CA-65) board to “E”. 4. Turn on the power of the IXS-6700/IXS-6600. 5. The following image is displayed on the PC screen. IP ADRS M = 192.168.0.135 IP ADRS B = 192.168.0.136...
Page 51
6. Move the cursor to the item to be set, and press “Enter”. The screen changes to the input mode. 7. Enter the necessary items. 8. Press “Enter” to terminate the setting. 9. Turn off the power and then back on. 10.
Section 2 Service Information 2-1. Error Display 2-1-1. Front Panel Status The current status of the unit can be displayed in the front panel. It is also possible to reset the elapsed time of display window through use of the operation buttons on the the power units and fan units.
To move to the next layer above Functions of the Operation Buttons Press the CANCEL button. To change the displayed item on the same layer Press the button. a MENU button b CANCEL button To return to the top display c ENTER button Press the MENU button.
Page 55
Press the button to select the item to be reset. PSU ELAPSED TIME: For resetting the elapsed time of the power unit FAN ELAPSED TIME: For resetting the elapsed time of the fan unit Press the ENTER button. The unit name appears on the second line of the display window.
2-1-2. Error Indications and Countermeasures This switcher performs self-diagnostics when you turn the The error code and ERROR No. shown in the status power on or press the reset button on the CPU board (CA- display on the CA-65 board also indicate errors. 65) that functions as the main board, as well as at regular You can easily determine the origin of an error through intervals during operation.
Page 57
Error Status You can display the error status in the display window. The error status is displayed in order of importance. Proceed as follows: The item for which the status is displayed can be changed by pressing the button. Press the MENU button to display the top display in the display window.
Page 58
c) The WORD SYNC IN terminal of the IXS-6600 is a single system, but distributed to two systems A and B inside. IXS-6600/6700...
2-1-3. CA Board Error Display CA board front display The front display located on the front of the CA board operates as follows when an error occurs or the warning status is established. . The STATUS indicator lamp of the CA board front display blinks in red (error) or in green (warning). .
Page 60
Status indication item Error code Error code Error symbol Error description E.27 SBUS S-BUS connection error The S-BUS line is disconnected. (detected by using or not using the 75 Z terminator.) E.40 Cross point error The presence or absence of the signal detected at the output terminal does not match at the specified cross point.
(1) Remove the front panel. (Refer to Section 1-5-1.) Cleaning of the fan every month is recommended. (2) Remove the dust accumulated on the filter with a Contact your local Sony Sales Office/Service Center for vacuum cleaner. information on cleaning the fan.
2-3. Lithium Battery A lithium battery is mounted on the CA-65 board for backing up RAM during power-off and for driving internal watch while the power is turned off. Replace the battery before the replacement time shown below comes. (For details on the procedures for replace- ment, refer to the maintenance manual.) Status of using IXS- Replacement time...
2-4. Data Backup The table data that are set from the personal computer (to be abbreviated as PC hereafter) are stored in the RAM on the CA-65 board. Backing up the stored data is recommended in the case of emergency such as data are damaged or lost.
2-4-2. Installing BZR-20/BZR-25 BZR-20/BZR-25 can be used in the IBM PC/AT compatible PC in which the Windows 2000 Professional or Windows XP Professional or Windows Vista Business of the Microsoft company is installed. Operating environment Hardware : IBM PC/AT compatible PC in which the Windows 2000 Professional or Windows XP Professional or Windows Vista Business is installed CPU : Operating clock 300 MHz or higher...
2-4-3. Uploading the Data Upload the various setup data of the system equipment from the primary stations to a PC. 1. Install the BZR-20 software. (Refer to Section 2-4-2.) 2. Turn on the power of all the equipment on the S-BUS data link. 3.
2-4-4. Downloading the Data Downloads the various setup data that are saved in a PC, to the system equipment through primary station. 1. Install the BZR-20 software. (Refer to Section 2-4-2.) 2. Connect the PC to the IXS-6700/IXS-6600 (or connect the PC to each equipment) and start up the BZR-20 software.
2-5. Troubleshooting The main power of the IXS-6700 cannot be turned The monitor picture is not displayed correctly. on. (Indicator does not light green.) A picture is not displayed on the monitor screen even The main power of the though the main power of IXS-6700 cannot be turned the IXS-6700/IXS-6600 is on.
Page 68
The audio signal is not displayed correctly. RS-422 IN/OUT does not operate correctly. Although the power to Although the power to IXS-6700/IXS-6600 is IXS-6700/IXS-6600 is turned on, the audio signal turned on, RS-422 IN/OUT is not output correctly. does not operate correctly. Install the standard boards Install the standard boards Are the standard boards...
Page 69
Appendix A Terminal No. Quick Reference List . As the maximum matrix size is different depending on the signal format, when the i/o connector board at the rear is inserted, the relationship between the slots and the terminal nos. Is different depending on the signal format. .
Page 70
AUDIO (D-SUB) AUDIO (D-SUB) Terminal number on Connector board Terminal number on Connector board Terminal number on Connector board Slot number SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SLOT10 SLOT11 SLOT12 SLOT13 SLOT14 SLOT15 SLOT16 AUDIO (BNC) AUDIO (BNC) Terminal number on Connector board Slot number SLOT1...
Page 71
ANALOG AUDIO RS-422 Numbers without parentheses indicate the display on the screen (Stereo pair = switching units) RS-422 Terminal number on Connector board Numbers within parentheses indicate the number for the signal name on the connector Slot number ANALOG AUDIO Terminal number on Connector board SLOT1 Slot number SLOT2...
Page 72
2. IXS-6600 system VIDEO VIDEO Terminal number on Connector board Slot number SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 AUDIO (D-SUB) AUDIO(D-SUB) Terminal number on Connector board Terminal number on Connector board Terminal number on Connector board Slot number SLOT1 SLOT2 SLOT3...
Page 73
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.