Section 5.1

Power Supply Specifications

The RUGGEDCOM M2200 can be equipped with the following power supplies:
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range.
Power Supply Type
24 VDC
48 VDC
d
HI (125/250 VDC)
d
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
Power Supply Specifications
Input Range
Minimum
Maximum
10 VDC
36 VDC
88 VDC
300 VDC
85 VAC
264 VAC
Internal Fuse Rating
36 VDC
6.3 A(F)
72 VDC
3.15 A(T)
2 A(T)
2 A(T)
Chapter 5
Technical Specifications
Maximum Power
ab
c
Consumption
28 W