hit counter script

Configuring The Table For Special Parts - Siemens COMOS Operating Manual

Life cycle engineering and plant asset management
Table of Contents

Advertisement

Configuring pipe specs
8.7 "Connector table" tab
Result
See also chapter Evaluation sequence (Page 103) or Example application in the engineering
data (Page 103).
8.7.3

Configuring the table for special parts

You are working in the table for special parts.
Requirement
You have assigned the following pipe spec elements to the pipe spec on the "Pipe parts" tab:
● The pipe parts (special parts) at whose connectors additional objects are to be added.
● The objects to be added at the connectors of the special parts.
Procedure
1. Open the context menu in the lower table and select "Add".
The "Select base object" window opens. The window contains a structure tree with the base
object of the pipe spec set as its start node. The pipe spec elements are displayed
underneath.
2. Select the pipe spec element you wish to register as the special part and close the window
by clicking the "OK" button.
A row for each connector of the pipe spec element is added to the table.
The name of the special component is displayed in the "Object" column in the row for the
first connector, and a link to the pipe spec element is entered.
3. Open the context menu in the "Definition applies" column in the row for the first connector
and select "Edit (F2)".
A list opens.
4. In the list, determine whether the definition is valid only for the pipe part drawn in the table
or for a certain function code range:
– "For current object" value: What matters here is not the function code, but the
– Values "71100" to "71XXX": The function code ranges
5. For each connector at which an additional object is to be added, proceed as follows:
– Open the context menu in the "Extra object" column in the row for the corresponding
– Select a pipe spec element.
6. Save your entries.
102
SystemUID of the base object.
connector and select "Edit (F2)".
All pipe spec elements whose connection type matches that of the connector on at least
one side are displayed.
A link to the pipe spec element is entered in the cell.
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents