hit counter script
Dell SCv2000 Getting Started Manual
Dell SCv2000 Getting Started Manual

Dell SCv2000 Getting Started Manual

Storage center
Hide thumbs Also See for SCv2000:

Advertisement

Dell Storage Center
SCv2000 and SCv2020 Storage System
Getting Started Guide
Regulatory Model: E09J, E10J
Regulatory Type: E09J001, E10J001

Advertisement

Table of Contents
loading

Summary of Contents for Dell SCv2000

  • Page 1 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001...
  • Page 2: Notes, Cautions, And Warnings

    WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2016 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
  • Page 3: Setting Up The Storage System

    Consider the following best practices when setting up an SCv2000/SCv2020 storage system. • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system. • Complete the Worksheet to Record System Information in this guide before configuring the storage system.
  • Page 4 WARNING: Installing an incompatible battery may increase the risk of fire or explosion. Observe the following precautions: • The battery should only be replaced with a battery that is the same or equivalent as the factory installed battery. • Do not attempt to open or service the battery. Do not dispose of the battery in a fire or with household waste.
  • Page 5: Worksheet To Record System Information

    Worksheet to Record System Information Use the following worksheet to record the information that is needed to install the SCv2000/SCv2020 storage system. Storage Center Information Gather and record the following information about the Storage Center network and the administrator user.
  • Page 6: Iscsi Fault Domain Information

    This information is needed to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard. NOTE: For a storage system deployed with two Ethernet switches, Dell recommends setting up each fault domain on separate subnets.
  • Page 7: Additional Storage Center Information

    The Network Time Protocol (NTP) and Simple Mail Transfer Protocol (SMTP) server information is optional. The proxy server information is also optional, but it may be required to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard. Table 5. NTP, SMTP, and Proxy Servers NTP server IPv4 address ___ .
  • Page 8 (4-port I/O card only) Physical WWN of storage controller ________________ 1: port 3 (4-port I/O card only) Physical WWN of storage controller ________________ 2: port 3 Table 7. Virtual WWNs in Fault Domain 1 Virtual WWN of storage controller 1: port 1 ________________ Virtual WWN of storage controller 2: port 1 ________________...
  • Page 9: Locating Your Service Tag

    You can find the service tag and Express Service Code on the service luggage tag located next to the front panel display. Alternatively, the information may be on a sticker on the back of the storage system chassis. Dell uses this information to route support calls to the appropriate personnel.
  • Page 10: Installation And Configuration

    Rack rails (2) Front bezel Installing the Storage System in a Rack Install the SCv2000/SCv2020 storage system and other Storage Center system components in a rack. NOTE: Mount the storage system in a manner that allows for expansion in the rack and prevents the rack from becoming top‐heavy.
  • Page 11 a. Lift the locking tab on the rail. b. Push the rail towards the back of the chassis until it locks in place. Determine where to mount the storage system in the rack and mark the location at the front and rear of the rack. NOTE: The storage system and expansion enclosures each require 2U of rack space for installation.
  • Page 12: Installing The Front Bezel

    Tighten the screws to secure the chassis into the rack. c. Close the latch on each chassis ear. For more information about installing the storage system, see the Dell Storage Center SCv2000/SCv2020 Storage System Deployment Guide If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack.
  • Page 13: Connecting The Power Cables

    Figure 5. Front Bezel Insert the left end of the bezel into the securing slot until the release latch snaps into place. Secure the bezel with the keylock. Connecting the Power Cables Connect the power cables to the storage system. Before connecting the power cables, make sure that the power switches on the storage system are in the OFF position.
  • Page 14: Nom Information (Mexico Only)

    50/60 Hz Current 7.6–3.0 A consumption Technical Specifications The technical specifications for the SCv2000/SCv2020 storage systems are shown in the following tables. Drives SAS hard drives SCv2000: Up to 12 3.5-inch SAS hot-swappable hard drives (6.0 Gbps), six drive minimum SCv2020: Up to 24 2.5-inch SAS hot-swappable hard drives...
  • Page 15 Configurations Storage Center supports up to 168 drives in one redundant- path SAS chain • The SCv2000 supports up to 13 SC100 expansion enclosures or 6 SC120 expansion enclosures. • The SCv2020 supports up to 12 SC100 expansion enclosures or 6 SC120 expansion enclosures.
  • Page 16 AC power supply (per power supply) Wattage 580 W (maximum wattage: 584 W) Voltage 100–240 VAC (7.6–3.0 A) Heat dissipation SCv2000: 65 W at 230 VAC and 99 W at 115 VAC SCv2020: 65 W at 230 VAC and 99 W at 115 VAC...
  • Page 17 Up to 0.5 A at +12 V Physical Height 8.79 cm (3.46 in.) Width 48.2 cm (18.98 in.) Depth SCv2000: 57.6 cm (22.67 in.) SCv2020: 52.3 cm (20.59 in.) Weight (maximum SCv2000: 28.9 kg (63.9 lb) configuration) SCv2020: 24 kg (53 lb) Weight without drives SCv2000: 20.6 kg (45.4 lb)
  • Page 18 Environmental Storage –40°C to 65°C (–40°F to 149°F) at a maximum altitude of 12,000 m (39,370 ft) Relative humidity Operating 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point Storage 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point Maximum vibration Operating...

This manual is also suitable for:

Scv2020

Table of Contents