Term
FENA-21
FEPL
FIO-01
FIO-11
Four-quadrant operation
FPBA
Frame, frame size
FSCA
FSO-12, FSO-21
Generic enclosure
HTL
IGBT
Intermediate circuit
INU
Inverter
Inverter module
Inverter unit
Multidrive
NBRA
Parameter
PLC
RFI
SIL
STO
THD
TS 8
TTL
UPS
ZCON
ZCU
ZMU
Related documents
Manual
General manuals
ACS880 multidrive cabinets and modules safety instructions
ACS880 multidrive cabinets and modules electrical planning instructions
Drive modules cabinet design and construction instructions
BCU-02/12/22 control units hardware manual
Supply module manuals
Description
Optional Ethernet adapter module for EtherNet/IP™, Modbus TCP® and PROFINET
IO® protocols, 2-port
Optional Ethernet POWERLINK adapter module
Optional digital I/O extension module
Optional analog I/O extension module
Operation of a machine in both the forward and reverse directions in both motoring
and generating modes. Also used as an attribute of a drive; a regenerative drive can
operate the electric machine in all four modes, while a non-regenerative drive can
only operate the machine in motoring mode.
Optional PROFIBUS DP adapter module
Physical size of the drive or power module
Optional Modbus RTU adapter module
Optional functional safety modules
See chapter Ordering information.
High-threshold logic
Insulated gate bipolar transistor
DC circuit between rectifier and inverter
Inverter unit
Converts direct current and voltage to alternating current and voltage.
Inverter bridge, related components and drive DC link capacitors enclosed in a metal
frame or enclosure. Intended for cabinet installation.
Inverter module(s) under control of one control board, and related components. One
inverter unit typically controls one motor.
Drive for controlling several motors which are typically coupled to the same machinery.
Includes one supply unit, and one or several inverter units.
Series of optional brake chopper modules
In the drive control program, user-adjustable operation instruction to the drive, or signal
measured or calculated by the drive.
In some (for example fieldbus) contexts, a value that can be accessed as an object,
eg, variable, constant, or signal.
Programmable logic controller
Radio-frequency interference
Safety integrity level (1...3) (IEC 61508)
Safe torque off (IEC/EN 61800-5-2)
Total harmonic distortion
Enclosure system by Rittal (www.rittal.com)
Transistor-transistor logic
Uninterruptible power supply
Type of control board
Type of control unit
Type of memory unit, attached to the control unit
Introduction to the manual 19
Code
3AUA0000102301
3AUA0000102324
3AUA0000107668
3AUA0000113605