SHARP SERVICE MANUAL ELECTRIC WATER HEATER MODELS WH-236E WH-239EP WH-246E In the interests of user-safety (Required by safety regulations in some countries) the set should be restore to its original condition and only parts identical to those specifi ed should be used.
Page 2
ELB lamp Power lamp ELB button Heater lamp Power SW. button Water volume knob Shower hose Main water valve Breaker angle support SPECIFIC INFORMATION WH-236E WH-239EP WH-246E Model Rated voltage Rated frequency Power consumptions 3,500 4,500 Single point Water supply system...
However, if ELB light (green) still off, turn off this appliance by press the Power SW. button then contact your SHARP service facility or SHARP dealer. 9. Close supervision is necessary in order to check on the water temperature when used by children, elderly, patients and disabled person.
HOW TO USE BEFORE USE The installation work is to be done by the Authorized “SHARP” Dealer. The electric home shower unit must earthed. Special skill is required. Never try to repair the unit by yourself. 1. Open the main water valve from the home main water pipe.
WIRING DIAGRAM INSTALLATION ADVICE 1. BEFORE INSTALLATION Please check water pressure before operating this unit. Minimum water pressure : 0.02 MPa (0.21 Bar). Maximum water pressure : 0.34 MPa (3.39 Bar). Please follow the picture below to check water pressure. Water shall overfl ow at the end of the tube within 2.3 meters above the faucet.
Page 6
2.2. Removing the unit cover. Remove the screw underneath the unit. Open the cover by lifting from the bottom. Screw Fig. 8 2.3. Mounting the unit to the wall. Drill two 6 millimeters holes in the wall with approximately 25 millimeters in depth. Install wall anchors into the holes.
Page 7
2.5. The shower assembly. The joint the shower hose counterclockwise with the shower. Notifi cation in connecting the shower hose. Connect to the shower head. Shower head Connect to the unit. Joint Shower hose Fig. 12 2.6. Installation the shower stand. Ensure that the shower stand located in the level that the top part of the shower head is not higher than the top part of the unit when hanging the shower head.
Page 8
1. Be sure to cut off the main power supply switch every time before starting any electrical work Use dual insulated wire with at least 4 square meters cross-section (WH-236E, WH-239EP). Use dual insulated wire with at least 6 square meters cross-section (WH-246E).
3. The ground wire must be connected to grounding point on the unit. Grounding process. Ground rod installation, select the area where moisture stored in the soil and away from fl ood area with no sand or limestone. The diameter of ground rod is not less than 16 millimeters and the length is not less than 240 centimeters.
REPLACING METHOD FOR MAIN PARTS REMOVE OF SHOWER HOSE 1. Turn out the joint body between the body with the shower hose manually. Never use other tools to avoid breaking plastic parts. Body Shower hose Fig. 20 REMOVE OF BODY 1.
Page 11
REMOVE OF POWER SWITCH BUTTON 1. Remove the body in accordance with “REMOVE OF BODY”. 2. Push the claws of the guide pin by fl at screwdriver and remove the guide pin from the body. 3. Now the power SW. button is free. Body Guide pin Remove the guide pin...
Page 12
REMOVE OF TRIAC 1. Remove the body in accordance with “REMOVE OF BODY”. 2. Disconnect 3 lead wires from the triac. 3. Remove 2 screws holding to the heater tank ass’y. 4. Now the triac is free. White lead wire Breaker lead wire Brown lead wire Triac lead wire...
Page 13
REMOVE OF PCB-A 1. Remove the body in accordance with “REMOVE OF BODY”. 2. Pull out all the lead wires from the PCB-A. 3. Remove 3 screws holding the PCB-A. 4. Now the PCB-A is free. Screw PCB-A Back cover Fig.
Page 14
REMOVE OF BODY VALVE ASS’Y AND WATER OUTLET 1. Remove the body in accordance with “REMOVE OF BODY”. 2. Remove the reed SW. in accordance with “REMOVE OF REED SWITCH”. 3. Remove the push SW. set in accordance with “REMOVE OF PUSH SWITCH SET”. 4.
Page 15
REMOVE OF BREAKER 1. Remove the body in accordance with “REMOVE OF BODY”. 2. Remove split pin holding the breaker angle support to the breaker. 3. Remove 2 screws holding 2 breaker lead wires to the breaker. 4. Remove 2 screws holding the breaker to the back cover. 5.
TROUBLESHOOTING Problem Possible cause Corrective action Water is not hot. Power switch button is defected. Check or replace mechanical parts in - ELB lamp is not lights up. Power switch button. - Power lamp is not lights up. Check electrical leakage point from ELB breaker is cut off or defected.
SERVICE PARTS LIST Model WH-26E PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) PRINTING & PACKAGING MATERIAL 71M107 INSTRUCTION BOOK 71M100 SET PACKING CASE 71M101 CARTON BOX 71M102 NAME PLATE 71M104 WIRING DIAGRAM STICKER 71J105 LOWER PAD 71J106 UPPER PAD MECHANICAL PARTS 71M200SET BODY SET...
Page 19
PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) ELECTRIC PARTS 7A605 BREAKER 220V, 30A 71M402 PCB - A 71M409 LEAD WIRE FOR PCB - A CN2 71M403 PCB - B 71M411 BREAKER LEAD WIRE BLACK 7D2101 MICRO SWITCH 7R405 REED SWITCH ASS’Y 71M408 LEAD WIRE FOR PCB - A CN1 71J407...
Page 20
Model WH-239EP PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) PRINTING & PACKAGING MATERIAL 71M107 INSTRUCTION BOOK 71M120 SET PACKING CASE 71M121 CARTON BOX 71M122 NAME PLATE 71M104 WIRING DIAGRAM STICKER 71J105 LOWER PAD 71J106 UPPER PAD MECHANICAL PARTS 71M230SET BODY SET 71M231 TEMP.
Page 21
PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) ELECTRIC PARTS 7A605 BREAKER 220V, 30A 71M402 PCB - A 71M409 LEAD WIRE FOR PCB - A CN2 71M403 PCB - B 71M411 BREAKER LEAD WIRE BLACK 7D2101 MICRO SWITCH 7R405 REED SWITCH ASS’Y 71M408 LEAD WIRE FOR PCB - A CN1 71J407...
Page 22
Model WH-246E PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) PRINTING & PACKAGING MATERIAL 71M107 INSTRUCTION BOOK 71N100 SET PACKING CASE 71N101 CARTON BOX 71N102 NAME PLATE 71M104 WIRING DIAGRAM STICKER 71J105 LOWER PAD 71J106 UPPER PAD MECHANICAL PARTS 71N200SET BODY SET 71M211 TEMP.
Page 23
PARTS CODE REF. NO DESCRIPTION Q’TY PRICE (FEC) ELECTRIC PARTS 7A605 BREAKER 220V, 30A 71N402 PCB - A 71M409 LEAD WIRE FOR PCB - A CN2 71M403 PCB - B 71N411 BREAKER LEAD WIRE BLACK 7D2101 MICRO SWITCH 7R405 REED SWITCH ASS’Y 71N408 LEAD WIRE FOR PCB - A CN1 71K407...