Performing a Nozzle Check
Related topics
Disposing of Used Consumables and Optional Parts
Replacing the Head Cleaning Set
Replace the head cleaning set when you see a message on the LCD screen.
Note: The printer warns you when the head cleaning set is running low. The printer warning system may
not function properly if you do not follow the correct procedure for replacing the head cleaning set.
1. Turn on the printer.
2. Press the
The Maintenance menu appears.
3. Press the up or down arrow button to select Head Cleaning Set, and press the right arrow button to
select it.
4. Press the right arrow button again.
5. Press the up or down arrow button to select Yes, and press the OK button.
The platen and print head move to the maintenance position.
Caution: Do not move the print head or the platen manually. A malfunction may occur.
Note: A buzzer sounds after 10 minutes once the platen and print head move to the maintenance
position. Press the OK button to continue cleaning. The buzzer sounds again after 10 minutes.
Nozzles can be clogged if more time passes, so finish cleaning as soon as possible.
6. Replace the parts of the head cleaning set in the following order:
• Wiper unit
• Anti-drying caps
• Flushing pad
Replacing the Wiper Unit and Anti-drying Caps
Replacing the Flushing Pad
Parent topic:
maintenance button.
Maintenance
113