SIEMENS MAINTENANCE MANUAL 1.0 SPECIFICATIONS This section provides dimensions/specifications of machines (VMCs 2216, 3016, 4020, 6030, 8030, 3020, 4525, and 6535). Dimensions represent in inches and millimeters. OCTOBER 2005 SPECIFICATIONS...
FADAL MACHINING CENTERS 1.1 ILLUSTRATIONS & DATA FOR ALL VMC MODELS 1.1.1 VMC 2216 Figure 1-1: VMC 2216 NOTE Dimensions represented in inches and [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 9
SIEMENS MAINTENANCE MANUAL Table 1-1: VMC 2216 Specifications 2216 SPECIFICATIONS 2216 STANDARD 2216 METRIC Table Size 39" x 16" 750 mm x 406 mm Floor to Table 31" 787 mm T-Slots (No. x Width x Span) 3 x .708" x 4.33"...
FADAL MACHINING CENTERS 1.1.2 VMC 3016 Figure 1-2: VMC 3016 NOTE Dimensions represented in inches and [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 11
SIEMENS MAINTENANCE MANUAL Table 1-2: VMC 3016 Specifications 3016 SPECIFICATIONS 3016 STANDARD 3016 METRIC Table Size 39" x 16" 750 mm x 406 mm Floor to Table 31" 787 mm T-Slots (No. x Width x Span) 3 x .708" x 4.33"...
FADAL MACHINING CENTERS 1.1.3 VMC 4020 Figure 1-3: VMC 4020 NOTE Dimensions represented in inches and [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 13
SIEMENS MAINTENANCE MANUAL Table 1-3: VMC 4020 Specifications 4020 SPECIFICATIONS 4020 STANDARD 4020 METRIC Table Size 48" x 20" 1,219mm x 508 mm Floor to Table 32" 813 mm T-Slots (No. x Width x Span) 5 x .708" x 3.74"...
Page 15
SIEMENS MAINTENANCE MANUAL Table 1-4: VMC 6030 Specifications 6030 SPECIFICATIONS 6030 STANDARD 6030 METRIC Table Size 62.5 x 30" 1,588mm x 762 mm Floor to Table 36" 914 mm T-Slots (No. x Width x Span) 5 x .708" x 5.512"...
Page 17
SIEMENS MAINTENANCE MANUAL Table 1-5: VMC 8030 Specifications 8030 SPECIFICATIONS 8030 STANDARD 8030 METRIC Table Size 82.5" x 30" 2,096 mm x 762 mm Floor to Table 36" 914 mm T-Slots (No. x Width x Span) 5 x .708" x 5.512"...
FADAL MACHINING CENTERS 1.1.6 VMC 3020 Figure 1-6: VMC 3020 NOTE Table and head shown at cold start position. Top of head cover at cold start position. Add 18” for max operating height. Subtract 2” for install height. Dimensions represented in inches & [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 19
SIEMENS MAINTENANCE MANUAL Table 1-6: VMC 3020 Specifications 3020 SPECIFICATIONS 3020 STANDARD 3020 METRIC Table Size 40.5" x 20" 1,029 mm x 508 mm Floor to Table 31" 787 mm T-Slots (No. x Width x Span) 5 x .708" x 3.74"...
FADAL MACHINING CENTERS 1.1.7 VMC 4525 Figure 1-7: VMC 4525 NOTE Table and head shown at cold start position. Top of head cover at cold start position. Add 18” for max operating height. Subtract 2” for install height. Dimensions represented in inches & [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 21
SIEMENS MAINTENANCE MANUAL Table 1-7: VMC 4525 Specifications 4525 SPECIFICATIONS 4525 STANDARD 4525 METRIC Table Size 53.5" x 25" 1,359mm x 635mm Floor to Table 31" 787mm T-Slots (No. x Width x Span) 5 x .708" x 4.92" 5 x 18mm x 125mm Cutting Feed Rate .01-400 ipm (600 ipm @ 150%)
FADAL MACHINING CENTERS 1.1.8 VMC 6535 SIDE VIEW FRONT VIEW TOP VIEW - BASE TOP VIEW Figure 1-8: VMC 6535 NOTE Dimensions represented in inches & [millimeters]. SPECIFICATIONS MAN-0126_R1...
Page 23
SIEMENS MAINTENANCE MANUAL Table 1-8: VMC 6535 Specifications 6535 SPECIFICATIONS 6535 STANDARD 6535 METRIC Table Size 74.8" x 26.5" 1,899mm x 673.1mm Floor to Table 40.3" 1024mm T-Slots (No. x Width x Span) 5 x .708" x 4.92" 5 x 18mm x 125mm Cutting Feed Rate .01-400 ipm (600 ipm @ 150%)
FADAL MACHINING CENTERS 1.2 FADAL BOLT TORQUE SPECIFICATIONS Table 1-9: Fadal Bolt Torque Specifications COMPONENT MODEL LOCATION BOLT SIZE TORQUE UNIT COLUMN COLUMN TO BASE 5/8"-11 X X.50 HHB FT-LBS COLUMN COUPLER SET SCREW 1/4"-20 X 0.50 SHSS IN-LBS COLUMN Z B/S MOUNT IN BACK 3/8"-16 X X.XX HHB FT-LBS...
FADAL MACHINING CENTERS 1.3 RECOMMENDED MAINLINE FUSES / Table 1-17: Circuit Breakers for the New Sheet Metal CIRCUIT BREAKERS SPINDLE 380-415 V 480 V TYPE 3 PHASE 3 PHASE 5 HP 10 HP 50 Taper 70 A SPECIFICATIONS MAN-0126_R1...
FADAL MACHINING CENTERS 2.1 FOUNDATION WARNING! The VMC MUST be placed on a surface that will support the combined weight of the VMC, options, fixtures, and tooling, etc. (refer to the VMC Specifications section at the beginning of this manual for VMC weights). 1.
Page 35
SIEMENS MAINTENANCE MANUAL Installation). For high performance machines, the machine must be bolted to achieve maximum performance. Figure 2-2: Anchor Stud Installation Table 2-1: Isolation Pad Dimensions MACHINE A (DEPTH) B (WIDTH) 2216/ 3016 7ft 9in 9ft 6in 4020 8ft 7in...
Page 36
FADAL MACHINING CENTERS 4. Use proper eye and hearing protection while performing this step. Remove dust and rubble from the hole with compressed air and brush. 5. Insert capsule in the hole, either end first. 6. Select proper 1/2” SQ. drive socket and attach to sup-r-setter. 7.
Page 37
SIEMENS MAINTENANCE MANUAL thicker with # 4 rebar 18” on center three inches off the ground. For stress lines in the concrete make sure they are such that they do not go under any of the machines. (If they do, this will eventually defeat the purpose of the pad.) The top of the felt, if used, should be sealed with a caulking compound to prevent oils and coolants from penetrating the ground.
SIEMENS MAINTENANCE MANUAL 2.3 POSITIONING 1. Place the VMC so that skylights or air vents are NOT directly overhead. Do not expose the machine to direct sunlight, or any other heat source. Do not place the machine in an area that will expose the machine to moisture, standing water, liquid or rain.
FADAL MACHINING CENTERS 2.4 AIR SUPPLY WARNING! Air pressure required: 120 psi before regulator, 80 psi after regulator, 15 scfm (stan- dard cubic feet per minute) momentary. 1. From the main air supply line attach a 3/8” air supply line for the VMC. The distance from the air compressor and number of machines attached should be taken into consideration when determining the size of piping for the main air supply line.
SIEMENS MAINTENANCE MANUAL 2.5 ELECTRICAL WARNING! GROUNDING The importance of proper grounding CANNOT be over-emphasized! Improper grounding will result in a wide range of hard-to-diagnose problems in communica- tions, positioning, spindle motion, etc. 1. The grounding conductor shall be of copper. The material selected shall be 2.5.1 PRIMARY...
Page 42
FADAL MACHINING CENTERS • intermediate metal conduit • electrical metallic tubing or cable armor 4. One end of the supplemental grounding conductor shall be attached to the VMC’s ground bus. The other end shall be effectively bonded to a copper cold water pipe that is in direct contact with the earth for 10 feet or more (See Figure 2-5: Bond Grounding Conductor to Copper Cold Water Pipe).
SIEMENS MAINTENANCE MANUAL 2.6 CHECKING GROUNDING INTEGRITY OF FADAL VMCS 1. MUST conferm to NEC code as stated in the Maintenance Manual. 2.6.1 SPECIFICATION - GROUNDING FOR THE FADAL MACHINE 2. MUST be a continuous wire 8 AWG or larger between the VMC's ground bus and the building power distribution panel serving the VMC.
FADAL MACHINING CENTERS 4. Turn off the VMC and measure the ground voltages (AC and DC) again. Record these readings. Voltages should be OV to .005V. 5. Voltages (AC or DC) across the ground wire will cause false resistance readings. If the ground voltages with VMC off are 0 (.005VAC max.), set meter to ohms and measure resistance between VMC ground bus and power distribution enclosure.
SIEMENS MAINTENANCE MANUAL 2.6.7 WIRING Table 2-5: Wiring Requirements 40 Taper 480 VAC 3 Ø 10 AWG (6 mm ) stranded 8 AWG (10 mm ) stranded THHN THHN copper within 100 ft. copper 100 ft. or more from panel.
FADAL MACHINING CENTERS 1. The number and size of conductors in any raceway shall not be more than will 2.6.8 CONDUIT permit dissipation of the heat. 2. The conduit must allow ready installation or withdrawal of the conductors without damage to the conductors or to their insulation. Table 2-6: Conduit Selection # OF CONDUCTOR SIZE...
SIEMENS MAINTENANCE MANUAL 3.0 INSTALLATION PROCEDURE WARNING! Before beginning the Machine Installation & Hook-Up it is important to review the entire Installation Procedure section. OCTOBER 2005 INSTALLATION PROCEDURE...
FADAL MACHINING CENTERS 3.1 MACHINE INSTALLATION & HOOK-UP Tools Required 3.1.1 UNPACKING Hammer, 15/16” socket or wrench and knife 1. Remove the crate and/or protective material from around the VMC. 2. Remove the strapping material from the front doors. 3. Unload the boxes from the inside and/or around the VMC. 4.
SIEMENS MAINTENANCE MANUAL 3. At this point the VMC is ready for power and air connections. Hole provided for 1-1/4” bar minimum bar length 36” 1-8”eye bolt 2 places 1.5” eye bolt 2 places for 6535 Maximum fork width is 6.00”...
(ST-26), 5/16” hex bit socket and 3/4” open or box wrench. Verify the Main Power Fuses Siemens requires 3 phase power. Voltage must be 400 or 480 Volts (depending on Module). The voltage differences between each lug and ground (measured at incoming terminal) must be less than 5%.
Page 51
SIEMENS MAINTENANCE MANUAL Verify the MOV Surge Suppressor Board 1. Locate the MOV Surge Suppressor Board (see Figure 3-2: MOV Surge Suppressor Board). Figure 3-2: MOV Surge Suppressor Board 2. Find the part number on the board. a. If your incoming voltage is over 380 VAC, then PCB-0146 should be installed.
SIEMENS MAINTENANCE MANUAL 3.2 TRANSFORMER 1. With the machine main power switch turned OFF, verify that the chart on the door of TAPPING the cabinet is the one for the transformer in the machine. 2. Measure the input voltage to the machine on the chart (Measure leg to leg the input power lines to the machine.).
FADAL MACHINING CENTERS 3.3 PHASE The normal Fadal VMC requires three phase-input power. Some customers prefer to CONVERTER ROTARY use rotary phase converters. However, Fadal does not recommend the use of rotary phase converters. Rotary phase converters input single-phase 208 to 230 VAC and output three phase 230 VAC.
SIEMENS MAINTENANCE MANUAL 3.4 LEVELING Leveling is an important first step in setting up the VMC. All calibration and squareness performed on the assembly line is done with the machine leveled. It is important to follow the sequence below precisely to ensure proper results.
Page 58
FADAL MACHINING CENTERS 8. Place the level on the right hand way (the outer right hand way on the 6535) of the base with the small bubble towards the column. Take an accurate reading. (See Figure 3-8: Leveling Box Way.) Figure 3-8: Leveling Box Way.
Page 59
SIEMENS MAINTENANCE MANUAL 13. Verify the spindle tram and, if necessary, adjust by slightly changing only the two front leveling screws. OCTOBER 2005 INSTALLATION PROCEDURE...
FADAL MACHINING CENTERS 3.5 HOLD DOWN Larger machines may vibrate, bump on reversals, and degrade floor finish. CLAMPS This may indicate that the base casting needs to be clamped to floor. Larger machines need to be clamped to the floor to prevent movement between the machine and the floor, and clamping holes are provided on all base castings for this purpose.
SIEMENS MAINTENANCE MANUAL 3.6 OPTICAL FIBER Careful handling of Optical Fiber Cable: CABLE HANDLING 1. Even though reinforcing cover used on the optical fiber code has enough mechani- cal strength, be sure not to be damaged by heavy materials drop.
FADAL MACHINING CENTERS 3.7 COUPLER NOTE Motor and Ball Screw shaft must be clean and oil free. INSTALLATION ON AXIS MOTOR OR Follow the next procedure: BALLSCREW 1. Loosen both coupler HUB screws. 2. Mark coupler HUBs and SPIDER before disassembling to insure coupler is assem- bled back together the same way.
Page 63
SIEMENS MAINTENANCE MANUAL 6. Install the SPIDER and set the tolerance on all 4 RAISED BOSSes to 0.015”-0.030” from the HUB using 2 (two) 0.015”(0.381mm) and 0.030” (0.762mm) feeler gages. Figure 3-10: Gages 7. Install Ball Screw coupler HUB on the SPIDER and set the tolerance on all 4 RAISED BOSSes to 0.015 “...
Page 64
FADAL MACHINING CENTERS Table 3-1: Couplers MACHINE X AXIS Y AXIS Z AXIS 2216 KTR ROTEX GS24 KTR ROTEX GS24 KTR ROTEX AI GS24 .625x24mm .625x24mm .625x19mm 3016 3020 4020 4525 6030 8030 Z-AXIS 19ft X-AXIS 8ft Y-AXIS 8ft Figure 3-12: Motors Table 3-2: Couplers MACHINE X AXIS...
SIEMENS MAINTENANCE MANUAL 3.8 PENDANT In order to install pendant, follow the next procedure: INSTALLATION VMC 6535 1. Carefully remove shipping crate, with pendant inside, from machine and place it close to the right side of the machine. 2. Remove second (smaller) box from the machine.
FADAL MACHINING CENTERS 3.9 GENERAL Detach column breaks from spindle head and tool changer arm. side view Column breaks front view Figure 3-13: Column breaks Place the cable carrier (black flexible arc on top of the machine) onto appropriate screws and tight them with nuts. Figure 3-14: Cable carrier INSTALLATION PROCEDURE MAN-0126_R1...
SIEMENS MAINTENANCE MANUAL 3.10 CHIP CONVEYOR 1. Place the chip conveyor in the coolant tank. 3.10.1 INSTALLATION PROCEDURE 2. Measure the height to the top of the conveyor sheet metal (should be approximately the height of the coolant tank). 3. Set the machine height (the machine should be on the small leveling pads) to slightly above the height established in step 2 above.
FADAL MACHINING CENTERS 7. Adjust the machine height (during leveling and installation) to minimize the gap (or overlap) between the coolant tank face and the machine sheet metal, (Figure 3-17: Minimize Gap of Overlap). Figure 3-17: Minimize Gap or Overlap 8.
Page 69
SIEMENS MAINTENANCE MANUAL 2. The control also has a variable speed control for the belt speed. The belt speed can be controlled from 2.60 ft./min. to 10.80ft/min. Figure 3-18: Control Operating Positions Figure 3-19: Emergency Stop (CE machines only) OCTOBER 2005...
FADAL MACHINING CENTERS 4.1 SCHEDULED MAINTENANCE Daily 4.1.1 MAINTENANCE & LUBRICATION SCHEDULE 1. Check air pressure: Right regulator 120 psi. max. (Tool Out Only). Left Regulator 80-90 psi. 2. Check way lube level. Use Castrol Magna BD68, Shell Tonna 68V or Mobil Vactra #2 ONLY.
SIEMENS MAINTENANCE MANUAL 10. Grease Geneva wheel and gear using Kopr-Kote. 11. For high torque machines, check fluid level in the hydraulic actuator reservoir. Refill, if needed, with Mobil DTE Heavy Medium. 12. Inspect all cooling fans, clean screens if necessary.
FADAL MACHINING CENTERS 3. Remove the oil line that is between the way lube pump and the three port junction T that is located near the pump mount. 4. Verify that the flush pump air regulator is fully counterclockwise. 5. Attach an air line to the flush pump. WARNING! Verify that the air regulator is closed.
SIEMENS MAINTENANCE MANUAL WARNING! Wear safety glasses! If the fan is turning slowly or not at all, it may require cleaning or replacement. The fan on the bottom of the junction box has a screen that requires periodic inspection and removal for cleaning.
FADAL MACHINING CENTERS The tank reservoir is located next to the motor pump assembly in the chiller cabinet. 4.1.6 TANK RESERVOIR The tank has a 2 1/2 gallon capacity. Visually check the fluid level with the machine powered on. If the fluid level is less than 1/2 of the tank, mix the DOWFROST™ to a 50:50 solution, with deionized water, or sodium free distilled water and fill to no more than 3/4 full.
SIEMENS MAINTENANCE MANUAL 4.1.7 FLUIDS Table 4-1: Fluids RESERVOIR FILL WITH Waylube CASTROL MAGNA BD68 SHELL TONNA 68V or MOBIL VACTRA #2 Spindle Cooling System DOWFROST™ CLEAR (Mixed 50/50 with de-ionized water or sodium free distilled water) Rotary Tables MOBIL GEAR 626...
FADAL MACHINING CENTERS The causes of abnormal wear and fractures will be apparent when the tool changer is 4.1.8 DUAL ARM TOOL CHANGER used without lubricant. It is very important to grease all moving parts of the tool changer at least once a week. Lubricant The lubricant should be changed annually, or when it has become visibly deteriorated.
Page 79
SIEMENS MAINTENANCE MANUAL 2. Inspection: a. Check the parts of the tool falling mechanism for damage and wear. Add grease to the sliding base of the tool falling mechanism and the pull rod. b. Check the parts of the tool pots, tool discs, and snap rings for damage and tightness.
FADAL MACHINING CENTERS 4.2 TESTS FOR CE These tests should be done when machine is first installed and after servicing when SAFEGUARDS ON any components are replaced. FADAL MACHINES 1. Power on machine but do reference. Start spindle. (Press Shift-Spindle on) •...
Page 81
SIEMENS MAINTENANCE MANUAL Daily & Weekly Safety Tests for CE Safety Circuits To ensure proper functioning of safety circuits, the following tests should be performed on a regular basis. Daily Front Door Lock Daily Test for 2030-OA 1. Close all doors. Make sure machine is not in emergency stop.
FADAL MACHINING CENTERS 4.3 CHIP CONVEYOR Please carry out daily, monthly, and yearly inspection according to the following 4.3.1 MAINTENANCE SCHEDULE CHIP directions. CONVEYOR Daily Inspection 1. Always keep oil in the speed reducer at the specified oil level. 2. Check motor for abnormal operation, i.e. noise, heat excessive current, etc. 3.
SIEMENS MAINTENANCE MANUAL 1. At the initial running, confirm the following before turning power on. a. Inspect for and remove any article other than material (chip, etc.) to be trans- ported on conveyor link belt portion. WARNING! Make sure hands, feet and clothing are clear of all moving parts.
Page 84
FADAL MACHINING CENTERS Figure 4-3: Adjust Take-Up Bearing 3. Check roller chain between motor and conveyor for proper alignment and correct tension. Figure 4-4: Check Roller Chain 4. The greatest care should be exercised to keep friction surface of torque limiter free from oil when lubricating roller chain.
FADAL MACHINING CENTERS 5.1 HELPFUL FORMULAS Degrees Fahrenheit (F) = (9/5 x degrees C) + 32 5.1.1 TEMPERATURE Degrees Celsius (C) = 5/9 x (degrees F-32) Inch (in) = millimeter x 0.03937 5.1.2 CONVERSION FACTORS Inch (in) = centimeter x 0.3937 Millimeter (mm) = inch x 25.4 Centimeter (cm) = inch x 2.54 Liter = gallon (U.S.) x 3.7854...
FADAL MACHINING CENTERS 5.2 THERMAL EXPANSION Thermal expansion is a natural occurrence in materials subject to heat, and there are 5.2.1 OVERVIEW several sources of heat in any machining operation. In addition, different materials react to heat at different rates, and different subsystems of the VMC react to specific machining operations to different degrees, further complicating matters.
SIEMENS MAINTENANCE MANUAL It comes as no surprise that the primary source of heat in machining is friction; however, 5.2.5 HEAT SOURCES some of the sources of friction, and all of the areas affected by a given friction source, may not be readily apparent. Additionally, the effects on the ambient temperature from various heat sources in the machine shop are often overlooked.
Page 90
FADAL MACHINING CENTERS of carrying away the heat of the cut and minimizing the effects of thermal expansion resulting from that heat. Yet another practice that deserves mentioning is machining parts at temperatures significantly different from those at which the parts are inspected. If the inherent expansion of the part material from the heat of the machining process is outside tolerance once the part has cooled to inspection temperatures, the problem can only be resolved by correcting for the heat generated during machining so as to keep the part...
SIEMENS MAINTENANCE MANUAL 5.3 NON-UNIFORM EXPANSION The differing rates of expansion by unlike materials further complicate the problems 5.3.1 MATERIAL DIF- FERENCES created by the heat generated in the machining process. This applies both to parts stock, like aluminum, and to fixtures and sub plates, often also made of a material like aluminum.
Page 92
FADAL MACHINING CENTERS on the table. Because of its large size, the table seems less affected by the heat of machining. It will expand, but it takes longer to heat or cool the entire table. In addition, the use of coolant tends to stabilize the temperature of the table at or close to coolant temperature.
SIEMENS MAINTENANCE MANUAL 5.4 SOLVING THE THERMAL EXPANSION PROBLEM A simplified description of the thermal environment in machining would state that heat 5.4.1 GENERAL CON- SIDERATIONS is generated through friction, and also input through ambient factors. That heat is transferred among the system components, and is either removed from the system through radiation, convection and evaporation, or absorbed by the components of the system (part, fixture, VMC).
FADAL MACHINING CENTERS 5.5 READING STATUS Reading a status in a computer can be very helpful for troubleshooting. Status is GROUP usually a byte or a word. The status is normally represented in hexadecimal. To demonstrate how a status byte is decoded, the command 1 byte in the diagnostics – display switches will be used.
SIEMENS MAINTENANCE MANUAL 5.6 VMC MAINTENANCE The fans in the cabinets must be functioning properly. The purpose of the fans in the 5.6.1 CABINET FANS cabinets is to cool the electronics and to move the heat out the vents. An excessive amount of heat in the cabinets, from clogged holes or nonfunctional fans, will transfer to the column and cause it to expand, as well as damaging the electronics.
Page 96
FADAL MACHINING CENTERS This process is also effective for inspecting parts. By cooling the part prior to the finish cuts, the temperatures at final cut and at inspection can be brought closer. In this situation, the target temperature should also be close to the temperature at which the gauge is calibrated.
SIEMENS MAINTENANCE MANUAL There are options that can be added to a standard VMC to help manage the thermal 5.6.4 VMC OPTIONS expansion problems. Probe A probe in the spindle can be used as a part of the program to discover what adjustments are required to compensate for thermal expansion.
FADAL MACHINING CENTERS Thermal expansion is a natural occurrence in any machining operation, and, when 5.6.5 CONCLUSION ignored, can significantly impact positioning repeatability. By identifying and eliminating unwanted heat sources, by calculating or measuring expansion effects and altering positioning accordingly, by performing regular maintenance on the VMC, and by adopting the machining practices outlined above, the effects of thermal expansion can be reduced.
SIEMENS MAINTENANCE MANUAL INDEX 2216 & 3016 TABLE 19 3020 & 4525 TABLE 20 4020 TABLE 21 6030 TABLE 22 6535 TABLE 24 8030 TABLE 23 ACCURACY AND REPEATABILITY 82 AIR SUPPLY 34 AIR SUPPLY 43 ALTERNATE SERVICE 38 AMBIENT SOURCES 87...
Page 100
FADAL MACHINING CENTERS GENERAL 60 GENERAL CONSIDERATIONS 87 GENERAL INFORMATION 79 HEAT SOURCES 83 HELPFUL FORMULAS 80 HOLD DOWN CLAMPS 54 ILLUSTRATIONS & DATA FOR ALL VMC MODELS 2 INSPECTION - CHECK GROUND WIRE COMING INTO VMC 37 INSTALLATION PROCEDURE 41 INSTALLATION PROCEDURE 61 LEVELING 51 LUBRICATION 89...
Page 101
SIEMENS MAINTENANCE MANUAL RESTARTING THE CHIP CONVEYOR 77 SCHEDULED MAINTENANCE 66 SCHEDULED MAINTENANCE FOR DUAL ARM TOOL CHANGER 72 SHIPPING DIMENSIONS 32 SOLVING THE THERMAL EXPANSION PROBLEM 87 SPECIFICATION -GROUNDING FOR THE FADAL MACHINE 37 SPECIFICATIONS 1 SPINDLE & BALLSCREW COOLING SYSTEM 69...
Page 102
FADAL MACHINING CENTERS INDEX MAN-0126_ R1...