create policy (callhome)
• equipment-offline
• equipment-problem
• equipment-removed
• fru-problem
• health-led-amber
• health-led-amber-blinking
• identity-unestablishable
• inventory-failed
• license-graceperiod-expired
• limit-reached
• link-down
• management-services-failure
• management-services-unresponsive
• memory-error
• mgmtif-down
• ndisc-targets-config-error
• near-max-limit
• port-failed
• power-problem
• psu-insufficient
• psu-mixed-mode
• thermal-problem
• version-incompatible
• vif-ids-mismatch
• voltage-problem
Example
This example shows how to create, enter and enable a Call Home policy instance for link-down
events:
firepower # scope monitoring
firepower /monitoring # scope callhome
firepower /monitoring/callhome # enter policy link-down
firepower /monitoring/callhome/policy* # set admin-state enabled
firepower /monitoring/callhome/policy* # commit-buffer
Cisco Firepower 4100/9300 FXOS Command Reference
68