Cisco PID
UCS-PSU-6332-DC
N9K-PUV-1200W
Figure 7: AC Power Supply for the Cisco UCS 6332 and UCS 6332-16UP Fabric Interconnect
Power supplies have two LEDs: one for power status and one for a failure condition.
1
LED
Power on LED
Power on LED
Power on LED
Fault/error LED
Fault/error LED
Fault/error LED
If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler panel
should be used to cover the empty slot.
Fabric Interconnect
Cisco UCS 6332 and
Cisco UCS 6332-16UP
Cisco UCS 6332 and
Cisco UCS 6332-16UP
Amber fault/error LED
State
Description
Solid green
Power supply is on and functioning properly
Blinking green
3.3 V voltage standby (VSB) is on but the power supply is not
powering the other units
Off
There is no AC power to the power supply
Solid amber
Power supply failure that indicates an over voltage, over current,
or over temperature
Blinking amber
AC power is present, 3.3 VSB is on, and the power supply is
off
Off
Normal operation